1. Catalogs
  2. Teledyne Analytical Instruments
  3. Series LXT Smart Transmitter

Series LXT Smart Transmitter

Series LXT Smart Transmitter

Series LXT Smart Transmitter

Product catalog summary
Overview: The document provides detailed information about the LXT-220 model from Teledyne Analytical Instruments, focusing on its capabilities for on-line analysis of various parameters such as pH, ORP, conductivity, resistivity, and dissolved oxygen. It highlights the advanced features, flexibility, and applications of the LXT-220 and related models.
Specifications: The LXT-220 features a unique systems bus architecture for robust functional flexibility. It includes a graphics display for enhanced visualization and flexible calibration. The model supports multiple process measurements including pH, ORP, conductivity, resistivity, and ISE, with temperature compensation tailored to application requirements.
Process Controller: The LXT-220 can handle up to four sensor inputs and six output functions, with field-configurable relay outputs for process needs. It supports temperature PID and process variable outputs, offering complete configuration flexibility.
Diagnostics and Communication: The LXT-220 can be upgraded with pre-fault diagnostics and Hart communications to alert operators of potential electrode failures. These upgrades must be requested at purchase.
Smart Transmitters: The LXT-230 and LXT-280 are microprocessor-based, loop-powered transmitters designed for simple liquid measurement and control. They are available in watertight configurations and can be quickly installed and calibrated.
Durability and Cost Efficiency: The LXT-230 and LXT-280 feature rugged enclosures for field use, with modular designs for easy upgrades and maintenance. They are designed to resist moisture, dust, and chemicals.
Applications: The instruments are used in various industries, including power, pulp and paper, water treatment, food and beverage, and pharmaceuticals, for tasks such as monitoring heat exchanger leaks, controlling boiler feedwater, and monitoring conductivity in clean-in-place processes.
Sensor Design: The SP-1 and SP-2 sensors offer modular construction for easy installation and maintenance, with features like integral preamplifiers and temperature compensation modules. They are designed for high accuracy and reliability in aggressive environments.
Technical Specifications: The document provides detailed technical specifications for measurement ranges, accuracy, operating temperatures, and sensor mounting options. It also includes warranty information and contact details for Teledyne Analytical Instruments.
See more

Catalog excerpts

Series LXT Smart Transmitter-1

TELEDYNE ANALYTICAL INSTRUMENTS On line analysis of pH, ORP, PION, DO Conductivity & Resistivity Liquid Analytics made simple

 Open the catalog to page 1
Series LXT Smart Transmitter-2

Advanced, Flexible and Versatile Controllers AC Powered The LXT-220’s unique systems bus architecture design allows for incredibly robust functional flexibility. Graphics Display Allows any of the resident parameters (input, output, control, temperature, etc.) to be graphed on the display with the operator selecting both the sensitivity and time base of the graphing function. In addition to the enhanced visualization of the process or control dynamics, the graphics display allows a much more flexible approach to calibration, diagnostic and set-up procedures. Process Measurements Conductivity...

 Open the catalog to page 2
Series LXT Smart Transmitter-3

Sensors that offer an Extra Measure of Performance TAI’s state-of-the-art, modular SP-1 insertion/immersion and SP-2 valve-retractable sensors lend adaptability to the entire line of process measurements - including pH, dissolved oxygen (DO), conductivity, resistivity, ORP and Pion - and provide an extra measure of accuracy, dependability, safety and cost efficiency. Modular Construction You never experience downtime with the SP-1 and SP-2 analytical sensors. Low profile, modular construction allows easier installation, field service and factory upgrades. And with fewer, interchangeable spare...

 Open the catalog to page 3
Series LXT Smart Transmitter-4

Series LXT Smart Transmitter Specifications LXT-220 4-20 mA Hart; up to 6 analog outputs Power requirements Recommended 24 VDC, maximum 50 VDC, minimum 15 VDC Maximum loop impedance 500 ohms on 4-20 mA outputs with internal 24 VDC Menu driven Supertwist LCD. Simultaneously displays process ID, Process value in Eng units, percent output and temperature in °C or °F Menu driven Supertwist LCD. Simultaneously displays process ID, Process value in Eng units, percent output and temperature in °C or °F Menu driven Supertwist high temp LCD. Rotates 90° for best viewing. Simultaneously displays process...

 Open the catalog to page 4

All Teledyne Analytical Instruments catalogs and technical brochures

  1. PEM 9004

    4  Pages

  2. INSTA TRACE

    2  Pages

  3. PHOTO-X

    6  Pages

  4. MODEL MAX5

    2  Pages

  5. 9110T Series

    4  Pages

  6. 9060Z

    4  Pages

  7. 8800 series

    6  Pages

  8. 1220

    4  Pages

  9. SERIES 6700

    6  Pages

  10. model 9070

    2  Pages

  11. MODEL 3010TA

    2  Pages

  12. 3000TA-XL

    2  Pages

  13. BDS series

    4  Pages

  14. 3020T

    2  Pages

  15. 3000TB

    2  Pages

  16. R-15

    1  Page

  17. UFO-130-2

    2  Pages

  18. T-7

    1  Page

  19. R-22MED

    1  Page

  20. R-17MED

    1  Page

  21. PEM-9004

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.