General Information
Model: HGA2424ZCZ
Refrigerant: R404A
Test Conditions: EN12900 ASERCOM
Test Voltage: 208V ~ 50HZ and 230V ~ 60HZ
Return Gas Temperature: 20°C (68°F)
Motor Type: CSR
Performance Information- Condensing Temperature and Evaporator Temperature are key parameters affecting performance.
- Performance metrics include Watts (Capacity), Watts (Power), and Amps across various temperature conditions.
- For 208V ~ 50HZ:
- At -40°C Evap Temp, capacity ranges from 380W to 123W as Condensing Temp increases from 30°C to 70°C.
- Power consumption increases from 320W to 540W, and current ranges from 1.96A to 2.83A.
- For 230V ~ 60HZ:
- At -40°C Evap Temp, capacity ranges from 466W to 157W as Condensing Temp increases from 30°C to 70°C.
- Power consumption increases from 377W to 608W, and current ranges from 1.69A to 2.60A.
Coefficients for Performance Calculation
The performance is calculated using a polynomial equation with coefficients for capacity, power, and current. The coefficients vary between the two test conditions (208V ~ 50HZ and 230V ~ 60HZ).
Key Observations- Higher condensing temperatures generally lead to decreased capacity and increased power consumption.
- Performance varies significantly between the two test voltages, indicating the importance of matching the compressor to the correct electrical supply.