Catalog excerpts
KABLOSUZ YANGIN ALARM SİSTEMLERİ WIRELESS FIRE ALARM SYSTEMS
Open the catalog to page 1WIRELESS FIRE ALARM SYSTEMS Teknim Wireless Fire Alarm Systems with TLPWAN Technology can be used in all places such as museums, historical sites, historical churches and mosques, hotels, factories, which require a fire alarm system and where structural wiring is not possible or cable pollution is not desired. Wireless system basically consists of four main components; Fire alarm control panel, Wireless Coordinator, Wireless Repeater, and wireless end units (Detector, Siren, Button, Input / Output Modules etc.) can be integrated into Teknim Addressable Fire systems and a completely wireless...
Open the catalog to page 2WIRELESS FIRE ALARM SYSTEMS Savings of up to 90% in Cable and Labor Costs!! Monitoring Software Repeater Panel Addressable Detector Addressable Sounder Addressable Detector Wireless Coordinator Wireless Coordinator Wireless Detector Wireless Sounder Addressable Panel 26 Wireless Device Wireless Detector Wireless Sounder Wireless Detector Wireless Sounder External Power Supply 26 Wireless Device Wireless Addressable Fire Alarm System Diagram 26 Wireless Device Conventional Sounder Wireless Detector Wireless Sounder Conventional Sounder Conventional Coordinator External Power Supply...
Open the catalog to page 3WIRELESS FIRE ALARM SYSTEMS ACK MECHANISM ACK (Acknowledgment) is a control message that checks whether the data is sent or not and starts the resend mechanism if it is not. TLPWAN uses a 2-layer ACK structure to guarantee the transmission of data. SIGNAL STRENGTH AND DISTANCE • Up to 2500m communication distance at open space • Up to 2500m communication distance at open space • Significant decreases in the signal power level may occur in places with high mobility such as parking lots, warehouses, factories, workshops, or in difficult structures such as multi-column and beam, thick walls,...
Open the catalog to page 4WIRELESS FIRE ALARM SYSTEMS Wireless Addressable Fire System Diagram Monitoring Software Repeater Panel Addressable Detector Addressable Sounder Addressable Detector Wireless Coordinator Wireless Coordinator Wireless Detector Wireless Sounder Addressable Panel 26 Wireless Device Wireless Detector Wireless Sounder Wireless Detector Wireless Sounder External Power Supply 26 Wireless Device Wireless Conventional Fire System Diagram 26 Wireless Device Conventional Sounder Wireless Detector Wireless Sounder Conventional Sounder Wireless Coordinator External Power Supply Conventional Detector...
Open the catalog to page 5TFP-1211 / TFP-1212 / TFP-1214 Intelligent Addressable Fire Alarm Panels Teknim wireless addressable devices are used with Teknim addressable control panels. Wireless addressable systems, designed according to EN54 standards, allow a completely wireless or hybrid system design with existing Teknim addressable control panels. The functions and settings of all wireless devices can be made on the addressable panel. Technical Specifications Number of Devices Supports Per Loop Total Device Support • EN 54-2 and EN 54-4 Certified 1,2 and 4 Loop Options • Wireless Device Support With TWM-1885...
Open the catalog to page 6Wireless Intelligent Addressable Coordinator Teknim TWM-1885 Addressable Coordinator is an interface that enables wireless devices such as detectors, MCPs, I/O Modules and sounders to be operated with Teknim addressable fire alarm panels. Teknim wireless fire alarm systems provide a flexible solution by completely wireless or hybrid structure as well as allowing existing wired structures to be expanded wirelessly especially where wiring infrastructure is not possible. Technical Specifications Standard Operating Frequency Number of Channel Number of Consecutive Repeater Connections GENERAL...
Open the catalog to page 7Wireless Conventional Coordinator Teknim TWM-3885 Conventional Coordinator is an interface device that enables wireless devices to be operated with conventional fire alarm panels. The Wireless Conventional Coordinator module, which can work in full compatibility with all brand and model conventional fire panels by using the desired end of line resistor, processes the signals it receives from all wireless devices and enables the warning and notification functions in the control panel. Technical Specifications Standard Operating Frequency Number of Consecutive Repeater Connections Total...
Open the catalog to page 8Wireless Repeater TWM-1886 Wireless Repeater allows the wireless network area to be expanded by connecting to the coordinator or another repeater. It is mainly used to increase the communication distance between the wireless coordinator and wireless devices. It is suitable for use with both TWM-1885 Wireless Addressable Coordinator and the TWM-3885 Wireless Conventional Coordinator. Technical Specifications Standard Operating Frequency RF Power GENERAL FEATURES • EN 54-18 and EN 54-25 Certified • Fully Compatible with TWM-1885 and TWM-3885 Coordinators • External Power 18-35 VDC • Easy and...
Open the catalog to page 9Wireless Multi Detector (Smoke and Heat) TWD-1850 Wireless Multi Detector offers excellent wireless solutions with wide coverage and long-term battery life, especially in places where wiring is costly or impossible. The wireless multi detector offers different types of detection options in a single detector. In this way, the confusion caused using detectors with different product codes in projects is prevented, and different types of detection needs are provided with software settings to be made in a single detector. Technical Specifications Standard GENERAL FEATURES • EN54-5, EN54-7 and EN...
Open the catalog to page 10Wireless Manual Call Point TWB-1866 is a wireless manual call point used to create manual warning in case of fire. It communicates completely wirelessly with the control panel. TWB-1866 can operate 4 years with single battery or 8 years with two battery. It supports resettable type of operation and additional protection cover can be implemented to avoid situations that may cause false alarms. Technical Specifications Standard Operating Frequency RF Power GENERAL FEATURES • EN54-11 and EN 54-25 Certified • Approx. 500mt Wireless Coverage (Open Area) • 8 Years Battery Lifetime with Two CR123A...
Open the catalog to page 11All TEKNIM ELEKTRONIK AŞ. catalogs and technical brochures
-
INTRUDER ALARM SYSTEM CATALOGUE
32 Pages
-
CONVENTIONAL FIRE ALARM SYSTEM
20 Pages
-
PRODUCT CATALOG
72 Pages
-
TFS-301
1 Pages
-
VAP-408P
4 Pages
-
VPC-104
1 Pages
-
ATP-570
1 Pages
-
VPC-108G
1 Pages
-
VAP-408M
4 Pages
-
TFP-908
2 Pages
-
TRM-904
1 Pages
-
VAV-210
1 Pages
-
TFD-1530
1 Pages
-
VAS-740F
1 Pages
-
VAS-720RP
1 Pages
-
VPC-116 G
1 Pages
-
ATP-540P
2 Pages
-
VAS-740B
1 Pages
-
VAP-304M
3 Pages
-
VAP-404M
4 Pages
-
VAP-304P SET
3 Pages
-
TFP-804
1 Pages
-
ATP-540N
2 Pages
-
VAP-416
4 Pages
-
TFD-13XX SERIES DATASHEET
2 Pages
-
VAS-740 OUTDOOR SIREN
1 Pages
-
VPL-USB
1 Pages