Series 4060 Overview The Teledyne Analytical Instruments (TAI) Series 4060 speciates gases of interest by combining well-accepted gas chromatography techniques with TAI's f ield-proven detector technologies. This combination, along with effective electrometer-based signal amplification and temperature control, enables the Series 4060 to detect either single or multiple compounds in a background gas possessing potentially interfering compounds. Gas Chromatography Gas Chromatography Column Component separation is achieved using an appropriate packed column. The column consists of a suitable length...
Open the catalog to page 24060 SERIES - GAS CHROMATOGRAPHS Sample Handling System Optimal control of temperature and flow rates for the column, detector and sample handling components is critical for stable, repeatable readings. The Model 4060 sample system is sealed and insulated, utilizing PID controllers to ensure the ultimate temperature stability of the switching valve and column/detector compartment. Tubing, fittings and components within the sample system are 300-series stainless steel and Teflon. 4060A TCD Rack-Mount Analysis Compartment The carrier gas and other applicable utility gases are regulated using miniature...
Open the catalog to page 34060 SERIES - GAS CHROMATOGRAPHS Detector Technologies Flame-Ionization Detector (FID) Because of its high sensitivity to most organic compounds, the flame ionization detector is a powerful tool for measuring hydrocarbon impurities in gases. It also provides a linear response over a wide range of analysis. Figure A shows the general construction of an FID. Organic compounds from the sample stream or separation column are injected into the detector housing where they are mixed with Hydrogen and air before entering the detector jet where the mixture is burned. During this process, organic compounds...
Open the catalog to page 4Features • Field-proven microprocessor-based electronics provide menu-driven functionality • Easy-to-view 5-digit LED display for readings • 2x20 vacuum fluorescent display for menu options, settings, and status • Built-in diagnostic capability • EEPROM to store factory defaults in the event of loss of power • Ready for auto-calibration and remote-calibration with external solenoid valves (integral cal valves available as option) • Automatic flame ignition / re-ignition and flame-out guard circuitry (for FID detector) • Methanizer available with FID version for detection of carbon monoxide and...
Open the catalog to page 54060 SERIES - GAS CHROMATOGRAPHS Teledyne Tracs™ Diagnostic Software Tracs™ software developed by TAI is a unique program to unveil chromatogram and compound retention sequences on which concentrations of compounds of interest are calculated. It provides valuable access for an ordinary user to look into inside the complicated GC world with a computerized tool. It suits the needs for high accuracy in GC technique and for ease of communication in digital format. Bi-directional communication of analyzer’s range, alarm and timing settings which can be remotely uploaded and downloaded Acquires real-time...
Open the catalog to page 6.TELEDYNE ANALYTICAL INSTRUMENTS A Teledyne Technologies Company 16830 Chestnut Street City of Industry, CA 91748, USA TEL: (626) 934-1500 or (888) 789-8168 FAX: (626) 934-1651 E-MAIL: [email protected] www.teledyne-ai.com Warranty Instrument is warranted for one year against defects in material or workmanship NOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. All specifications and features are subject to change without notice.
Open the catalog to page 84 Pages
2 Pages
6 Pages
2 Pages
2 Pages
4 Pages
4 Pages
2 Pages
6 Pages
4 Pages
4 Pages
6 Pages
4 Pages
2 Pages
2 Pages
2 Pages
4 Pages
4 Pages
2 Pages
2 Pages
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
4 Pages
4 Pages
2 Pages