1. Catalogs
  2. TECSUP
  3. Inverter pure sinus

Inverter pure sinus

Inverter pure sinus
1 / 17 PagesView full catalog

Inverter pure sinus

Product catalog summary
Important Safety Instructions
It is essential to read and retain safety instructions before using the inverter. The inverter must be kept away from rain, snow, and dust, and its ventilation openings should remain unobstructed. Proper wiring is crucial to prevent fire or electric shock, and the inverter should not be installed near batteries or flammable materials.
Precautions with Batteries
Handle battery acid carefully, avoiding sparks or flames near batteries. Remove metal jewelry to prevent burns from short-circuiting.
Functional Characteristics
The inverter offers a pure sine wave output with high efficiency (90-94%) and can handle reactive loads. It includes protections against over-voltage, low voltage, overheating, and short-circuits, suitable for power tools and various equipment.
Electrical Characteristics
Specifications for 12 VDC and 24 VDC models include nominal and peak power, input/output voltage, frequency, efficiency, and dimensions. LED indicators show operation status and overheating protection.
Installation and Operation
Install the inverter in a dry, cool, ventilated area, away from batteries and flammable materials. Keep DC wiring connections short to minimize voltage drop, and ensure proper earthing to prevent electrocution.
DC Wiring Connections
Recommended cable sizes and fuses are specified for different models to ensure optimal performance. Connections should be tight to prevent overheating.
AC Earthing
The AC outlet must be grounded, and differential circuit breakers are recommended for certain installations.
Usage
Ensure the main switch is off before operation and use the remote control correctly.
Inverter Operation Instructions
Switch the inverter to the ON position using the front face switch to supply alternating current. Turn on multiple appliances sequentially to avoid power peaks. The inverter performs an auto-diagnostic upon switching ON, indicated by beeps and LED lights. A final beep and green indicators confirm correct operation. Switching OFF stops the inverter and extinguishes all LED lights.
Charge Test
Switch the inverter ON to test charging. Use a voltmeter that reads true RMS for precise current measurement.
Troubleshooting Guide
  • No AC Power: Red LED indicates over or low input voltage. Check and adjust input voltage or recharge the battery.
  • Intermittent Blinking: Indicates thermal shutdown. Improve ventilation and ensure unobstructed ventilation shafts.
  • Steady Light: Indicates short circuit or overload. Check wiring and reduce load.
Maintenance
Minimal maintenance is required. Clean the exterior with a damp cloth and periodically tighten DC input terminal screws.
Warranty
The product is guaranteed against material and workmanship defects for two years from purchase. The warranty is void if the inverter is damaged or modified improperly.
Warnings
Do not open or dismantle the inverter to avoid electrical shock or fire risks.
Compliancy Declarations
Tecsup provides compliance certificates for EU, FCC, e Marking, and UL 458 standards.
Contact Information
TECSUP, 32 route des Moulins, BP116, 74410 Saint-Jorioz, Annecy, France. Website: www.tecsup.fr
See more

Catalog excerpts

Inverter pure sinus-2

Inverter TECSUP – Inverter – User manual 80300100 A – P 2 / 17 1 Important safety Instructions Warning Before using the inverter, read and save the safety instructions. 1.1 General safety instructions 1-1-1 Do not expose the inverter to rain, snow, spray, bilge or dust. To reduce risk of hazard, do not cover or obstruct the ventilation openings. Do not install the inverter in a zero-clearance compartment. To avoid a risk of fire or electric shock, make sure that the existing wiring is in good electrical condition; and that wire size is not undersized. Do not operate the inverter with damaged...

 Open the catalog to page 2
Inverter pure sinus-3

Inverter TECSUP – Inverter – User manual 80300100 A – P 3 / 17 2 Functional Characteristics • Pure Sine wave output (THD < 3%). • Output frequency: 50/60 Hz switch selectable. • Low consumption in “Power saving mode”. • Totally isolated on inlet and on outlet. • High efficeincy: 90 to 94 %. • Capable of driving highly reactive & capacitive loads at the start moment. • 3 LED indicators with tri-color display, all operation status.. • Loading controlled cooling fan. • Built in advanced microprocessor to make friendly interface with user. • Protections : - Input over voltage and input low voltage...

 Open the catalog to page 3
Inverter pure sinus-4

Inverter TECSUP – Inverter – User manual 80300100 A – P 4 / 17 2.2 Electrical Characteristics Version 12 VDC / 230 VAC Model (nominal power) 600 W 1000 W 1500 W 2000 W 3000 W Reference CPS 600 12 CPS 1000 12 CPS 1500 12 CPS 2000 12 CPS 3000 12 Peak Output power 800 W 2000 W 3000 W 4000 W 6000 W Input voltage 12 VDC Output voltage 220 / 230 / 240 VAC, +/-3% Frequency (switch selectable) 50 / 60 Hz +/-0,05% Output waveform Sinusoïdal wave < 3% DHT Efficiency 90 % 91 % 90 % 91 % 90 % No load current draw 0,83 A 1,20 A 1,40 A 2,64 A 2,80 A Stand-by current draw -- 0,25 A 0,28 A 0,60 A 0,50 A Input...

