WING-R EC & WING-G EC - DESIGN AIR CURTAIN-1

WING-R EC & WING-G EC DESIGN AIR CURTAIN FOR VERTICAL INSTALLATION

 Open the catalog to page 1
WING-R EC & WING-G EC - DESIGN AIR CURTAIN-2

WING-R EC DESIGN AIR CURTAIN steelcomposite design discharge nozzle patented, steplessly variable high-quality powder coated or with stainless steel housing intake grille with micro grille behind it WING-G EC DESIGN AIR CURTAIN WING-R EC with a curved design and WING-G EC with a straight design are particularly suitable for curved sliding doors, automatic linear sliding doors as well as for retrofitting to revolving doors. The timeless design and user-friendly technology will satisfy architects, planners, clients and operators in equal measure. WING-R EC and WING-G EC are the ideal solution wherever...

 Open the catalog to page 2
WING-R EC & WING-G EC - DESIGN AIR CURTAIN-3

+ Made in Germany + ErP 2015 ready / EC fans + Patented, multi-adjustable Jetflow discharge nozzle with adaptive, asymmetrical nozzle cross-section (large throw distance, low noise, optimum shielding) + Certified by TÜV-Süd + Self-supporting steel/aluminium composite construction. Screws are not visible. + Invisible energy supply + Simple to install + Individual RAL colours available or as stainless steel version + Different heating media possible + Individual unit lengths up to 3000 mm EC fans The efficiency of the EC fans used by TEKADOOR is > 90% under partial load operation. This is 30–35%...

 Open the catalog to page 3
WING-R EC & WING-G EC - DESIGN AIR CURTAIN-4

Heating connections – flow and return – for easy connection to the on-site heating system. Simple electrical connection of the power supply 230 V/50 Hz thanks to the internal connection box. - Connections: Either from below or above, invisible within the door air curtain. Exception: Electrical units with a heating capacity greater than 22.5 kW. Floor mounted vertical unit

 Open the catalog to page 4
WING-R EC & WING-G EC - DESIGN AIR CURTAIN-5

Data cable connection/interface Jetflow discharge nozzle (WING-R) Standard connection options for the data cable and an optional solenoid valve or thermo-electric shut-off valve within the unit. Simple plug and play of the data cable. Jetflow discharge nozzle with adaptive, asymmetrical nozzle cross-section. The special design of this patented discharge nozzle permits stepless variation of the discharge angle combined with a longer guided, smooth air stream with optimum throw distance. Control: Input for the data cable to the control unit. Auxiliary: Output for parallel operation with other units....

 Open the catalog to page 5
WING-R EC & WING-G EC - DESIGN AIR CURTAIN-6

DISCHARGE SIDE ACCESS SIDE Draufsicht Draufsicht Revisionsseite stehend LINKS Ausblasseite Ansaugseite Revisionsseite stehend LINKS Ansaugseite Ansaugseite INTAKE SIDE inspection panel inspection panel Draufsicht inspectionDraufsicht A stehend RECHTS Draufsicht panel stehend RECHTS Draufsicht inspection stehend LINKS panel inspection panel Technische Änderungen vorbehalten * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES Connection-ready door air curtainø 50visible installation as a floor mounted vertical unit, with a curved design. for IN Ambient air intake is fromconnectionon the room side....

 Open the catalog to page 6
WING-R EC & WING-G EC - DESIGN AIR CURTAIN-7

ACCESS SIDE INTAKE SIDE REAR Connection-ready door air curtain for visible installation as a floor mounted vertical unit, with a straight design. Ambient air intake is from the side, on the room side.

 Open the catalog to page 7
WING-R EC & WING-G EC - DESIGN AIR CURTAIN-8

STANDARD CIRCUIT DIAGRAM FOR LPHW interface (optional) Stufe MODE Standard supplied shielded datacable (20 m) 1:1 straight wired RJ 45 connentors! Magnetic valve (OPTIONAL) to input CONTROL next PCB weiss/white gelb/yellow Standard Anschlusskabel (20 m) mit RJ-45 Stecker zum Steuerteil (CONTROL) Adresse 1-9 Magnetventil (OPTIONAL) Mains switch and fuses 3 to be installed by third parties must comply to all applicable ruls and 230V/ 50Hz requirements! Room Termostat Adress Schalter 0 = MASTER 1 - 9 = SLAVE Technical changes reserved * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES GTM 2 EC Nr.:...

 Open the catalog to page 8
WING-R EC & WING-G EC - DESIGN AIR CURTAIN-9

CIRCUIT DIAGRAM ELECT. HEAT EXCHANGER interface (optional) Room thermostat zum Steuerteil (CONTROL) Adresse 1-9 Adress switch 0 = MASTER 1 - 9 = SLAVE Adress Schalter 0 = MASTER 1 - 9 = SLAVE Technical changes reserved Datum 01.08.2014 Maßstab GTM 1 E EC control unit with optional ModBus interface 2 languages (German/English can be selected), menu-prompted electronic standard control for air curtains with energy-saving EC motors and electrical heating. Operation/navigation is performed with a central rotary multi-selector. Menu operation via 2.4" colour display with text and icon display for...

 Open the catalog to page 9
WING-R EC & WING-G EC - DESIGN AIR CURTAIN-10

OPTIONAL ACCESSORIES Thermostatic straight-way valve Door contact solenoid switch Frost protection thermostat (Setting range + 25 °C to + 45 °C) limits the discharge temperature (constant supply air temperature limitation). Also available as a 3-way valve. In automatic mode switches on the door air curtain in the preselected stages – in conjunction with GTM 2 EC, GTM 3 EC and GTM 2 E EC. For monitoring LPHW heat exchangers exposed to the risk of frost. As soon as the temperature falls below +7 °C, the fans are switched off and an optional solenoid valve is opened.

 Open the catalog to page 10
WING-R EC & WING-G EC - DESIGN AIR CURTAIN-11

Room thermostat Thermo-electric shut-off valve Prevents overheating or overcooling of the room/vestibule in automatic operation. Opens or closes the heating water circuit in the summer/winter setting of the control unit, to close the heating water circuit during summer operation or when the air curtain is not working (normally closed). Caution: If solenoid valves or thermoelectric shut-off valves are used, it is expressly recommended to install a frost protection thermostat (automatically actuated) and a strainer. 230 V / 50 Hz, normally closed. On-site installation in the heating flow. Actuation...

 Open the catalog to page 11
WING-R EC & WING-G EC - DESIGN AIR CURTAIN-12

WING-R/G EC TECHNICAL DATA

 Open the catalog to page 12
WING-R EC & WING-G EC - DESIGN AIR CURTAIN-13

TECHNICAL DATA Design based on: recommended operating point intake temperature tLE = +20 °C discharge temperature tLA = +34 °C throw distance = up to 2.50 m * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES 1. Rated operation based on operating point (see above), discharge temperature control recommended. 2. Measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions. A well-balanced pressure ratio is one of the prerequisites for perfect function.

 Open the catalog to page 13