Insta-Trace Micro-fuel Oxygen Sensor
2Pages

{{requestButtons}}

Catalog excerpts

Insta-Trace Micro-fuel Oxygen Sensor - 1

TELEDYNE ANALYTICAL INSTRUMENTS INSTA TRACE Micro-fuel Cell Oxygen Sensor • No waiting • No diverting product • No switching analyzers • No liquid backup eledyne’s patented* innovation called INSTA TRACE ™ eliminates the greatest inconvenience associated with electrochemical oxygen sensors at the trace level - the wait. When a typical electrochemical trace oxygen sensor is removed from its barrier bag for the purpose of replacing an expired sensor, it is exposed to ambient air (209,000 ppm O2). During this transition from an oxygen free environment to open air exposure, the sensor’s electrolyte becomes saturated with dissolved oxygen – and the longer the exposure, the longer the recovery time. The typical recovery period when replacing a sensor is between 6 to 24 hours. The INSTA TRACE Micro-fuel Cell oxygen sensor is capable of measuring below 1 ppm of oxygen within 15 minutes of installation. By reducing the recovery period from several hours to just minutes, users will no longer have to divert unanalyzed product, go to liquid back-up (in the case of the air separation industry), or switch analyzers. The intrinsic value of this innovation has extreme significance in plant operation. Using Teledyne’s Insta Trace technology, meaningful readings below 1 ppm are obtained in only 15 minutes. Without Insta Trace, process downtime can be six hours or more. Built for Reliability and Performance

Open the catalog to page 1
Insta-Trace Micro-fuel Oxygen Sensor - 2

Insta Trace Micro-fuel Cell HOW IT’S DONE WHERE INSTA TRACE CAN BE APPLIED The solution Teledyne engineered to address this recovery concern is simple yet extremely effective. By covering the base of the sensor with a seal, the cell is protected from exposure to ambient air. Insertion in the newly designed cell holder rests the INSTA TRACE sensor against a prong. As the cell holder is closed, the prong punctures the seal thereby allowing the flow of gas to the cathode to begin in a controlled setting. The new cell holder is designed to ensure the prong will not come in contact with the...

Open the catalog to page 2

All Teledyne Analytical Instruments catalogs and technical brochures

  1. PEM 9004

    4 Pages

  2. INSTA TRACE

    2 Pages

  3. PHOTO-X

    6 Pages

  4. MODEL MAX5

    2 Pages

  5. 9110T Series

    4 Pages

  6. 9060Z

    4 Pages

  7. 8800 series

    6 Pages

  8. 1220

    4 Pages

  9. SERIES 6700

    6 Pages

  10. model 9070

    2 Pages

  11. MODEL 3010TA

    2 Pages

  12. 3000TA-XL

    2 Pages

  13. BDS series

    4 Pages

  14. 3020T

    2 Pages

  15. 3000TB

    2 Pages

  16. R-15

    1 Pages

  17. UFO-130-2

    2 Pages

  18. T-7

    1 Pages

  19. R-22MED

    1 Pages

  20. R-17MED

    1 Pages

  21. PEM-9004

    4 Pages

Archived catalogs

  1. 3010TA

    2 Pages