Electronic sprayer kit P&S-360-MXX NEBxXX IHM MICRONICE TECHNOLOGY P&S-360 Plug&Spray External tank Nebulization kit P&S-360 Thank you for trusting Tekceleo and buying this nebulizer system. Please follow the instructions below before using the Kit Plug&Spray-360-MXX NEBxXX IHM
Open the catalog to page 1P&S-360 Plug&Spray External tank www.tekceleo.fr Phone : +33 (0)4 92 28 05 16 – contact@tekceleo.fr 1047, route des Dolines – Business Pole – 06560 Sophia Antipolis
Open the catalog to page 2Electronic Control Unit Characteristics Characteristics Nebulizers Characteristics Supply voltage Current consumption/ Nebulizer Time response 60 cm Cable length If you need a different cable Any cable length change made by the length, please contact us client will impact the ECU operation Dimensions in mm (LxWxH) Spray head 04 Microns H-360-M04 Spray head 08 Microns H-360-M08 Spray head 12 Microns H-360-M12 and HG-360-M12 Flow rate : 1,2 ml/min +/- 0,2 ml/min Drop diameter : 4 μm +/- 1 μm Flow rate : 2 ml/min +/- 0,3 ml/min Drop diameter : 8 μm +/- 2 μm Flow rate : 3,5 ml/min +/- 0,5...
Open the catalog to page 3Instructions to set up the P&S 360 Instructions: ➢ Fill in the tank with liquid. ➢ Assemble the fluidic system with the H-360 Nebulizer . Please make sure to respect the liquid circulation (see Page 5 and 6). ➢ For the electronic assembly please make sur to plug the 12V adapter to the 12Vin of the IHM P&S MXX at the very end : 1. Connect the IHM P&S MXX to the ECU Pump ( CMD2-CMD2/12Vout-12V) and to the ECU NEBxXX ( BNC-BNC-12Vout-12V) 2. Connect the H-360 Nebulizers to the ECU NEBxXX via the mini XLR connectors 3. Connect the IHM P&S MXX to the power supply (12V adapter-12Vin) and then...
Open the catalog to page 4P&S-360 NEBxXX Fluidic System Assembly Plastic Tube To Nebulizer Plastic Tube To Pump Tank Inox Tube Plastic Tube Inox Tube ( Neb Tank) To Nebulizer Inox Tube 500 cm P&S-360 Plug&Spray External tank www.tekceleo.fr Phone : +33 (0)4 92 28 05 16 – contact@tekceleo.fr 1047, route des Dolines – Business Pole – 06560 Sophia Antipo
Open the catalog to page 5P&S-360 NEBxXX Fluidic System Assembly Check that the tank is at the nebulizer level ( see figure below) . Putting the tank above the nebulizer can create pressure on the membrane and create dripping. 500 cm P&S-360 Plug&Spray External tank www.tekceleo.fr Phone : +33 (0)4 92 28 05 16 – contact@tekceleo.fr 1047, route des Dolines – Business Pole – 06560 Sophia Antipo
Open the catalog to page 6ON/OFF and Flow Rate Control via BNC Connector Without Control Box N.B: The default State of BNC connector is always at 3.3V / the functions below are insured when the 12VDC power supply is connected On/Off + Flow Rate Control (PWM) : ➢ The default State of BNC connector is at 3.3V ➢ By Default without input from BNC : Nebulizer is ON ➢ 100% Duty Cycle : Nebulizer ON ( Frequency : 150 Hz up to 500 Hz) ➢ 0% Duty Cycle : Nebulizer OFF ( Frequency : 150 Hz up to 500 Hz) 150Hz/3.3V PWM signal ➢ From 0% to 100% Duty Cycle : Linear Nebulizer Flow Rate Variation Nebulizer ON/OFF Flow Rate Control...
Open the catalog to page 7PUMP ON/OFF Control N.B: The default State of RCA connector is always at 3.3V / the functions below are insured when the 12VDC power supply is connected On/Off : ➢ The default State of RCA connector is at 3.3V Pump Flow Rate vs Duty Cycle ➢ By Default without input from RCA : Pump is ON ➢ 100% Duty Cycle : Pump ON ( Frequency : 150 Hz up to 500 Hz) ➢ 0% Duty Cycle : Pump OFF ( Frequency : 150 Hz up to 500 Hz) ➢ From 0% to 100% Duty Cycle : Linear Pump Flow Rate Variation ( in order to ensure proper priming , please keep flow rate above 50%) Function Pump ON/OFF Control Any voltage > 3.3V on...
Open the catalog to page 8Electronic Control Unit NEBxXX and Nebulizer Dimensions Step Files available upon request P&S-360 Plug&Spray External tank www.tekceleo.fr Phone : +33 (0)4 92 28 05 16 – contact@tekceleo.fr 1047, route des Dolines – Business Pole – 06560 Sophia Anti
Open the catalog to page 9Tank Dimensions Capacity : 500 ml Step Files available upon request P&S-360 Plug&Spray External tank www.tekceleo.fr Phone : +33 (0)4 92 28 05 16 – contact@tekceleo.fr 1047, route des Dolines – Business Pole – 06560 Sophia Antipo
Open the catalog to page 10Pump Dimensions P&S-360 Plug&Spray External tank www.tekceleo.fr Phone : +33 (0)4 92 28 05 16 – contact@tekceleo.fr 1047, route des Dolines – Business Pole – 06560 Sophia Antipo
Open the catalog to page 11Jack Connector 12VDC Power Supply Electronic Control NEBxXX Nebulizer Output connectors BNC Connector On/Off and Flow Rate Control Electronic Control Unit_TOP GND Electronic Control Unit_BOTTOM P&S-360 Plug&Spray External tank www.tekceleo.fr Phone : +33 (0)4 92 28 05 16 – contact@tekceleo.fr 1047, route des Dolines – Business Pole – 06560 Sophia Antipo
Open the catalog to page 12For more information Please visit ou website P&S-360 Plug&Spray External tank www.tekceleo.fr Phone : +33 (0)4 92 28 05 16 – contact@tekceleo.fr 1047, route des Dolines – Business Pole – 06560 Sophia Antipo