Zirconium Oxide Oxygen Analyzers
Open the catalog to page 1Optimizing combustion efficiency and minimizing exhaust emissions are important for proper operation of nearly every industrial process that burns fuel. From clean burning natural gas to dirty coal fired kilns, Teledyne’s Model 9060Z provides reliable and efficient O2 monitoring capabilities by combining field proven zirconium oxide sensor technology with a powerful and versatile microprocessor based controller. Model 9060Z Control Unit The 9060Z O2 analyzer / transmitter provides in-situ analysis capability which can accept signals from up to two zirconia probes for averaging or backup...
Open the catalog to page 29060Z CONTROLLER SPECIFICATIONS: Inputs • One or two zirconia oxygen probes or sensors • One zirconia sensor & auxiliary thermocouple type J, K, R or S • Burner “On” signal (dry contact) • Purge air flow switch Outputs • Four programmable alarm relays • Two isolated 4-20mA or 0-20mA • SSR outputs to purge & calibration check gas solenoid valves • Settable parameters Configurable Output Parameters • Linear oxygen sensor 1 • Linear oxygen sensor 2 • Average oxygen • Very low oxygen • Logarithmic oxygen • Reducing oxygen • Oxygen deficiency • Carbon dioxide • Probe EMF • Auxiliary...
Open the catalog to page 3BBB, TELEDYNE ANALYTICAL INSTRUMENTS Everywhereyoulook' Warranty Instrument is warranted for one year against defects in material or workmanship NOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every product. All specifications and features are subject to change without notice. Teledyne Analytical Instruments (TAI) - Factory 16830 Chestnut Street City of Industry, CA 91748, USA TOLL FREE (888) 789-8168 TEL: 626.934.1500 FAX: 626.934.1651 www.teledyne-ai.com TAI - South...
Open the catalog to page 4All Teledyne Analytical Instruments catalogs and technical brochures
-
PEM 9004
4 Pages
-
INSTA TRACE
2 Pages
-
PHOTO-X
6 Pages
-
Model AD300 / MD300
2 Pages
-
MODEL MAX5
2 Pages
-
9110T Series
4 Pages
-
Model AX300 / MX300
2 Pages
-
8800 series
6 Pages
-
1220
4 Pages
-
Model UltraTrace 3000
4 Pages
-
SERIES 6700
6 Pages
-
Series LXT Smart Transmitter
4 Pages
-
model 9070
2 Pages
-
MODEL 3010TA
2 Pages
-
3000TA-XL
2 Pages
-
UltraTrace 3000
4 Pages
-
BDS series
4 Pages
-
3020T
2 Pages
-
3000TB
2 Pages
-
R-15
1 Pages
-
UFO-130-2
2 Pages
-
T-7
1 Pages
-
R-22MED
1 Pages
-
R-17MED
1 Pages
-
R-15 Oxygen sensor
1 Pages
-
CENELEC Series 3010TAC
4 Pages
-
PEM-9004
4 Pages
Archived catalogs
-
3010TA
2 Pages