3000ZA2G Series Zirconium Oxide Trace / Percent Oxygen Analyzer
1 /3Pages

3000ZA2G Series Zirconium Oxide Trace / Percent Oxygen Analyzer

3000ZA2G Series Zirconium Oxide Trace / Percent Oxygen Analyzer
1 /3Pages

Catalog excerpts

3000ZA2G Series Zirconium Oxide Trace / Percent Oxygen Analyzer-1

3000ZA2G Series Trace / Percent Oxygen Analyzer Zirconium Oxide Technology FEATURES: • Single-sensor design provides complete analysis range from 0-10 ppm to 0-25% • -XL configuration provides ranging down to 0-1 ppm • Fast response time from percent to trace ranges • 3-5 year expected sensor life • Maintenance-free • Front-accessible flow control and monitoring devices • 5-digit LED display and luminescent 2x20 vacuum fluorescent display to show menu functions and parameters • 3U 19” rack form factor minimizes rack space requirement

 Open the catalog to page 1
3000ZA2G Series Zirconium Oxide Trace / Percent Oxygen Analyzer-2

MODEL 3000ZA2G - Trace / Percent Zirconium Oxide Analyzer The 3000ZA2G combines the reliability, flexibility and ease of use of the 3000 platform with the dynamic functionality of zirconium oxide (ZrO2) sensing technology to offer a perfect solution for universal oxygen monitoring in inert gas applications. Zirconium oxide is a non-consuming, solid state sensor. Under a high temperature of 1070°F (575°C), the difference in oxygen partial pressure between the measuring and reference surfaces will create a millivolt differential logarithmically proportional to the difference in PO2. An instrument...

 Open the catalog to page 2
3000ZA2G Series Zirconium Oxide Trace / Percent Oxygen Analyzer-3

MODEL 3000ZA2G - Trace / Percent Zirconium Oxide Analyzer SPECIFICATIONS: Type RANGE ACCURACY REPEATABILITY 3 user-settable ranges, 0-10 ppm to 0-25% ±2% of the active range at constant temperature ±1% of the active range at constant temperature 3 user-settable ranges, 0-1 ppm to 0-25% ±2% of the active range at constant temperature ±1% of the active range at constant temperature 100 seconds on 0-1 ppm range 30 seconds on 0-10 ppm range 30 seconds on 0-10 ppm range 15 seconds for higher trace and percent ranges 15 seconds for higher trace and percent ranges SAMPLE FLOW Instrument air, 0.2 – 0.4...

 Open the catalog to page 3

All Teledyne Analytical Instruments catalogs and technical brochures

  1. PEM 9004

    4  Pages

  2. INSTA TRACE

    2  Pages

  3. PHOTO-X

    6  Pages

  4. MODEL MAX5

    2  Pages

  5. 9110T Series

    4  Pages

  6. 9060Z

    4  Pages

  7. 8800 series

    6  Pages

  8. 1220

    4  Pages

  9. SERIES 6700

    6  Pages

  10. model 9070

    2  Pages

  11. MODEL 3010TA

    2  Pages

  12. 3000TA-XL

    2  Pages

  13. BDS series

    4  Pages

  14. 3020T

    2  Pages

  15. 3000TB

    2  Pages

  16. R-15

    1  Page

  17. UFO-130-2

    2  Pages

  18. T-7

    1  Page

  19. R-22MED

    1  Page

  20. R-17MED

    1  Page

  21. PEM-9004

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.