COMSA
2Pages

{{requestButtons}}

Catalog excerpts

COMSA - 1

TEDDINGTON APPLIANCE CONTROLS LTD COMSA 006 COMBINATION VALVES ? Approved CE, CSA ? (40”) WG Max. Pressure 150mbar ? 1/2psi Maximum Inlet Pressure ? Temperature Differential ±10°C (±18°F) ? 120°C Ambient Temperature (10°F - 250°F) -14°C ? Mounting Positions Universal ? Available for Electronic Ignition Switch ? for Natural, Towns and LPG Gases Suitable ? Knob Available Standard Application The Teddington Appliance Controls Combustion Valve combines a tap, flame safety device and precision thermostatic gas control. With CSA and CE approval, the control is deigned to function on a wide range of catering Operation appliances. This consists of pushing the spindle in to clear the niting Physical Description followed by rotation to the ignition position. The spindle is then pushed in to allow gas to the pilot. The The COMSA body is constructed of aluminium or aluminium and brass, depending on type, and is connected to the sensor by a copper capillary. COMSA's are available with inlet, outlet and pilot temperature settings are obtained by further rotation of the spindle. Operating times arrangement to suit virtually all-standard appliances, Opening 20sec. maximum (depending upon application) connections are illustrated overleaf. Closing 60sec. maximum (depending upon application) Capillary lengths: 762, 1219 and 1651mm Maximum Phial Temperature 315°C (600°F) cooking version 60°C (140°F) space heating version

Open the catalog to page 1
COMSA - 2

Connections Inlet Outlet 1 FLANGE MOUNT 1/4NPT FLANGE MOUNT 1/4 NPT 1/8 NPT 1/4 NPT 1/8 NPT 1/4 NPT FLANGE MOUNT 1/8 NPT 1/4 NPT 1/4 NPT Pilot 1/8 NPTF 1/8 NPTF 1/8 NPTF N/A N/A 1/8 NPTF Magnet nut 11/32-2 START 11/32-2 START 11/32-2 START N/A N/A 11/32-2 START By-pass FLOW Graph to show varied inlet pressure vs flow Btu/hvs pressure drop Ambient temp Model shown COMSA006R (Note: inlet, outlet and pilot positions vary according to model. Please contact a sales representative for further details) Outlet By-pass COMSA 006F COMSA 006K COMSA 006PL COMSA 006Q COMSA 006R COMSA 006T Dimensions in...

Open the catalog to page 2

All Teddington Controls catalogs and technical brochures

  1. QW

    4 Pages

  2. DCA/B

    1 Pages

  3. 38000

    2 Pages

  4. GM

    3 Pages

  5. DSO

    2 Pages

  6. DSS

    2 Pages

  7. DCA/A

    2 Pages

  8. LTSA

    2 Pages

  9. LTATESA

    2 Pages

  10. SOV

    2 Pages

  11. 52000

    2 Pages

  12. 51000

    2 Pages

  13. MSV

    2 Pages

  14. ATESA 203L

    2 Pages

  15. TESA

    2 Pages

  16. GBR

    2 Pages

  17. FrostSentry

    2 Pages

  18. CombiSave

    2 Pages

  19. DST

    2 Pages

  20. 54000

    2 Pages

  21. FFD

    2 Pages

  22. KBB

    2 Pages

  23. TESA 2394

    2 Pages

  24. CSV

    2 Pages

  25. ATESA 105

    2 Pages

  26. 53000

    2 Pages

  27. KBB Adaptors

    1 Pages