Skypost PM HV
1Pages

{{requestButtons}}

Catalog excerpts

Skypost PM HV - 1

Immission Line 2.010.01 Sequential Station for Particulate Matter Skypost PM HV * Optional features Skypost PM HV has up to 50 l/min flow rate capacity and is suitable for dust sampling with LVS PM10 2.3 m3/h sampling head, according to EN 12341 norm and LVS PM2.5 2.3 m3/h sampling head, according to EN14907 norm. The modularity of the sampling head allows to use the USEPA 40, CFR Part 50 sampling head as well. The completely straight suction tube with its round shape and the separation of the storage filter zone from internal and radiant source of heat, allow to collect and keep the integrity of the pollutants. A ventilation and differential thermoregulated heating system allows the instrument to operate even in extreme ambient conditions. Technical Characteristics Flow rate range Pump type Power supply Dimensions (b x b x h) Weight Instrument P/N Telescopic tripod GSM modem for remote control (with RS-232 abilitation) RS-232 abilitation for PC program 10 - 50 l/min Rotary vane 6m3/h 220 V 50 Hz 450 x 510 x 610 mm 42 kg AA99-014-0030SP AA99-013-9906SP AA99-014-9910SP AA99-014-9911SP Ed. 3 05/11 - Technical specifications may change without previous warning · Certified by TÜV in accordance with EN12341 and DM60 norms · Main applications: - Total particulate matter - PM10, PM2.5, PM1 fractions - Heavy metals · 16 filter capacity · Electronic flow rate control · Measuring sensors for: - Atmospheric pressure - Pressure drop on filter - Ambient temperature - Dry gas meter temperature · Volumetric measurement with dry gas meter within ±2% precision · Sampling probe ventilation system, to guarantee a differential temperature between the filter and the sample inlet of max. 5° C, in accordance with EN14907 · Sample conditioning signal for: - wind direction and velocity * - external signal * (i.e. rain) · RS232 interface · Built-in printer · Remote control with dedicated software Skypost PM HV is an automatic outdoor station for continuous atmospheric particulate monitoring using the sampling method on 47mm diameter filter membrane. The sequential substitution system of the filtering membrane with 16 membranes capacity and the electronic flow rate controller, allow continuous, unattended operations as well as an easy replacement of the exposed filters without interrupting the sampling. 2.010.01 Main Characteristics Product Data Immission Line TECORA - Headquarter: 211-215 rue la Fontaine, 94134 Fontenay Sous Bois Cedex - FRANCE. Italian office: Via A. Volta 22, 20094 Corsico (Mi) - ITALY www.tecora.com Approved

Open the catalog to page 1

All TECORA catalogs and technical brochures

  1. EMITEST ISO

    4 Pages

  2. Sentinel PM

    1 Pages

  3. Echo PM

    1 Pages

  4. Charlie HV

    1 Pages

  5. Echo Hi Vol

    2 Pages

  6. Easy Gas

    1 Pages

  7. Isostack G4

    4 Pages

  8. Isofrost 2

    1 Pages

  9. Igloo

    1 Pages

  10. Delta MK2

    3 Pages

  11. Bravo Series

    1 Pages

  12. Flowcal Air

    3 Pages