Catalogo 810 2016 - 1

Series 810 Direct Acting Series 810 Direct Acting Other Series 800 Steam Regulators Typical Installation Series 850 Steam supply Safety valve Stop valve Stop valve Reduced Steam Pressure Direct Acting Steam PRV Steam trap with Strainer According to the valve size selected and the required spring range in Sizing the Regulator, the following selection guide will provide a code for the exact specification of the valve. Pilot operated High capacity High Accuracy Ultracompact Low weight High capacity, low droop. Specially suited for sterilizer applications. Direct acting Low cost Higher capacities than the 810 Series Body Material Material Cast Iron Cast Bronze Stainless Steel Spring Color Black Silver Red Copper Yellow Green Blue Seat Type Code K S R C Y G B Material Metal-to-metal Composition disc (PTFE) Exclusive North American Representantive 19101 SW 108th Ave. Unit # 19Miami , FL 33157 PH: 305-256-0050 FAX: 305-256-0150 Example: For the valve selected in the example, a 3/4“ regulator with a 25-80 regulating range spring, and metal-to-metal seal type; the selection code from Sizing the Regulator would be: 810-CI-Y-0.

Open the catalog to page 1
Catalogo 810 2016 - 2

Series 810 Direct Acting •The Series 810 direet-aeting regulators are ideal for pressure control of equipment with Iow to médium capacities, providing a lower cost, compact solution to the steam pressure control of autoclaves, steam irons, laundry mangles and sterilizers. •Series 810 regulators are used to reduce the steam pressure from distribution lines (100-200 psig) to lower operating pressures (10-140 psig). Body and Seal Selection Main Advantages Item Spring Range Selection Spring Color • Excellent Tight Shut-Off, obtained through a pivoted disc lapped against the seat until obtaining...

Open the catalog to page 2
Catalogo 810 2016 - 3

Series 810 Direct Acting Series 810 Direct Acting medium capacities, providing a lower cost, compact solution to the steam pressure control of autoclaves, steam irons, laundry mangles and sterilizers. EXAMPLE: A steam cooker with a 45 psig design pressure requires a PRV to lower the inlet pressure from 125 psig to 30 psig, while consuming 600 lbs/hr of steam. Choose the correct PRV size, so that the shut-off pressure does not exceed 40 psig, while being able to provide the capacity and regulated pressure required. Critical Flow P2 P ≤.58 P1 1 Saturated Steam (100-200 psig) to lower...

Open the catalog to page 3
Catalogo 810 2016 - 4

Series 810 Direct Acting Safety valve TEI7 Reduoed Steam Pressure Selection According to the valve size selected and the required spring range in Sizing the Regulator, the following selection guide will provide a code for the exact specification of the valve. Seat Type Example: For the valve selected in the example, a 3/4“ regulator with a 25-80 regulating range spring, and metal-to-metal seal type; the selection code from Sizing the Regulator would be: 810-CI-Y-0.

Open the catalog to page 4
Catalogo 810 2016 - 5

Series 810 Direct Acting Series 810 Direct Acting medium capacities, providing a lower cost, compact solution to the steam pressure control of autoclaves, steam irons, laundry mangles and sterilizers. EXAMPLE: A steam cooker with a 45 psig design pressure requires a PRV to lower the inlet pressure from 125 psig to 30 psig, while consuming 600 lbs/hr of steam. Choose the correct PRV size, so that the shut-off pressure does not exceed 40 psig, while being able to provide the capacity and regulated pressure required. Critical Flow P2 P ≤.58 P1 1 Saturated Steam (100-200 psig) to lower...

Open the catalog to page 5
Catalogo 810 2016 - 6

Series 810 Direct Acting Series 810 Direct Acting Other Series 800 Steam Regulators Typical Installation Series 850 Steam supply Safety valve Stop valve Stop valve Reduced Steam Pressure Direct Acting Steam PRV Steam trap with Strainer According to the valve size selected and the required spring range in Sizing the Regulator, the following selection guide will provide a code for the exact specification of the valve. Pilot operated High capacity High Accuracy Ultracompact Low weight High capacity, low droop. Specially suited for sterilizer applications. Direct acting Low cost Higher...

Open the catalog to page 6