Catalog excerpts
O teknim Fire and Security Technology
Open the catalog to page 1Bilgi Elektronik, Registered as “R&D Center By The T.C. Ministry of Industry and Science TEKNİM, Teknim is one of the oldest and well-known brands of Turkey in Fire Alarm and Warning Systems, Intruder Alarm Systems and Power Supplies. Novel technologies entirely developed by wide R&D staff are used in all products. Teknim aims to make the life easy and safe for both consumers and installing technicians with the high-quality products developed and produced for nearly 25 years. This catalog covers TEKNİM’s 2018 Fire Systems product portfol
Open the catalog to page 2TdNET® Network
Open the catalog to page 4TFD-1270 Star Connection Maximum 32 Devices TYPICAL SYSTEM DIAGRAM
Open the catalog to page 5ANALOG ADDRESSABLE FIRE ALARM PANEL 1 LOOP TFP-1211 Series panel is a consumer and technician friendly fire Alarm panel with analog address Designed for Harsh Environments. Each Teknim Panel can flawlessly communicate between detector and end-units at long distanced using FLASHLINK loop communication protocol developed by Teknim engineers. It also enables networking up to 16 panels via TdNET protocol and TFC-1208 network module developed genuinely. Thus, it can be operated as a single panel constituted of 16 panels and 7.680 end units. LCD graphic display on TFP-1211 Panels enables easy and...
Open the catalog to page 6GENERAL SPECIFICATIONS - EN 54-2 AND EN 54-4 Certification - Ensures system security for installer companies and end-users via activation procedures required for initial installation. - Technician and user friendly; easy installation, programming and operation specifications - 1 Loop capacity, (Extension to 2 Loops via TFC-1201 Loop Board) - Cable distance up to 2,5 Km per loop - 240 device addressing capacity on each loop - 72 zones that can be individually programmed - Capacity up to total of 7.680 addressed devices and 1.152 zones by network structure (Using optional TFC-1208 Network...
Open the catalog to page 7Standart Ethernet (TCP/IP) Multi-Language Support Display TFP-1211 ANALOG ADDRESSABLE FIRE ALARM PANEL 1 LOOP Technical Specifications Environment EN54-2/4 Yes Yes (English/Turkish) 240/64 graphic screen From the panel and Programming via Teknim Configuration Software Loop Information Loops “J-Y(St)Y...Lg 1000 mt 0,8mm cross section (@250 mA) 2000 mt 0,8mm cross section Cable Type (@75 mA) 2000 mt and Length 1,5mm2 cross section Network TdNET Protocol Yes Maxsimum Panel 16 (with optional TFC-1208 Network Module Humidity Protection Class Power Operating Voltage Operating Frequency Power Fuse...
Open the catalog to page 8ANALOG ADDRESSABLE FIRE ALARM PANEL 2 LOOP TFP-1212 Series panel is a consumer and technician friendly fire Alarm panel with analog address designed for Harsh Environments. Each Teknim Panel can flawlessly communicate between detector and end-units at long distanced using FLASHLINK loop communication protocol developed by Teknim engineers. It also enables networking up to 16 panels via TdNET protocol and TFC-1208 network module developed genuinely. Thus, it can be operated as a single panel constituted of 16 panels and 7.680 end units. LCD graphic display on TFP-1212 Panels enables easy and...
Open the catalog to page 9GENERAL SPECIFICATIONS - EN 54-2 AND EN 54-4 Certification - Ensures system security for installer companies and end-users via activation procedures required for initial installation. - Technical personnel friendly easy installation and programming specifications - 2 Loops capacity - Cable distance up to 2,5 Km per loop - 240 device addressing capacity on each loop, total of 480 device addressing capacity - 72 zones that can be individually programmed - Capacity up to total of 7.680 addressed devices and 1.152 zones by network structure (Using optional TFC-1208 Network module) - Easy to...
