4 Series B MSOMixed Signal Oscilloscope DatasheetKey performance specifications The 4 Series B MSO sets a new standard for performance, analysis capabilities and overall user experience in bench oscilloscopes -- ideal for debugging and validating embedded systems and power converters. The second generation of this instrument incorporates a new processing platform, more than doubling its responsiveness, and significantly accelerating measurements and data transfers with full support for remote operation and control. Models are available with 4 or 6 FlexChannel® inputs for high visibility into designs. High-resolution 12-bit sampling delivers precise measurements on a new higher-contrast 13.3-inch HD display. And synchronized, multi-channel spectrum analysis facilitates noise hunting and RF measurements. This exceptional measurement performance is paired with an intuitive award-winning user interface making it easy to achieve fast, accurate results. Input channels • 4 or 6 FlexChannel® inputs • Each FlexChannel provides: Record length (all analog / digital channels) • 31.25 Mpoints standard (62.5 Mpoints optional upgrade) Waveform capture rate • >500,000 waveforms/s Standard trigger types • Edge, Pulse Width, Runt, Timeout, Window, Logic, Setup & Hold, Rise/Fall Time, Parallel Bus, Sequence, Visual Trigger, Video (optional), RF vs. Time (optional) • Auxiliary Trigger <300 VRMS (Edge Trigger only) Standard analysis • Cursors: Waveform, V Bars, H Bars, V&H Bars • Spectrum View: Frequency-domain analysis with independent controls for frequency and time domains • FastFrame™: Segmented memory acquisition mode with maximum trigger rate >5,000,000 waveforms per second • Plots: Time Trend, Histogram, and Spectrum • Math: Basic waveform arithmetic, FFT, and advanced equation editor • Search: Search on any trigger criteria Optional analysis • Advanced Spectrum View • RF vs. Time traces, triggers, Spectrograms, and IQ capture • Mask/Limit Testing • Advanced Power Measurements and Analysis • Three-Phase Electrical Analysis (6 channel model only) • One analog signal that can be displayed as a waveform view, a spectrum view, or both simultaneously • Eight digital logic inputs with TLP058 logic probe Bandwidth (all analog channels) • 200 MHz, 350 MHz, 500 MHz, 1 GHz, 1.5 GHz (upgradable) Sample rate (all analog / digital channels) • Real-time: 6.25 GS/s Optional protocol trigger, decode, and analysis I2C, SPI, eSPI, I3C, RS-232/422/485/UART, SPMI, SMBus, CAN, CAN FD, CAN XL, LIN, FlexRay, SENT, PSI5, CXPI, USB 2.0, eUSB2.0, Ethernet, EtherCAT, Audio, MIL-STD-1553, ARINC 429, Spacewire, NRZ, Manchester, SVID, SDLC, 1-Wire, MDIO, and NFC Arbitrary/Function Generator (optional and upgradable) • 50 MHz waveform generation
Open the catalog to page 1Waveform Types: Arbitrary, Sine, Square, Pulse, Ramp, Triangle, DC Level, Gaussian, Lorentz, Exponential Rise/Fall, Sin(x)/x, Random Noise, Haversine, Cardiac Digital voltmeter (free with product registration) • 4-digit AC RMS, DC, and DC+AC RMS voltage measurements Trigger frequency counter (free with product registration) • 13.3 inch (338 mm) optically-bonded assembly High Definition (1,920 x 1,080) resolution Capacitive (multi-touch) touchscreen USB 2.0 Host, USB 3.1 Host, USB 2.0 Device (6 USB ports total); LAN (10/100/1000 Base-T Ethernet); HDMI; Requires connection to high definition display...
Open the catalog to page 2FlexChannel technology enables the ultimate in flexibility. Each input can be configured as a single analog or eight digital channels based on the type of probe you attach. Previous-generation MSOs required tradeoffs, with digital channels having lower sample rates or shorter record lengths than analog channels. The 4 Series B MSO offers a new level of integration of digital channels. Digital channels share the same high sample rate (up to 6.25 GS/s), and long record length (up to 62.5 M points) as analog channels. The TLP058 provides eight high performance digital inputs. Connect as many TLP058...
Open the catalog to page 3nnnn nnr "nnn'nn'n'n" inn n n nnn n m nnnnnn n n n nnnn nn m in nn nnnn n n nnnnnnnn innn nnn i nnn'n nn n nnnn nn nnirmrinn min nnnn "nnn'nn "irn : n n n i i nnn n n n r Beyond just analog and digital, FlexChannel inputs include Spectrum View. This Tektronix-patented technology enables you to simultaneously view both analog and spectral views of all your analog signals, with independent controls in each domain. The stunning 13.3inch (338 mm) display is the largest display in its class. It is also the highest resolution display, with full HD resolution (1,920 x 1,080), enabling you to see many...
Open the catalog to page 4Stacked display mode enables easy visibility of all waveforms while maintaining maximum ADC resolution on each input for the most accurate measurements. The 4 Series B MSO offers a revolutionary new Stacked display mode. Historically, scopes have overlaid all waveforms in the same graticule, forcing difficult tradeoffs: • To make each waveform visible, you vertically scale and position each waveform so that they don't overlap. Each waveform uses a small percentage of the available ADC range, leading to less accurate measurements. For measurement accuracy, you vertically scale and position each...
Open the catalog to page 5Waveform View Start Time [Address (h) Data (h) Cursors Note Measure! Search Positive Duty Cycle |i': 33.04 %_ Positive Pulse Width Meas 3 Positive Pulse Width Manual, Analyze Sample: 12 bits Single: 1 /I_ Viewing three analog channels, eight digital channels, a decoded serial bus waveform, decoded serial packet results table, four measurements, a measurement histogram, measurements results table with statistics and a search on serial bus events - simultaneously! Exceptionally easy-to-use user interface lets you focus on the task at handThe Settings Bar - key parameters and waveform management...
Open the catalog to page 6Touch interaction finally done right Variable font size Oscilloscopes have included touch screens for years, but the touch interface has been an afterthought. The 4 Series B MSO display includes a capacitive touchscreen and provides the industry's first oscilloscope user interface truly designed for touch. Historically, oscilloscope user interfaces have been designed with fixed font sizes to optimize viewing of waveforms and readouts. This implementation is fine if all users have the same viewing preferences, but they don't. Users spend a significant amount of time staring at screens, and Tektronix...
Open the catalog to page 767 Pages