Vibrations dosimeter
4Pages

{{requestButtons}}

Catalog excerpts

Vibrations dosimeter - 1

WHOLE-BODY VIBRATION DOSIMETER User friendly operation and use (even by non-experts) Automatic computation of the exposure levels as defined in the European directive 2002/44/CE Automatic measurement of exposure time Direct assess to the measurement results using a laptop or PocketPC Very short learning curve Reasonable cost Automatic detection and removal of unwanted effects Developed in partnership with INRS (Research Center for Safety, France)

Open the catalog to page 1
Vibrations dosimeter - 2

Compliance with standards The EVEC whole-body vibration dosimeter has been developed in partnership with INRS (Institut National de Recherche et de Sécurité, France) under the agreement No.5061249. INRS has verified that this device can be used for whole-body vibration exposure measurements. Acceptance testing has been carried out according to EN ISO 8041:2005, section 12. Each manufactured device is tested according to ISO8041:2005, section 13 Frequency Weightings Wd along X and Y axis Wk along Z axis Those frequency weightings conform to ISO2631 which is the standard referred to for...

Open the catalog to page 2
Vibrations dosimeter - 3

Sensor Physical Characteristics Dimensions: diameter 205 mm, height: 12 mm (complies with ISO10326-1) Weight: 350 grams Environment Sensor operating range: from -10° to 50° (0° to 40° when charging) C C C C Charger Input: Wireless Link Bluetooth® Class 2 Communication up to 30 m, open field Nominal emission power: +4 dBm Nominal sensitivity: -84 dBm ISM Band 2.4 GHz Electromagnetic Compatibility Radiated emissions tested according to EN 55022 Immunity tested according to EN 61000-4-8/6/2/3

Open the catalog to page 3
Vibrations dosimeter - 4

Sensor Dynamics Parameter Error – weighted accelerations along X, Y and Z Sine wave Amplitude: 1m/s2 Frequency: 15.915Hz T° =23° C Sensitivity to temperature – weighted accelerations Ambient temperature Surface temperature Frequency weighting and response Linearity Error - Amplitude Linear Measuring Range Response to normalized pulses – tolerance on RMS values Resolution of exposure time measurements Time measurement accuracy Electrical crosstalk Mechanical crosstalk Accelerometer resonant frequency Chocks resistance

Open the catalog to page 4

All TECORA catalogs and technical brochures

  1. EMITEST ISO

    4 Pages

  2. Sentinel PM

    1 Pages

  3. Echo PM

    1 Pages

  4. Charlie HV

    1 Pages

  5. Echo Hi Vol

    2 Pages

  6. Easy Gas

    1 Pages

  7. Isostack G4

    4 Pages

  8. Isofrost 2

    1 Pages

  9. Igloo

    1 Pages

  10. Delta MK2

    3 Pages

  11. Bravo Series

    1 Pages

  12. Flowcal Air

    3 Pages