Specifche Tecniche Alimentazione • Valori nominali: 24-240 Vca-cc • Vcc con polarita invertibili Comunicazione • Uscita RS485 con protocollo Modbus RTU Ingressi • 2 ingressi RTD Pt100 (IEC 751) 3 fili • 3 ingressi CT1, CT2, CT3 da 0.8 a 5.2 A • Collegamenti su morsettiere estraibili • Canali d'ingresso protetti contro i disturbi elettromagnetici • Compensazione cavi per sonde fino a 500 m (1 mm2) Uscite • 1 rele per ALARM (pre-allarme) Oil e Winding • 1 rele per TRIP (sgancio) Oil e Winding • 1 rele per FAN (ventilazione) • 1 rele per PUMP (pompe) • 1 rele per guasto sonde o anomalia di funzionamento (FAULT) • Rele di uscita con contatti da 5A-250 Vca cos$=1 Test e prestazioni • Costruzione in accordo alle normative CE • Protezione contro i disturbi elettromagnetici CEI-EN61000-4-4 • Isolamento: maggiore di 100 Mohm a 500 Vcc tra GND e terminali • Rigidita dielettrica: 2 KV RMS a 50/60 Hz per un minuto • Linearita: ± 0,5% valore fondo scala • Risoluzione: 1°C • Precisione: - Temperatura "Oil" ± 1% v.f.s. ±1 digit - Temperatura "Winding" ± 1% v.f.s. ±1 digit • Temperatura di lavoro: da -20°C a +60°C • Umidita ammessa: 90% senza condensa • Contenitore in PPO autoestinguente UL 94V0 • Pellicola frontale policarbonato IP50 • Assorbimento: 7VA • Memoria dati: 10 anni minimo • Linearizzazione digitale segnale sonde • Circuito di auto-diagnosi • Opzione: tropicalizzazione Visualizzazione e gestione dati • 2 display 13mm a 3 cifre per visualizzazione temperature e messaggi • 1 led per ALARM per segnalazione di preallarme per sovratemperatura • 1 led per TRIP per segnalazione di sgancio per sovratemperatura • 1 led per FAULT per segnalazione guasto • 1 led per FAN per segnalazione ventilazione forzata • 1 led per PUMP per segnalazione pompe di ricircolo olio • 1 led per RS per segnalazione comunicazione RS485 Modbus RTU in corso • Range di temperature: - da -40°C a +200°C per "Oil" - da -40°C a +200°C per "Winding" • 2 soglie per canale "Oil" • 2 soglie per canale "Winding" • 4 soglie per controllo ventilazione ON-OFF • Diagnostica sonde (Flt) • Segnalazione di errata programmazione • Selezione tra scansione automatica canali e manuale • Memoria massime temperature raggiunte dai canali, allarmi e guasto sonde • Tasto frontale per il reset degli allarmi Dimensioni • 144 x 72 mm DIN 43700 prof. 131 mm (compreso morsettiera) • Foro pannello 139 x 67 mm Technical Specifications Power Supply • Rated values: 24-240 Vac-dc • Vdc with reversible polarities Communication • RS485 output with Modbus RTU protocol Inputs • 2 inputs RTD Pt100 (IEC 751) 3 wires • 3 inputs CT1, CT2, CT3 from 0.8 to 5.2 A • Removable rear terminals • Input channels protected against electromagnetic noises and spikes • Sensor length cable compensation up to 500 m (1 mm2) Outputs • 1 relay for ALARM (alert) Oil and Winding • 1 relay for TRIP (trip) Oil and Winding • 1 relay for FAN (ventilation) • 1 relay for PUMP (pumps) • 1 relay for sensor fault or working anomaly (FAULT) • Output contacts capacity: 5A-250 Vac cos&=1 Tests and performances • Assembling in accordance with CE rules • Protection against electromagnetic noises CEI-EN61000-4-4 • Insulation: higher than100 Mohm at 500 Vdc between GND and terminals • Dielectric strenght: 2 KV RMS at 50/60 Hz for one minute • Linearity: ± 0,5% value full scale • Resolution: 1°C • Accuracy: - Oil temperature ± 1%o full scale value ±1 digit - Winding temperature ± 1%o full scale value ±1 digit • Ambient operating temperature: from -20°C to +60°C • Humidity: 90%> non-condensing • PPO UL 94V0 self-extinguishing housing • Polycarbonate frontal film IP50 • Burden: 7VA • Data storage: 10years minimum • Digital linearity of sensor signal • Self-diagnostic circuit • Option: tropicalization Displaying and data management • 2 displays 13 mm with 3 digits for displaying temperatures and messages • 1 led ALARM for alert signal for overtemperatures • 1 led TRIP to indicate trip for overtemperatures • 1 led for FAULT to indicate fault • 1 led for FAN to indicate forced ventilation • 1 led for PUMP to indicate oil recirculation pumps • 1 led for RS to indicate RS485 Modbus RTU communication in progress • Temperature monitoring: - from -40°C to +200°C for Oil - from -40°C to +200°C for Winding • 2 thresholds for "Oil" channel • 2 thresholds for "Winding" channel • 4 ON-OFF thresholds for FAN control • Sensors diagnostic (Flt) • Wrong programming automatic display • Setting of automatic and manual channels scanning • Maximum storage channels reached temperatures, alarm and sensor fault • Frontal alarm reset push button Dimensions • 144 x 72 mm DIN43700 depth 131 mm (terminals inclu

 Open the catalog to page 1

All TECSYSTEM srl catalogs and technical brochures

  1. T1048 ETH

    2  Pages

  2. NT538 ETH

    2  Pages

  3. NT935 ETH

    2  Pages

  4. CONV ETH

    1  Page

  5. TCK

    1  Page

  6. PTFE

    1  Page

  7. PTSP

    1  Page

  8. PTO

    1  Page

  9. PTSW

    3  Pages

  10. PTSE

    1  Page

  11. PTC

    1  Page

  12. PT73

    1  Page

  13. VRT600

    2  Pages

  14. VRT200

    2  Pages

  15. MM453 AD

    2  Pages

  16. MT4X4 D

    2  Pages

  17. T512

    2  Pages

  18. NT538 AD

    2  Pages

  19. T412 2025

    2  Pages

  20. NT133-3

    2  Pages

  21. NTF999

    2  Pages

  22. T154

    2  Pages

  23. NT935 AD

    2  Pages

  24. NT511 AD

    2  Pages

  25. NT539

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.