Gas Filter Correlation CO Analyzer E PA The Model 300E measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. This is accomplished with a Gas Filter wheel which alternately allows a high energy light source to pass through a CO filled chamber and a chamber with no CO present. The light path then travels Standard two year warranty through the sample cell, which has a folded path of 14 meters. The energy loss through the sample cell is compared Ranges, 0-1 ppm to 0-1000 ppm, user selectable Gas Filter Wheel for CO specific measurement 14 meter path length for sensitivity with the span reference signal provided by the gas filter to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and a high signal to noise ratio allowing extreme sensitivity. Microprocessor controlled for versatility Multi-tasking software allows viewing of test variables during operation Multi-tasking software gives real time indication of numerous operating parameters and provides automatic alarms if diagnostic limits are exceeded. Built-in data Continuous self checking with alarms acquisition and internal memory allows logging multiple Bi-directional RS-232 for remote operation parameters including average and instantaneous values, Digital status outputs indicate instrument operating condition calibration data and operating parameters. Stored data Adaptive signal filtering optimizes response time Ethernet port via our APIcom software or from the front GFC wheel guaranteed against leaks for 5 years diagnostics and enhanced data analysis by tracking are easily retrieved through the serial port or optional panel, allowing operators to perform predictive parameter trends. Temperature & Pressure compensation Internal data logging with 1 min to 365 day multiple averages The Model 300E features rugged construction and is designed to perform with a minimum of attention. In the event maintenance is required, modular construction APIcom remote operation software makes service a simple operation. FREE Customer Support by telephone and email for the life of the instrument
Open the catalog to page 1Gas Filter Correlation CO Analyzer Specifications Ranges: 0-1 ppm to 0-1,000 ppm full scale, user selectable. Dual ranges and auto ranging supported Dimensions (HxWxD): Zero Noise: Analog Outputs: Span Noise: Recorder Offset: Serial Outputs: Serial Port 1: RS-232 (DB-9M) Serial Port 2: standard RS-232 or optional RS-485 (DB-9F), Ethernet Status (Digital): 8 outputs, 6 inputs (opto-isolated), 4 alarm outputs (optional) Lower Detectable Limit (LDL): 0.04 ppm Zero Drift: Span Drift: Rise and Fall Time: Current Output: Optional 4-20mA, select up to three channels USEPA RFCA-1093-093, MCERTS...
Open the catalog to page 2All Teledyne API catalogs and technical brochures
-
T200
2 Pages
-
T108
2 Pages
-
T102
2 Pages
-
T101
2 Pages
-
T100H
2 Pages
-
CAT-O3 Series
2 Pages
-
SCI-552
2 Pages
-
OG-5000 Series
2 Pages
-
Model ODS
2 Pages
-
Mini ODS
2 Pages
-
T SERIES_BROCHURE_2018
6 Pages
-
Model dFFOZ-TR
2 Pages
-
The Model T200P
2 Pages
-
Model 651
2 Pages
-
T640
4 Pages
-
T Series Instruments
6 Pages
-
The Model T703
2 Pages
-
NumaView software
4 Pages
-
The Model T640
4 Pages
-
452
2 Pages
-
465H
2 Pages
-
465M
2 Pages
-
Model 702
2 Pages
-
Model T204
2 Pages
-
Model T700H
2 Pages
-
Model 751H
2 Pages
-
Model 751
2 Pages
-
T701H
2 Pages
-
T701
2 Pages
-
T750
2 Pages
-
CAPS NO 2 Analyzer
4 Pages
-
T500U
2 Pages
-
T750U
2 Pages
-
Model 602 BetaPLUS
4 Pages
-
Calibrators T700U
2 Pages
Archived catalogs
-
Calibrators T700
2 Pages
-
T Series
6 Pages
-
Total Sulfur Analyzer
2 Pages
-
UV Fluorescence SO2 Analyzer
2 Pages