Specifications:
The document outlines the specifications for the TJ14PE5L-LM (400 VAC) 50 Hz Lighting Towers. The generator set has a standby power of 14 kVA (11 kW) and a prime power of 13 kVA (10 kW). It is equipped with a Perkins 403A-15G1 engine, featuring 3 inline cylinders, a displacement of 1.496 liters, and a naturally aspirated aspiration system. The engine operates at 1500 rpm with a 50 Hz frequency.

Performance and Consumption:
The generator's fuel consumption varies with load: 4.1 lt/h at 110% ESP, 3.7 lt/h at 100% PRP, 2.8 lt/h at 75% PRP, and 2 lt/h at 50% PRP. It has a cooling system with a coolant capacity of 6 liters and a lubrication oil capacity of 6 liters.

Alternator Features:
The alternator is brushless with an Automatic Voltage Regulator (AVR) and has a power factor of 0.8. It features a single bearing, 4 poles, and an insulation class of H-F. The degree of protection is IP 21-23.

Cabin Specifications:
TEKSAN Lightning Tower cabins are designed for mobility and include features such as an embedded exhaust muffler, emergency stop button, and air-suction channels for cooling. They are corrosion-resistant and equipped with auxiliary power sockets and a collapsible tow-bar.

Optional Equipment:
Optional equipment includes fuel tanks, isolated cabins, remote monitoring, and hybrid power solutions. Various lighting options and battery bank capacities are available.

Control Panel Features:
The TJ-509T control unit offers multifunctionality and communication capabilities, including USB, RS-485, Ethernet, and GPRS. It supports remote monitoring and control via Rainbow Scada software.

Standards and Compliance:
The equipment complies with ISO8528, ISO3046, NEMA MG-1.22, IEC 600341, BS 4999-5000, VDE 0530 standards, and is produced under ISO9001, ISO14001, OHSAS18001, TSE, CE standards.
See more

Catalog excerpts

TJ14PE5L-LM-1

TJ14PE5L-LM (400 VAC)50 Hz Lighting Towers Output Power Weight (kg) Fuel Tank (lt) Continuous Power Standby Power Prime Power The maximum power which a generating set is capable of delivering continuously whilst supplying a constant electrical load. Average load can be 100%. The generator must not be overloaded. The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 hrs of operation per year under average of 70% load. Overloading isn't permissible. The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs. [email protected] www.teksan.com

 Open the catalog to page 1
TJ14PE5L-LM-3

TEKSAN Lightning Tower cabins have following standard specifications; ■ Cabin designs which are providing mobility in works performed in open areas and works of which usage areas change and suitable for crane and forklift usage, ■ Exhaust muffler embedded in the cabin, ■ Emergency stop button located on the cabin, ■ Air-suction channels developed to provide homogeneous cooling in the cabin, ■ On-cabin case providing to fill water and anti-freeze to the radiator easily, ■ Painting system reinforced against corrosion and oxidation, ■ Advanced performance in terms of sound emission, ■ Electric components...

 Open the catalog to page 3
TJ14PE5L-LM-4

■ The TJ-509T is a next generation genset control unit combining multifunctionality and wide communication possibilities together with a reliable and low cost design. ■ The unit complies and mostly exceeds world's tightest safety, EMC, vibration and environmental standards for the industrial category. ■ Software features are complete with easy firmware upgrade process through USB port. The Windows based PC software allows monitoring and programming through USB, RS-485, Ethernet and GPRS. ■ The PC and server based Rainbow Scada software allows monitoring and control of an unlimited number of gensets...

 Open the catalog to page 4

All Teksan catalogs and technical brochures

  1. TJ35YM

    4  Pages

  2. TJ35BD

    4  Pages

  3. TJ33PE

    4  Pages

  4. TJ22PE

    4  Pages

  5. TJ20BD

    4  Pages

  6. TJ17BD

    4  Pages

  7. TJ15BD-1

    4  Pages

  8. TJ15PE

    4  Pages

  9. TJ15BD

    4  Pages

  10. TJ22PE5L-LE

    4  Pages

  11. TJ14PE5L-LE

    4  Pages

  12. TJ10PE5L-LM

    4  Pages

  13. TJ10BD

    4  Pages

  14. TJ10PE5L-LE

    4  Pages

  15. TJ10PE

    4  Pages

  16. TJ10ER

    4  Pages

  17. Diesel products

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.