1. Catalogs
  2. Teksan
  3. TJ10PE5L-LM
video corpo

TJ10PE5L-LM

TJ10PE5L-LM

TJ10PE5L-LM

Product catalog summary
Specifications:
The document outlines the specifications for the TJ10PE5L-LM (400 VAC) 50 Hz Lighting Towers. The generator set has a standby power of 10 kVA (8 kW) and a prime power of 9 kVA (7 kW). It is designed for continuous operation with a constant electrical load and should not be overloaded. The generator can handle a variable electrical load with an average of 70% and can be overloaded by 10% for 1 hour every 12 hours.

Engine and Alternator:
The engine is a PERKINS model 403A-11G1 with a 3-cylinder inline configuration, naturally aspirated, and a mechanical governor type. It has a displacement of 1.131 liters, a bore of 77 mm, and a stroke of 81 mm. The alternator features include a power factor of 0.8, single bearing, 4 poles, and an insulation class of H-F. The excitation system is AVR (Automatic Voltage Regulator) and brushless.

General Specifications:
The TEKSAN Lightning Tower cabins are designed for mobility and include features such as an embedded exhaust muffler, emergency stop button, air-suction channels for cooling, and corrosion-resistant painting. Optional equipment includes fuel tanks, isolated cabins, remote monitoring, and hybrid power solutions.

Control Panel Features:
The TJ-509T genset control unit offers multifunctionality and communication capabilities, including USB, RS-485, Ethernet, and GPRS. It supports remote monitoring and control through Rainbow Scada software and complies with international standards like ISO8528 and ISO9001.

Standards and Compliance:
The equipment is produced in compliance with ISO9001, ISO14001, OHSAS18001, TSE, and CE standards. Technical information adheres to ISO8528, ISO3046, NEMA MG-1.22, IEC 600341, BS 4999-5000, and VDE 0530 standards.
See more

Catalog excerpts

TJ10PE5L-LM-1

TJ10PE5L-LM (400 VAC)50 Hz Lighting Towers Output Power Weight (kg) Fuel Tank (lt) Continuous Power Standby Power Prime Power The maximum power which a generating set is capable of delivering continuously whilst supplying a constant electrical load. Average load can be 100%. The generator must not be overloaded. The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200 hrs of operation per year under average of 70% load. Overloading isn't permissible. The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs. [email protected] www.teksan.com

 Open the catalog to page 1
TJ10PE5L-LM-3

TEKSAN Lightning Tower cabins have following standard specifications; ■ Cabin designs which are providing mobility in works performed in open areas and works of which usage areas change and suitable for crane and forklift usage, ■ Exhaust muffler embedded in the cabin, ■ Emergency stop button located on the cabin, ■ Air-suction channels developed to provide homogeneous cooling in the cabin, ■ On-cabin case providing to fill water and anti-freeze to the radiator easily, ■ Painting system reinforced against corrosion and oxidation, ■ Advanced performance in terms of sound emission, ■ Electric components...

 Open the catalog to page 3
TJ10PE5L-LM-4

■ The TJ-509T is a next generation genset control unit combining multifunctionality and wide communication possibilities together with a reliable and low cost design. ■ The unit complies and mostly exceeds world's tightest safety, EMC, vibration and environmental standards for the industrial category. ■ Software features are complete with easy firmware upgrade process through USB port. The Windows based PC software allows monitoring and programming through USB, RS-485, Ethernet and GPRS. ■ The PC and server based Rainbow Scada software allows monitoring and control of an unlimited number of gensets...

 Open the catalog to page 4

All Teksan catalogs and technical brochures

  1. TJ35YM

    4  Pages

  2. TJ35BD

    4  Pages

  3. TJ33PE

    4  Pages

  4. TJ22PE

    4  Pages

  5. TJ20BD

    4  Pages

  6. TJ17BD

    4  Pages

  7. TJ15BD-1

    4  Pages

  8. TJ15PE

    4  Pages

  9. TJ15BD

    4  Pages

  10. TJ22PE5L-LE

    4  Pages

  11. TJ14PE5L-LM

    4  Pages

  12. TJ14PE5L-LE

    4  Pages

  13. TJ10BD

    4  Pages

  14. TJ10PE5L-LE

    4  Pages

  15. TJ10PE

    4  Pages

  16. TJ10ER

    4  Pages

  17. Diesel products

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.