Catalog excerpts
VAP-3XX SERIES ALARM CONTROL PANELS Zones Ÿ VAP-304: 4 zones on main control panel, expandable to 8 zones with optional zone expansion module or with hardwire zonedoubling. Ÿ VAP-308: 8 zones on main control panel, expandable to 12 zones with optional zone expansion module or to 16 zones with hardwire zone-doubling. Ÿ Using each zone with NC or NO contacts devices with or without EOL resistors. Ÿ Selecting each zone as 12 different type (door, window, home, away, 24 hours, fire, tamper, panic…etc.) Ÿ Adjustable zone response speed. Ÿ Additional features of the zones (Entry/exit zone, follower zone, last-door zone, zone with audio / silent…etc.) Ÿ Arming panel automatically without delay time by determining Entry/Exit zones, when someone exits from last-door. Ÿ Adjusting each zone as special zone in order to transmit alarm message to the central station without alarm siren. (for gas detectors, flood detectors) Ÿ Selectable cross zone and double hit features to avoid from false alarm. Ÿ Walking test for each zone. Ÿ Bypassing each zone manually or automatically. Outputs Ÿ 1 siren output : Negative or positive trigger. Adjusting cut off time between 2 to 255 minutes. Ÿ 1 programmable output : Can be used as siren output. Can be used as arm output. Can be used as selectable trouble output.
Open the catalog to page 1Can be used as smoke dedector power (For automatic resetting). Can be used as being active when there is a motion determined zone. Can be used as being active in assigned time period. Keypad Ÿ 2 keypads can be connected: Each keypad has its own address, they do not effect each other. Connecting LED and LCD keypads to the panel separately or together. Ÿ Producing warning sound (chime) by buzzer, when the specific zones become active or inactive. Ÿ Automatic light activation of the determined zones. (For example; when user opens the door, the keypad automatically illuminates)...
Open the catalog to page 2security technology ■ Ability to deliver voice message on any alarm by voice recording module VAV- 210 or voice message module VAV- 218. Calling a central station with secondary Selecting communicator messages. Events which will be sent to the private phones Sending delayed power failure report. Installer code: Able to command all settings related with installation. Master code: Able to command all settings related with users. (Code, time setting... etc). 5 user codes: Able to command arming/ ■ User authorization can be limited for determined time and operation. Temporary guest code: Has...
Open the catalog to page 3All TEKNIM ELEKTRONIK AŞ. catalogs and technical brochures
-
INTRUDER ALARM SYSTEM CATALOGUE
32 Pages
-
CONVENTIONAL FIRE ALARM SYSTEM
20 Pages
-
WIRELESS FIRE ALARM SYSTEMS
13 Pages
-
PRODUCT CATALOG
72 Pages
-
TFS-301
1 Pages
-
VAP-408P
4 Pages
-
VPC-104
1 Pages
-
ATP-570
1 Pages
-
VPC-108G
1 Pages
-
VAP-408M
4 Pages
-
TFP-908
2 Pages
-
TRM-904
1 Pages
-
VAV-210
1 Pages
-
TFD-1530
1 Pages
-
VAS-740F
1 Pages
-
VAS-720RP
1 Pages
-
VPC-116 G
1 Pages
-
ATP-540P
2 Pages
-
VAS-740B
1 Pages
-
VAP-404M
4 Pages
-
VAP-304P SET
3 Pages
-
TFP-804
1 Pages
-
ATP-540N
2 Pages
-
VAP-416
4 Pages
-
TFD-13XX SERIES DATASHEET
2 Pages
-
VAS-740 OUTDOOR SIREN
1 Pages
-
VPL-USB
1 Pages