1. Catalogs
  2. Teledyne Analytical Instruments
  3. Model InstaTrans (3001) Oxygen Transmitter

Model InstaTrans (3001) Oxygen Transmitter

Model InstaTrans (3001) Oxygen Transmitter

Model InstaTrans (3001) Oxygen Transmitter

Product catalog summary
Overview: The InstaTrans Oxygen Transmitter by Teledyne Analytical Instruments is designed for detecting trace and percent levels of oxygen in various processes. It combines flexibility, ease of use, quick recovery, reliability, and cost-effectiveness.
Flexibility: The device is a two-wire, loop-powered 4-20 mA transmitter housed in a weather-tight NEMA-4 enclosure. It can switch between ppm and percent oxygen detection by changing the sensor and resetting the range scale. It offers six selectable ranges from 0-10 ppm to 0-25% and can be equipped with stainless steel or nylon wetted parts.
Ease of Use: The transmitter features a built-in meter for visual feedback, confirming operations like range changes and span calibration. It includes six function keypads for easy operation without needing a manual, and the keypad is UV and EMI resistant.
Insta Trace Technology: Teledyne's patented Insta Trace technology significantly reduces the recovery time when changing sensors, allowing meaningful results in minutes instead of hours. This technology ensures quick and reliable analysis, saving time and money.
Intrinsically Safe Design: The InstaTrans can be used in both non-hazardous and hazardous environments, with intrinsic safety barriers required for Division 1 locations. It is certified for use in Class I, Division 1, Groups A, B, C, & D hazardous areas.
Features: The transmitter includes a digital display, intuitive controls, easy calibration, weather-tight construction, reverse voltage protection, and digital electronic control circuitry. Options include the Insta Trace sensor for ppm applications and intrinsically safe operation.
Applications: Suitable for petrochemical process control, natural gas transmission, chemical feedstock purity analysis, air separation, inert gas analysis, heat treating, gas purity certification, nuclear fuel processing, quality assurance, and flue gas analysis.
Specifications: The transmitter offers trace ranges from 0-10 to 0-1000 ppm and percent ranges from 0-1 to 0-25%. It features a NEMA 4 rated enclosure, operates between 32 – 122°F, and has a response time of less than 40 seconds for the 0-10 ppm range. It requires 9.3 – 30 vDC and weighs 7.04 lb.
Warranty: The instrument is warranted for one year against defects in material or workmanship.
See more

Catalog excerpts

Model InstaTrans (3001) Oxygen Transmitter-1

TELEDYNE ANALYTICAL INSTRUMENTS Trace and Percent Oxygen Transmitter

 Open the catalog to page 1
Model InstaTrans (3001) Oxygen Transmitter-2

eledyne has redefined the ease and simplicity of detecting either ppm or percent levels of oxygen in a process with a single device – the INSTA TRANS™ O2 transmitter. By applying lessons learned from our Series 300T & 300P intrinsically safe oxygen transmitter designs introduced in the late 1980s, and adding parameters required by today’s users, the Insta Trans offers unprecedented: • Quick recovery on ppm O2 applications (when changing out sensors) Cost effectiveness FLEXIBILITY The Insta Trans is a two-wire, loop-powered 4-20 mA oxygen transmitter packaged within a weather tight NEMA4 housing....

 Open the catalog to page 2
Model InstaTrans (3001) Oxygen Transmitter-3

INTRINSICALLY SAFE DESIGN The Insta Trans can be used in a general purpose, nonhazardous environment or a hazardous area. When used in Division 1 or equivalent hazardous / classified locations, the Insta Trans must be installed in conjunction with optional intrinsic safety barriers. The Insta Trans is designed as instrinsically safe for use in Class I, Division 1, Groups A, B, C, & D hazardous areas or EExiaIICT4 (60°C), and certified by Factory Mutual and BASEEFA. The Insta Trans is self-certified by Teledyne as suitable for Class I, Division 2 areas without the use of I/S barriers utilizing...

 Open the catalog to page 3
Model InstaTrans (3001) Oxygen Transmitter-4

InstaTrans Oxygen Transmitter SPECIFICATIONS Ranges: % of range; 4-20 mADC non-isolated (power loop) Wetted parts: 316 stainless steel, viton o-ring, gold and nylon contact plate ±1% of full scale for all ranges at constant temperature NEMA 4 rated stainless steel and aluminum Operating temp: Response time: (10 – 90% @ 1.8 SPLM @ 24°C with B2C sensor) < 40 seconds on 0-10 ppm range < 15 seconds on 0-100 ppm range 1/8" stainless steel tube Sensor type: Voltage requirements: 9.3 – 30 vDC Weight: Panel indicators: PPM, %, RUN, FIN, and COR; ppm or percent oxygen range; fine and coarse span adjustment...

 Open the catalog to page 4

All Teledyne Analytical Instruments catalogs and technical brochures

  1. PEM 9004

    4  Pages

  2. INSTA TRACE

    2  Pages

  3. PHOTO-X

    6  Pages

  4. MODEL MAX5

    2  Pages

  5. 9110T Series

    4  Pages

  6. 9060Z

    4  Pages

  7. 8800 series

    6  Pages

  8. 1220

    4  Pages

  9. SERIES 6700

    6  Pages

  10. model 9070

    2  Pages

  11. MODEL 3010TA

    2  Pages

  12. 3000TA-XL

    2  Pages

  13. BDS series

    4  Pages

  14. 3020T

    2  Pages

  15. 3000TB

    2  Pages

  16. R-15

    1  Page

  17. UFO-130-2

    2  Pages

  18. T-7

    1  Page

  19. R-22MED

    1  Page

  20. R-17MED

    1  Page

  21. PEM-9004

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.