 Open the catalog to page 4
Inverter pure sinus-5

Inverter TECSUP – Inverter – User manual 80300100 A – P 5 / 17 Model (nominal power) 600 W 1000 W 1500 W 2000 W 3000 W Reference CPS 600 24 CPS 1000 24 CPS 1500 24 CPS 2000 24 CPS 3000 24 Peak Output power 800 W 2000 W 3000 W 4000 W 6000 W Input voltage 24 VDC Output voltage 220 / 230 / 240 VAC, +/-3% Frequency (switch selectable) 50 / 60 Hz +/-0,05% Output waveform Sinusoïdal wave < 3% DHT Efficiency 93 % 93 % 93 % 94 % 93 % No load current draw 0,43 A 0,60 A 0,70 A 1,32 A 1,50 A Stand-by current draw -- 0,15 A 0,15 A 0,25 A 0,35 A Input level indicator Output level indicator LED red / orange...

 Open the catalog to page 5
Inverter pure sinus-6

Inverter TECSUP – Inverter – User manual 80300100 A – P 6 / 17 2.3 Volume Models 600 W – 1000 W – 1500 W

 Open the catalog to page 6
Inverter pure sinus-7

Inverter TECSUP – Inverter – User manual 80300100 A – P 7 / 17 Models 2000 W – 3000 W

 Open the catalog to page 7
Inverter pure sinus-8

Inverter TECSUP – Inverter – User manual 80300100 A – P 8 / 17 3 Introduction This range of DC/AC inverters are part of the mobile alternative power supply systems, the most advanced available on the market today. To attain these optimal performances, the inverter must be installed correctly. Pleas read the instructions in this manual before using the inverter. 3.1 Operations on the front face Model 600 W Model 1000 W & 1500 W Model 2000 W & 3000 W Switch On / Off / Remote -Before using the inverter, make sure the main switch is « Off ». - Before using the remote control, make sure that the sitch...

 Open the catalog to page 8
Inverter pure sinus-9

Inverter TECSUP – Inverter – User manual 80300100 A – P 9 / 17 Current voltage reading 12 VDC 24 VDC Led red (flashes slow) 10.5 to 10.9 21.0 to 21.8 Led red 10.9 to 11.3 21.8 to 22.6 Led orange 11.3 to 12.0 22.6 to 24.0 Led green 12.0 to 14.0 24.0 to 28.0 Led orange (flashes slow) 14.0 to 14.7 28.0 to 29.4 Led orange (flashes rapidly) > 14.7 > 29.4 Charge levels : Consomption display AC (Watts) Led black Led green L ed orange Led red Led red (flash) CPS 600 0 to 30 30 to 200 200 to 450 450 to 580 > 580 CPS 1000 0 to 50 50 to 330 330 to 750 750 to 960 > 960 CPS 1500 0 to 75 75 to 495 495 to 1125...

 Open the catalog to page 9
Inverter pure sinus-10

Inverter TECSUP – Inverter – User manual 80300100 A – P 10 / 17 3.2 Operations on the rear face Remote Control connector (remote port) : Available on option. Before using the remote control be sure that the main switch is on the « remote » position. 600 W model exclusivly : ON/OFF terminal for remote control In order to make the remote control work, it is necessary that the switch be at the OFF position on the face of the inverter. Before connecting, make sure that the remote is on the OFF position. Make the connection between the remote and the terminal marked « Remote port » at the rear of...

 Open the catalog to page 10
Inverter pure sinus-11

Inverter TECSUP – Inverter – User manual 80300100 A – P 11 / 17 Earthing the chassis Connect the earth terminal of the chassis to the chassis of the vehicle via an 8 mm2 section of cable. 3.3 Installation Where to install it : • Dry : Do not allow water to splash or drip onto the inverter. • Cool : Ambiant air temperature should be between 0°C & 40°C. The cooler the better. • Safety : Do not install the inverter near or in the battery compartment where flammable fumes exist, such as fuel storage areas or engine compartments. • Ventilated : Allow for at least 2,5 cm clearance minimum around the...

 Open the catalog to page 11
Inverter pure sinus-12

Inverter TECSUP – Inverter – User manual 80300100 A – P 12 / 17 The following recommended cables are for the best performance of the inverter. Model Recommended Section Recommended Fuse CPS 600 12 25 mm2 100 A CPS 600 24 16 mm2 50 A CPS 1000 12 35 mm2 150 A CPS 1000 24 25 mm2 80 A CPS 1500 12 35 mm2 200 A CPS 1500 24 25 mm2 100 A CPS 2000 12 70 mm2 250 A CPS 2000 24 50 mm2 125 A CPS 3000 12 100 mm2 400 A CPS 3000 24 70 mm2 200 A Connect the cables to the power input terminals on the front panel of the inverter. The red terminal is positive (+) and the black terminal is negative (-). Insert the...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.