Open the catalog to page 10TFP-1212 ANALOG ADDRESSABLE FIRE ALARM PANEL 2 LOOP Technical Specifications Multi-Language Support Yes (English/Turkish) Display 240/64 grafic screen From the panel and Programming via Teknim Configuration Software Loop information Environment Operating Temperature Humidity Protection Class Power Operating Voltage Operating Frequency Power Fuse per Loop Number of Zones 72 “J-Y(St)Y...Lg 1000 mt 0,8mm cross section (@250 mA) 2000 mt Cable Type 0,8mm cross section 2 cross section (@250 mA) 2500 mt 2mm2 cross section (@250 mA)" Maximum Panel 16 (with optional Dimensions (mm) 385 x 380 x 130...
Open the catalog to page 11ANALOG ADDRESSABLE FIRE ALARM PANEL 1 LOOP, NETWORKABLE, 72 ZONE INDICATORS TFP-1221 Series panel is a consumer and technician friendly fire detection panel with analog address designed for Harsh Environments. Each Teknim Panel can flawlessly communicate between detector and end-units at long distanced using FLASHLINK loop communication protocol developed by Teknim engineers. It also enables networking up to 16 panels via TdNET protocol and TFC-1208 network module developed genuinely. Thus, it can be operated as a single panel constituted of 16 panels and 7.680 end units. LCD graphic...
Open the catalog to page 12GENERAL SPECIFICATIONS - Conforms to EN 54-2 and EN 54-4 standards - Ensures system security for installer companies and end-users via activation procedures required for initial installation. - Technical personnel friendly easy installation and programming specifications - 1 Loop capacity, (Extension to 2 Loops via TFC-1201 Loop Board) - Cable distance up to 2,5 Km per loop - 240 device addressing capacity on each loop - 72 zones that can be individually programmed - Capacity up to total of 7.680 addressed devices and 1.152 zones by network structure (Using optional TFC-1208 Network module)...
Open the catalog to page 13TFP-1221 ANALOG ADDRESSABLE FIRE ALARM PANEL 1 LOOP, NETWORKABLE, 72 ZONE INDICATORS Technical Specifications Loop Information Standard Ethernet (TCP/IP) Multi-Language Support Display Programming Loops Maximum Loop Number of Devices per Loop Number of Zones Loop Voltage Cable Type and Length EN54-2/4 Conformity Yes Yes (English / Turkish) 240/64 graphic screen From the panel and via Teknim Configuration Software 1 2 (Extension to 2 Loops via TFC-1201 Loop Board) 240 72 32V ‘'J-Y(St)Y...Lg 1000 mt 0,8mm cross section (@250 mA) 2000 mt 0,8mm cross section (@75 mA) 2000 mt 1,5mm2 cross...
Open the catalog to page 14All TEKNIM ELEKTRONIK AŞ. catalogs and technical brochures
-
INTRUDER ALARM SYSTEM CATALOGUE
32 Pages
-
CONVENTIONAL FIRE ALARM SYSTEM
20 Pages
-
WIRELESS FIRE ALARM SYSTEMS
13 Pages
-
TFS-301
1 Pages
-
VAP-408P
4 Pages
-
VPC-104
1 Pages
-
ATP-570
1 Pages
-
VPC-108G
1 Pages
-
VAP-408M
4 Pages
-
TFP-908
2 Pages
-
TRM-904
1 Pages
-
VAV-210
1 Pages
-
TFD-1530
1 Pages
-
VAS-740F
1 Pages
-
VAS-720RP
1 Pages
-
VPC-116 G
1 Pages
-
ATP-540P
2 Pages
-
VAS-740B
1 Pages
-
VAP-304M
3 Pages
-
VAP-404M
4 Pages
-
VAP-304P SET
3 Pages
-
TFP-804
1 Pages
-
ATP-540N
2 Pages
-
VAP-416
4 Pages
-
TFD-13XX SERIES DATASHEET
2 Pages
-
VAS-740 OUTDOOR SIREN
1 Pages
-
VPL-USB
1 Pages