Catalog excerpts
TEDDINGTON APPLIANCE CONTROLS LTD l Non-Electric Safety Valve l Manual Reset l Manual On/Off for Appliance Servicing l Sensor System Fails Safe if Broken l Two Alternative Temperature Settings l Remote Sensing Up To 20m (66ft) l Conforms To BS 5410 Part 1 l Approved To OFS E101 Application The KBB is designed as a fire safety shut-off valve for use on oil burning equipment. The valve is to be installed in the oil supply pipeline outside the building with the sensor mounted firmly inside the appliance above the burner. The capillary should then be run in a protected position without over-sharp bends particularly near the sensor and valve. The outline detail overleaf illustrates the relative positions of the valve and the sensor in a boiler compartment. Operation The KBB is a quick acting thermally operated valve with a spring loaded trip mechanism and sealed temperaturesensing system consisting of a bellows, capillary tube and sensor phial. The valve will snap closed when the temperature at the sensor phial exceeds the set value. The valve will remain in the shut-off condition until the appropriate action has been taken to restore normal operating conditions and the reset button has been pressed. Physical Description The KBB is a compact valve of corrosion resistant, noncombustible construction and entirely mechanical in operation, requiring no power supply. The sensor is connected to the valve by a capillary, which cannot be detached. The reset button can be found at the base of the valve head and is pressed to reset the valve or if pulled will toggle the valve into the shut-off condition. The operation of the fire valve can be verified by using the KBT1000 test unit set to the appropriate temperature. This checks that the operation to shut-off the oil supply pipe takes place and enables a check to be made that the valve can be manually reset once the sensor phial temperature has reduced to normal operating level. The reset button must be pressed firmly to ensure the valve is positively latched in the open position. The valve can also be shut-off manually by pulling the reset button.
Open the catalog to page 1TEDDINGTON APPLIANCE CONTROLS LTD Technical Specification Nominal Shut-down Temperatures Materials Valve body and head Oil supply pipe at atmospheric pressure Sensor phial and capillary Valve seal Nitrile Elastomer Oil supply pipe at maximum pressure (10psi) Oil Supply Pipe Connections 1/4” BSP internal taper thread. Spanner flats at connections 19mm (3/4”) Weight (approx.) Capillary Tube With 1.5m capillary OFTEC Certificate Numbers Nominal Fuel Flow Rate Kerosene 56 litres/hour at 1 meter head 85 litres/hour at 2 meters head 50 litres/hour at 1 meter head Valve Seat 6.4mm (1/4”) diameter...
Open the catalog to page 2All Teddington Controls catalogs and technical brochures
-
QW
4 Pages
-
DCA/B
1 Pages
-
38000
2 Pages
-
GM
3 Pages
-
DSO
2 Pages
-
DSS
2 Pages
-
DCA/A
2 Pages
-
LTSA
2 Pages
-
LTATESA
2 Pages
-
SOV
2 Pages
-
52000
2 Pages
-
51000
2 Pages
-
MSV
2 Pages
-
ATESA 203L
2 Pages
-
COMSA
2 Pages
-
TESA
2 Pages
-
GBR
2 Pages
-
FrostSentry
2 Pages
-
CombiSave
2 Pages
-
DST
2 Pages
-
54000
2 Pages
-
FFD
2 Pages
-
TESA 2394
2 Pages
-
CSV
2 Pages
-
ATESA 105
2 Pages
-
53000
2 Pages
-
51000 Solenoid Valve
2 Pages
-
Oil Filter and Valve
1 Pages
-
KBB Adaptors
1 Pages
-
43000 Series Flow Switches
2 Pages