Catalog excerpts
TELEDYNE ANALYTICAL INSTRUMENTS TELEDYNEANALYTICAL INSTRUMENTS >
Open the catalog to page 1The Model 1220 is designed to monitor large industrial plants for flammable gases and vapors to detect and warn of leaks before explosive concentrations of materials can accumulate, providing personnel and equipment safety. In addition, the 1220 can activate a ventilation or sprinkler system or shut down process equipment. The system is composed of a central control station plus remote detectors. The microprocessor- based module is programmable by the user to customize the systems functions, and provides one man calibration capability. It is also easy to add channels for infield upgrades....
Open the catalog to page 4The Series 2000 TCD Analyzers are designed to continuously monitor the concentration, or purity, of a desired gas in a mixture of background gases (i.e., 70-100% H2 in HCs). Thermal conductivity is a property of gases relating to their ability to conduct heat. The detector (TCD) used responds to changes in the component of interest by comparing the sample gas with a reference gas - which is either sealed or flowing. The TCD can be applied in various wetted parts for both corrosive and non-corrosive gas streams. Features include 110 pre- programmed combinations of gases, built-in digital...
Open the catalog to page 5Series 3000M Paramagnetic Oxygen Analyzers offer superior performance for percent oxygen analysis due to the advanced, maintenance free, paramagnetic O2 sensor design. The 3000M provides the operator with long-life, fast response oxygen sensing capability in both inert and corrosive CO2 gas streams. Properly maintained paramagnetic sensors last for years with little or no attention making them ideal for critical measurements.Applications: Challenging petrochemical, steel and cement applications; O2 purity analysis and emissions monitoring > 3000MA Panel mount AӔ - Panel mountBӔ - Wall...
Open the catalog to page 6Low Cost, Highly Flexible Oxygen Analyzer : The 3190 Trace and 3290 Percent O2 Analyzer platforms offer ease-of-use and the essential analyzer requirements in a compact design. The flexibility of this platform allows TAI to mate the 3190 or 3290 controllers with fuel cell, ZrO2 or paramagnetic sensing technologies. The units can be purchased either as stand-alone units or on a high volume OEM, private label basis. Various configurations are available with either AC or DC powered options.If interested in a value-added configuration -- with cal gas selector valve, flow control, and 19 rack or...
Open the catalog to page 7The Series 4000 FID platform is highly flexible. In its most basic configuration - the Model 4020 - Teledyne provides a continuous analysis of the total hydrocarbon (THC) impurities found in bulk gases (N2, H2, O2, He, Ar, CO2) manufactured by the air separation industry.We can also apply this same configuration, in tandem with a sample stripper system, to detect the THC content found in cooling tower water / heat exchanger condensate within a power plant.By placing a packed column upstream of the FID, in conjunction with the added valving and temperature control capabilities, TAI is also...
Open the catalog to page 8The Series 8800 Trace Moisture Analyzers detect moisture from -100 C to ambient dewpoint levels of +20ں C on either a continuous or spot checking basis. The user can select the moisture analysis readout to be displayed as Deg C, Deg F, ppm -- and for natural gas applications -- in lbs of H2O/million cft or g/m3. The moisture sensor employs unique Hyper Thin Film (HTF) technology which offers structural improvements in Al2O3 sensor design. These structural changes provide increased sensitivity, greater stability, and a quicker response time. The 8800 Series can be applied to detect moisture...
Open the catalog to page 95000 Series Near Infrared (NIR) Photometer The Series 5000 NIR Photometer utilizes a chopper stabilized single sample cell, dual wavelength design to continuously monitor water and organic compounds (in the liquid phase) that have distinct absorbance peaks within the NIR region of the light spectrum. In addition to providing inherent stability, this design provides automatic compensation for the background components with an absorbance overlapping that of the component of interest. The Series 5000 is set apart from other commercially available NIR analyzers by its unique sample cell...
Open the catalog to page 106600 Oil in Water Analysis System The 6600 utilizes the ultraviolet absorption principle to detect and continuously measure oil concentration in water with a reproducibility that exceeds standard laboratory techniques. Typical ranges of 0-5 to 0-200 ppm Oil (higher ranges available Ֆ contact factory) Compact, folded optic packaging with approved purged designs for use in hazardous areas Օ Automatic self-cleaning sample cell design suitable for high sample pressure and temperature applications Field-proven, value-added sample system designs available; configuration is based upon intended...
Open the catalog to page 117300 series of Non-Dispersive Infrared (NDIR) gas analyzers > features fast response, high accuracy, sensitivity, stability, and excellent linearity. The analyzers offer cost competitive measurement solutions due in part to the uniquely designed and patented IR detector. The heart of these microprocessor-based units is a temperature compensated, hermetically sealed, steady state thermopile detector integrated into an IR photometric bench. This design eliminates the traditional motor driven chopper wheel, signal conditioning circuitry, and complex optics resulting in a compact and rugged...
Open the catalog to page 12The LGA-3500 is an in-situ, cross stack Tunable Laser Diode Array Spectrometer (TLDAS) capable of detecting a number of compounds, such as O2, CO, CO2, within a combustion process. The LGA- 3500 provides an instantaneous response to process changes, has no moving parts, no cross interference from other gases, and eliminates the need for a costly extractive sample preconditioning system. The rugged design and air purge applied on the optical windows of the laser transmitter and receiver units makes the LGA-3500 easy to maintain and leads to a low cost of ownership. Configurations suitable...
Open the catalog to page 13All Teledyne Analytical Instruments catalogs and technical brochures
-
PEM 9004
4 Pages
-
INSTA TRACE
2 Pages
-
PHOTO-X
6 Pages
-
Model AD300 / MD300
2 Pages
-
MODEL MAX5
2 Pages
-
9110T Series
4 Pages
-
9060Z
4 Pages
-
Model AX300 / MX300
2 Pages
-
8800 series
6 Pages
-
1220
4 Pages
-
Model UltraTrace 3000
4 Pages
-
SERIES 6700
6 Pages
-
Series LXT Smart Transmitter
4 Pages
-
model 9070
2 Pages
-
MODEL 3010TA
2 Pages
-
3000TA-XL
2 Pages
-
UltraTrace 3000
4 Pages
-
BDS series
4 Pages
-
3020T
2 Pages
-
3000TB
2 Pages
-
R-15
1 Pages
-
UFO-130-2
2 Pages
-
T-7
1 Pages
-
R-22MED
1 Pages
-
R-17MED
1 Pages
-
R-15 Oxygen sensor
1 Pages
-
CENELEC Series 3010TAC
4 Pages
-
PEM-9004
4 Pages
Archived catalogs
-
3010TA