FrostSentry - 1

TEDDINGTON GROUP l Condensate Pipes from freezing Prevents - Compact l Trace Heater - Straight l forward to install - Auto-sensing, automatic activation when l temperature drops below 2.5° C - Isolated l low voltage output - Works lwith any make of condensing boiler - 'Active' l and 'Standby' Indicator LED's - Patent lApplied for: GB1014462.4 Application The Frost Sentry is designed to prevent Condensate Pipes from Freezing when temperatures fall below 2.5° C. This compact unit consumes less than 10W in standby and 30W when at maximum heating. Once installed, the Frost Sentry will constantly monitor the external temperature. If it falls below 2.5° C, the Frost Sentry will activate and gently warm the inside of the Condensate pipe. The further the temperature drops, the warmer the temperature in the pipe. Once fitted, this unit will ensure that the Condensate Pipes from your Boiler or Air Conditioning unit will not freeze, even down to -20° C. Physical Description It is supplied with all parts required to finish*. This unit is compact and robust. Housed in a strong, flame retardant white ABS box with a smoked transparent lid which allows both the Standby LED and Active LED to show through. The Frost Sentry comes with 3 metres of Heater Cable, 3 metres of Temperature Probe and 2.75 metres of Clear Plastic PVC tubing. These can be shortened to a minimum of 1m metre. The Frost Sentry is truly a fit and forget device that will ensure that no-matter how far the temperature falls, to a minimum of -20° C. The boiler will continue to function in the harshest conditions. It is supplied with: 1. 2.75m Clear PVC tubing 2. 3m Coaxial Trace Heating cable - 3 pin connector 3. 1m Twin Core Electrical Cable + Connector Block 4. 3m Temperature Probe – 2 pin connector 5. Power Supply Cable 6. Rubber bung 7. T Piece 8. Pipe adaptor * Does not include condensate pipe.

Open the catalog to page 1
FrostSentry - 2

TEDDINGTON GROUP Technical Specification Physical Properties Electrical Rating Supply Rating - Running - Standby Mass (Incl Lead and Plug) Mains Lead Trace Heater Cable Twin Core Extn Cable and Connector Output Rating Ambient Temp IP Rating Outline Details 230Va.c. Supply Connection Frost Sentry Control Unit Bright Ideas Since 1928 Model: THS-FS-01 Part of the Teddington Home Sentry Range www.tedcon.com FROST SENTRY Teddington Group Mains Supply Patent applied for: GB1001999.0 Warranty void if opened No serviceable parts within Teddington Group St Austell, PL25 3HG (T ) 01726 222 505 (E)...

Open the catalog to page 2

All Teddington Controls catalogs and technical brochures

  1. QW

    4 Pages

  2. DCA/B

    1 Pages

  3. 38000

    2 Pages

  4. GM

    3 Pages

  5. DSO

    2 Pages

  6. DSS

    2 Pages

  7. DCA/A

    2 Pages

  8. LTSA

    2 Pages

  9. LTATESA

    2 Pages

  10. SOV

    2 Pages

  11. 52000

    2 Pages

  12. 51000

    2 Pages

  13. MSV

    2 Pages

  14. ATESA 203L

    2 Pages

  15. COMSA

    2 Pages

  16. TESA

    2 Pages

  17. GBR

    2 Pages

  18. CombiSave

    2 Pages

  19. DST

    2 Pages

  20. 54000

    2 Pages

  21. FFD

    2 Pages

  22. KBB

    2 Pages

  23. TESA 2394

    2 Pages

  24. CSV

    2 Pages

  25. ATESA 105

    2 Pages

  26. 53000

    2 Pages

  27. KBB Adaptors

    1 Pages