DUAL EC - THE ENERGY SAVER
16Pages

{{requestButtons}}

Catalog excerpts

DUAL EC - THE ENERGY SAVER - 1

i - 14 + r • ■ r. « k 4 k ■ > > k r '• * m . > ■ » % i a. -a a, a. n * a. a. m a, > I a a. a a a. e.* ii *n ’ " ■ • * ■ a ■ t r'lkf'Mikf ii tint ■ till lllliim *#f * + * ***■!■ *••■■■■■,■ !■■•• i I . ailttl • * ■ ■ t i ■ Min w * iM'iiiitniitmimii ■■■*■■ DUAL ECTHE ENERGY SAVER INDIVIDUAL INNOVATIVE ENERGY-SAVING fffi

Open the catalog to page 1
DUAL EC - THE ENERGY SAVER - 2

sheet steel housing intake grille with micro-intake grille behind it high-quality powder coated discharge fins each adjustable in 5 stages + Inspection with hidden screws Special design Heating media Dual EC is the energy-saving model for applications in shops and retail. Wherever there is only a limited supply of heating energy available which must be used efficiently, the Dual EC has a special way of fulfilling all the requirements on a modern door air curtain unit. Installation-ready model available in 3 installation variants. Free-hanging, installed flush with the ceiling as a cassette...

Open the catalog to page 2
DUAL EC - THE ENERGY SAVER - 3

+ Made in Germany + ErP 2015 ready / EC fans + Reduced heating costs thanks to dual technology + Certified by TUV-Sud + Robust, self-supporting sheet steel housing + High-quality powder coating + Individual colours available (standard RAL 9016) + 3 installation types + Individual unit lengths up to 2500 mm + Easy-maintenance filter cleaning thanks to micro grille + Aerodynamically optimised double discharge fins + Different heating media possible EC fans The efficiency of the EC fans used by TEKADOOR is > 90% under partial load operation. This is 30-35% higher than for conventional AC fans....

Open the catalog to page 3
DUAL EC - THE ENERGY SAVER - 4

Connection box (LPHW) Simple electrical connection via connection box (voltage supply 230V/50Hz on the top of the unit); connection can optionally also be located at the side.

Open the catalog to page 4
DUAL EC - THE ENERGY SAVER - 5

Data cable connection/interface Simple, standard plug and play connection of the data cable and an optional solenoid valve on the top side of the unit. The connection can be offset on request. Control: Input for the data cable to the control unit. Auxiliary: Output for parallel operation with other units, Double discharge fin The shielding performance of the door air curtain unit is optimised by adjusting the discharge fins. The fins can be adjusted in 5 stages. During the heating period, the discharge fins should be tilted outwards by 10 to 15 degrees to prevent cold air coming in from the...

Open the catalog to page 5
DUAL EC - THE ENERGY SAVER - 6

DUAL EC INSTALLATION VARIANTS

Open the catalog to page 6
DUAL EC - THE ENERGY SAVER - 7

A = VARIABLE UNIT LENGTH WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES Connection-ready free-hanging door air curtain unit for visible installation directly above the door. Ambient air intake is at the front, on the room side.

Open the catalog to page 7
DUAL EC - THE ENERGY SAVER - 8

Cassette hidden inspection panel screws BOTTOM VIEW SIDE VIEW Electrical and water connections at the side FRONT VIEW Pre-perforated for intake from the suspended ceiling Intake filter with micro-filter Fixation only for units longer than 2 m M8 rivet nuts A = VARIABLE UNIT LENGTH * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES Connection-ready door air curtain unit with intake on the underside and surrounding frame for installation flush with the ceiling. Ambient air intake is from the underside, on the room side. Freely accessible inspection panel on the underside of the unit.

Open the catalog to page 8
DUAL EC - THE ENERGY SAVER - 9

Suspended ceiling unit 260 BOTTOM VIEW SIDE VIEW FRONT VIEW FRONT VIEW Platine Circuit board Print CONTROL AUXILIAR 70 75 115 A = VARIABLE UNIT LENGTH * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES Connection-ready door air curtain unit with intake chamber on the underside and intake and discharge sliding supports for installation in a suspended ceiling. Only the intake and discharge grilles are visible from below. Ambient air intake is from the underside, on the room side. CAUTION: The inspection panel is on the underside of the unit. Therefore, it is essential that the suspended ceiling...

Open the catalog to page 9
DUAL EC - THE ENERGY SAVER - 10

OPTIONAL ACCESSORIES Thermostatic straightway valve Door contact solenoid switch (Setting range + 25 °C to + 45 °C) limits the discharge temperature (constant supply air temperature limitation). Also available as a 3-way valve. For problem-free, vibration-free ceiling attachment, consisting of M8 threaded rods, up to 1000 mm length, vibration dampers, turn-buckles and counter nuts. In automatic mode switches on the door air curtain in the preselected stages.

Open the catalog to page 10
DUAL EC - THE ENERGY SAVER - 11

Frost protection Solenoid valve thermostat Room thermostat Thermo-electric shut-off valve For monitoring LPHW heat exchangers exposed to the risk of frost. As soon as the temperature falls below +7 °C the fans are switched off and an optional solenoid valve is opened. Opens or closes the heating water circuit in the summer/ winter setting of the control unit, to close the heating water circuit during summer operation or when the air curtain is not working (normally closed). Caution: If solenoid valves or thermo-electric shut-off valves are used, it is expressly recommended to install...

Open the catalog to page 11
DUAL EC - THE ENERGY SAVER - 12

DUAL EC M TECHNICAL DATA FREE HANGING / CASSETTE SUSPENDED CEILING Design based on: recommended operating point Intake temperature tLE = +20 °C Discharge temperature tLA = +34 °C Discharge height = up to 2.70 m * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES 1. Rated operation based on operating point (see above), discharge temperature control recommended. 2. Measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions. 3. For the Dual Z (suspended ceiling version), this dimension changes to 390-490 mm. 4. For the Dual Z this dimension changes...

Open the catalog to page 12
DUAL EC - THE ENERGY SAVER - 13

DUAL EC L TECHNICAL DATA FREE HANGING / CASSETTE SUSPENDED CEILING Design based on: recommended operating point Intake temperature tLE = +20 °C Discharge temperature tLA = +34 °C Discharge height = up to 3.00 m * WE RESERVE THE RIGHT TO MAKE TECHNICAL CHANGES 1. Rated operation based on operating point (see above), discharge temperature control recommended. 2. Measured at a lateral distance of 3 m. Sound pressure level may very depending on surrounding conditions. 3. For the Dual Z (suspended ceiling version), this dimension changes to 390-490 mm. 4. For the Dual Z this dimension changes...

Open the catalog to page 13