FFD
2Pages

{{requestButtons}}

Catalog excerpts

FFD - 1

TEDDINGTON APPLIANCE CONTROLS LTD FFD GAS FLAME SAFETY DEVICE ? High Gas Flow Capacity. ? Available with Integral Solenoids for Automatic Gas Appliances. ? for Natural Gas and LPG. Suitable ? by British Gas to:EN. 161: 1991. Certified ? Non Mercury Charges used for Variants for New Appliances as Required by British Gas. Application Flame safety devices are a necessary safety requirement for gas burners on most domestic gas appliances including cookers, gas fires, gas boilers etc. Teddington FFD's meet the latest market demand for a non-toxic charge as alternative to mercury filled systems. Flame heat is detected by a small sensor connected by capillary tube to the control valve, which is held open while the burner is alight. Physical Description Models can be provided with particular features to suit The FFD body is constructed of aluminium or aluminium special customer requirements and this includes a version with a manual over-ride to the solenoid function. and brass, depending on type, and is connected to the sensor by a copper or stainless steel capillary. Special clips and phial ferrules are available to support sensors correctly in relation to gas burners. The solenoid has a steel cover with 3 flying leads including earth wire with termination and length to customers' requirements. FFD's are available with inlet and outlet to suit virtually all-standard appliances but preferred connections are illustrated overleaf. Capillary: normal lengths 350mm

Open the catalog to page 1
FFD - 2

TEDDINGTON APPLIANCE CONTROLS LTD Technical Specification Valve Nominal Full Flow Rate Weight (approx) Standard model 100g Solenoid model 200g at pressure drop of 1mbar Maximum Working Pressure Ordering Information The following information must be given when ordering……. 45 mbar Maximum Sensor Temperature Specifiy details of: GAS operated 850°C ? Model code. ALTERNATIVE CHARGE 450°C On most cookers this temperature can be achieved with little or no alteration to the sensor support. ? Letter code for valve outlet, type of by-pass, inlet & Ambient Temperature Range ? Letter code for valve...

Open the catalog to page 2

All Teddington Controls catalogs and technical brochures

  1. QW

    4 Pages

  2. DCA/B

    1 Pages

  3. 38000

    2 Pages

  4. GM

    3 Pages

  5. DSO

    2 Pages

  6. DSS

    2 Pages

  7. DCA/A

    2 Pages

  8. LTSA

    2 Pages

  9. LTATESA

    2 Pages

  10. SOV

    2 Pages

  11. 52000

    2 Pages

  12. 51000

    2 Pages

  13. MSV

    2 Pages

  14. ATESA 203L

    2 Pages

  15. COMSA

    2 Pages

  16. TESA

    2 Pages

  17. GBR

    2 Pages

  18. FrostSentry

    2 Pages

  19. CombiSave

    2 Pages

  20. DST

    2 Pages

  21. 54000

    2 Pages

  22. KBB

    2 Pages

  23. TESA 2394

    2 Pages

  24. CSV

    2 Pages

  25. ATESA 105

    2 Pages

  26. 53000

    2 Pages

  27. KBB Adaptors

    1 Pages