CONVENTIONAL FIRE ALARM SYSTEM - 2

4 Zone Conventional Fire Alarm Panel TFP-404 supports 4 zones and maximum 32 Conventional detectors and manual call points. It is the first choice of professionals with its solid metal body design, easy installation, and high performance. GENERAL FEATURES • EN 54-2 and EN 54-4 Certified • Fully Monitorable 4 Zone Capacity • Maximum 32 Conventional Detectors for Each Zone • User-friendly, Easy to Manage Indicator Panel • Separate Fire and Error LEDs for Each Zone • Smart Battery Charging Feature Extending Battery Life • Smart Start Feature that Prevents Direct Starting from the Battery •...

Open the catalog to page 2
CONVENTIONAL FIRE ALARM SYSTEM - 3

4 Zone Conventional Fire Alarm Panel General Specifications Standard Maximum Numbers of Detectors EOL Operating Voltage Operating Frequency Power Fuse Backup Battery Imin Number of Monitored Sounder Outputs Sounder EOL General Error Relay Fire Relay AUX Dimensions (mm) Body material and color Weight Operating Temperature Humidity Protection Class

Open the catalog to page 3
CONVENTIONAL FIRE ALARM SYSTEM - 4

8 Zone Conventional Fire Alarm Panel TFP-408 has 8 zones and maximum 32 Conventional fire detectors and manual call points can be connected to each zone. It is the first choice of professionals with its elegant metal body design, easy installation and high performance. The panel meets all technical values required under European Standards. GENERAL FEATURES • Maximum 32 Conventional Detectors for Each Zone • User-friendly, Easy to Manage Indicator Panel • Separate Fire and Error LEDs for Each Zone • Smart Battery Charging Feature Extending Battery Life • Smart Start Feature that Prevents...

Open the catalog to page 4
CONVENTIONAL FIRE ALARM SYSTEM - 5

8 Zone Conventional Fire Alarm Panel General Specifications Standard Maximum Numbers of Detectors EOL Operating Voltage Operating Frequency Power Fuse Backup Battery Imin Number of Monitored Sounder Outputs Sounder EOL General Error Relay Fire Relay AUX Dimensions (mm) Body material and color Weight Operating Temperature Humidity Protection Class

Open the catalog to page 5
CONVENTIONAL FIRE ALARM SYSTEM - 6

Conventional Optical Smoke Detector TFD-3230 Conventional Optical Smoke Detector designed to provide maximum level of protection for small and medium sized places with its advanced optical sensing technology. Detector has a series of algorithms developed to minimize faulty detections and to provide pollution warning. Smoke chamber can be easily removed for cleaning in case of possible pollutions in excessively dusty environments. Technical Specifications GENERAL FEATURES • EN54-7 Certified • Detects Smoke Particles in the Environment via Light Scatter Principle • Supports 2X LED Indicators...

Open the catalog to page 6
CONVENTIONAL FIRE ALARM SYSTEM - 7

Conventional Heat Detector TFD-3240 Conventional heat detector uses two NTC for precise measurement of the environment to detect fire. Detector classified as A2S and will report an alarm at 55°C. Technical Specifications GENERAL FEATURES • EN54-5 Certified • Designed with 2 NTCs to Ensure More Accurate and Precise • Temperature Measurement • Classified as A2S • Supports 2x LED Indicators Enables 360° view • Two Different Colors of Indication by LEDs to Individually Display • Error and Alarm Conditions (Blue/Red) • Supports Parallel Indicator Connection Terminals • Aesthetic and Elegant...

Open the catalog to page 7
CONVENTIONAL FIRE ALARM SYSTEM - 8

Conventional Multi Detector (Optical Smoke and Heat) TFD-3250 Conventional Optical Smoke + Heat Detector uses optical and heat sensing technologies. Detector has a series of algorithms developed to minimize faulty detections. Technical Specifications GENERAL FEATURES • EN54-7 and EN54-5 Certified • Detects Smoke Particles in the Environment via Light Scatter Principle • Detector Classified as A2S for Heat Detection • Supports 2x LED Indicators Enables 360° view • Two Different Colors of Indication by LEDs to Individually Display Error and Alarm Conditions (Blue/Red) • Special Software...

Open the catalog to page 8
CONVENTIONAL FIRE ALARM SYSTEM - 9

Conventional Natural Gas Detector TSD-701 is a natural gas detector which can be connected to conventional fire alarm systems (NO) and Intruder alarm systems (NC) or to be used as a stand-alone device with 12-24V external power supply. It is equipped with 85dB on-board buzzer for audio warning, and with red/ yellow/ green colored led indicators for visual warning. TSD-701 natural gas detector is suitable for ceiling and wall installations. Detector also provides a test button on it to perform tests for all visual and audio warnings. GENERAL FEATURES • TSE TS-EN 50194-1 Certified • 85dB...

Open the catalog to page 9
CONVENTIONAL FIRE ALARM SYSTEM - 10

Conventional Remote Indicator In cases where alarm LEDs are not visible due to installation of detectors on high ceilings, false ceilings, raised floor, restricted access rooms etc., this device is used as an additional indicator light. The big red LED in 10mm diameter can be seen even from high ceiling. Technical Specifications Power Alarm Consumption Weight Dimensions (mm) Body Material and Color Operating Temperature Humidity Protection Class

Open the catalog to page 10
CONVENTIONAL FIRE ALARM SYSTEM - 11

Conventional Manual Call Point TFB-3165 is designed to be used with all brands of conventional fire alarm systems and comply with EN54-11. Internal 470-ohm resistance allow ease of installation. It has resettable operation structure which can be reset by using a special plastic key. Suitable for flush and surface mounting. An optional transparent protection cover can be installed to avoid false alarms by accidental pressing. Technical Specifications • EN 54-11 Certified • Resettable • NC/NO Selection • Includes 470 Ohm Resistance, does not Require Additional Connection • Optional...

Open the catalog to page 11
CONVENTIONAL FIRE ALARM SYSTEM - 12

Conventional Emergency Call Points Designed to be connected to any brand of conventional fire detection systems. Internal 470-ohm resistance allow ease of installation. It is suitable for flush and surface mounting. An optional transparent protective cover can be installed. It is easily resettable via special key. Technical Specifications GENERAL FEATURES • Resettable Type • NC/NO Selection • Includes 470 Ohm Resistance, does not Require Additional Connection • Transparent Protection Cover can be Installed. Cover can be Sealed • Suitable for Flush and Surface Mounting • Compatible With all...

Open the catalog to page 12

All TEKNIM ELEKTRONIK AŞ. catalogs and technical brochures

  1. TFS-301

    1 Pages

  2. VAP-408P

    4 Pages

  3. VPC-104

    1 Pages

  4. ATP-570

    1 Pages

  5. VPC-108G

    1 Pages

  6. VAP-408M

    4 Pages

  7. TFP-908

    2 Pages

  8. TRM-904

    1 Pages

  9. VAV-210

    1 Pages

  10. TFD-1530

    1 Pages

  11. VAS-740F

    1 Pages

  12. VAS-720RP

    1 Pages

  13. VPC-116 G

    1 Pages

  14. ATP-540P

    2 Pages

  15. VAS-740B

    1 Pages

  16. VAP-304M

    3 Pages

  17. VAP-404M

    4 Pages

  18. VAP-304P SET

    3 Pages

  19. TFP-804

    1 Pages

  20. ATP-540N

    2 Pages

  21. VAP-416

    4 Pages

  22. VPL-USB

    1 Pages