PEM 9004

PEM 9004

PEM 9004

Product catalog summary
Overview: The PEM 9004 is a portable emissions analyzer designed to detect and calculate up to ten gas parameters. It features a lightweight, robust case with an integral sample pump and a microprocessor-based system for easy operation.
Features:
  • IP67 rated waterproof and chemical-resistant case.
  • Rechargeable battery with up to 40 hours of continuous use.
  • Thermal printer with easy paper loading.
  • Large back-lit LCD display for up to ten readings.
  • Electronic functions: hold, min/max, zoom, search, unit conversion.
  • Various gas and pressure measurement units.
  • Selectable fuel type for calculations.
  • Self-diagnostics for sensors and USB data interface.
  • Certified to EN 50379-2.
Measured Parameters:
  • Oxygen (O2)
  • Carbon Monoxide (CO) (H2-compensated)
  • Nitrogen Oxide (NO) - optional
  • Sulfur Dioxide (SO2) - optional
  • Flue gas temperature
  • Ambient temperature
  • Differential temperature
  • Differential pressure
Calculated Parameters:
  • Carbon Dioxide (CO2)
  • NOx
  • CO – undiluted
  • Boiler efficiency (Eta)
  • Waste gas losses (qA)
  • Excess air value (Lambda)
Gas Measurements:
  • Oxygen (O2): 0-25% vol, 0.1% resolution.
  • Carbon Monoxide (CO): 0-4,000 ppm vol, optional high range 0-20,000 ppm, 1 ppm resolution.
  • Nitrogen Oxide (NO): 0-2,000 ppm vol, 1 ppm resolution.
  • Sulfur Dioxide (SO2): 0-2,000 ppm vol, 1 ppm resolution.
Temperature Measurements:
  • Flue Gas: 0°C to 1000°C, 1°C resolution, Type K thermocouple.
  • Ambient: -20°C to 100°C, 0.1°C resolution, Type K thermocouple.
Pressure Measurement:
  • Differential pressure: ±130 mbar, 0.01 hPa resolution.
Technical Specifications:
  • Probe material: 316SS, standard length 300mm, other lengths available.
  • Weight: Approx. 3 kg.
  • Dimensions: 275mm W x 115mm H x 250mm D.
Maintenance Advice: Replace the Teflon membrane and Infiltec fine filter as needed. It is recommended to keep a stock of these spares.
Warranty: Sensors are warranted for 1 year against defects in material or workmanship.
Contact Information: Teledyne Analytical Instruments, City of Industry, California, USA. Tel: 626-934-1500 or 888-789-8168. Email: [email protected]. Website: www.teledyne-ai.com.
See more

Catalog excerpts

PEM 9004-1

TELEDYNE Analytical Instruments A Teledyne Technologies Company Portable Emissions Analyzer

 Open the catalog to page 1
PEM 9004-2

The PEM 9004 is a stack gas analyzer capable of detecting and calculating up to ten (10) gas parameters, housed in a lightweight and robust case. An integral sample pump draws a sample through the included 316SS probe and gas treatment system built in to the case. The analyzer utilizes microprocessor-based electronics with a back-lit LCD display and membrane panel to provide easy-to-view readings and navigation of functions. Features • IP67 rated waterproof and chemical resistant case with vent valve • Rechargeable battery with up to 40 hours continuous use (adapter included) • Thermal printer...

 Open the catalog to page 2
PEM 9004-3

INSERTION PROBE Carbon Monoxide (CO) Measurement Range: 0-4,000 ppm vol (H2 - compensated) Optional high range: 0-20,000 ppm nitrogen Oxide (No) Measurement - Optional Range: 0-2,000 ppm vol sulfur Dioxide (sO2) Measurement - Optional Range: 0-2,000 ppm vol TEMpERATuRE MEASuREMENTS Flue Gas temperature Range: Resolution: Thermocouple: ambient temperature Range: Resolution: Thermocouple: pressure measurement Differential pressure Range: ±130 mbar calculated gas measurements Calculated Carbon Dioxide (CO2) Range: 0 to CO2 max vol parameter other lengths available Thermocouple: K-type...

 Open the catalog to page 3
PEM 9004-4

Warranty Sensors are warranted for 1 year against defects in material or worksmanship. NOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be constructed as test criteria for every product. All specifications and features are subject to change without notice. TELEDYNE Analytical Instruments A Teledyne Technologies Com-16830 Chestnut Street City of Industry, California 91748, USA Tel: 626-934-1500 or 888-789-8168 Fax: 626-934-1651 Email: [email protected] Website: www.teledyne-ai.com ©2008 Teledyne Analytical Instruments,...

 Open the catalog to page 4

All Teledyne Analytical Instruments catalogs and technical brochures

  1. INSTA TRACE

    2  Pages

  2. PHOTO-X

    6  Pages

  3. MODEL MAX5

    2  Pages

  4. 9110T Series

    4  Pages

  5. 9060Z

    4  Pages

  6. 8800 series

    6  Pages

  7. 1220

    4  Pages

  8. SERIES 6700

    6  Pages

  9. model 9070

    2  Pages

  10. MODEL 3010TA

    2  Pages

  11. 3000TA-XL

    2  Pages

  12. BDS series

    4  Pages

  13. 3020T

    2  Pages

  14. 3000TB

    2  Pages

  15. R-15

    1  Page

  16. UFO-130-2

    2  Pages

  17. T-7

    1  Page

  18. R-22MED

    1  Page

  19. R-17MED

    1  Page

  20. PEM-9004

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.