1. Catalogs
  2. TECORA
  3. Hydra Dual Channel

Hydra Dual Channel

Hydra Dual Channel

Hydra Dual Channel

Product catalog summary
Main Characteristics:
  • Dual channel sampler suitable for PM10, PM2.5, and PM1 sampling on two independent channels.
  • Operating flow rate range: 0.8 to 2.5 m³/h.
  • Sampling on 47mm diameter filter membrane for further analysis.
  • Temperature control of air flow to minimize volatile material losses.
  • Cooling system for sampled filters to ensure sampling stability.
  • Online monitoring of all parameters related to the sampling process with diagnostic warnings for anomalies.
  • Data storage on internal buffer with local control via RS232 serial interface and complete remote control via Modem/GSM.
Sampling Configurations:
  • Simultaneous PM10 and PM2.5 sampling with specific inlets on independent membranes.
  • Single PM10 sampling inlet with a PM2.5 in series impactor.
  • Sampling with two identical inlets on independent membranes.
  • Single inlet sampling on two independent membranes or two sampling lines at different temperatures.
Technical Specifications:
  • Filter Loader/Unloader capacity: 36 filter cartridges (72 on demand).
  • Filter cartridges: ß equivalent spot area 11.95 cm².
  • Operating flow rate: Programmable range 0.8 to 2.5 m³/h independently on each channel.
  • Max pressure drop: 40 kPa at 2.3 m³/h on each channel.
  • Flow rate measurement precision: ± 1% of the measured value.
  • Flow rate measurement accuracy: < 2% of the measured value.
  • Power supply: 230 Vac (± 10%) 50 Hz single-phase, 1000 W max.
  • Compressed air feeding: 200 to 300 kPa.
  • Operating conditions: Temperature 5-35 °C, Relative Humidity < 85% (no condensation).
  • Storage conditions: Temperature -10 to +55 °C, Relative Humidity < 85% (no condensation).
  • Dimensions and Weight: Sampling unit 430 x 540 x 240 mm, 42 kg; Vacuum pump unit 350 x 550 x 200 mm, 10 kg; Service Air unit 180 x 420 x 240 mm, 18 kg.
Conformity and Standards:
  • Conforms to European Directives: 73/23/EC (low-voltage), 98/37/EC (machinery safety), 89/336/EC (Electromagnetic Compatibility).
  • Technical harmonized regulations: EN 61010-1, EN 61326-1, EN 61000-3-2, EN 61000-3-3.
See more

Catalog excerpts

Hydra Dual Channel-1

Immission Line 2.224.01 Dual Channel Sampler for TSP · Suitable for PM10, PM2.5, PM1sampling inlet on two indipendent channels · Operating flow rate range 0.8 ÷ 2.5 m3/h · Sampling on 47mm diam. filter membrane for further analysis · Temperature control of the air flow to minimize the volatile material losses · Cooling system for the sampled filters Unloader, to assure sampling stability · On line monitoring of all parameters related to the sampling process, with relative diagnostic warnings of possible anomalies · Sampling and measurement data storage on internal buffer · Local control with RS232 serial interface · Complete remote control via Modem/GSM Hydra is a dual channel reference sampler which allows the simultaneous sampling on two indipendent sampling lines of different granulometric fractions (i.e. PM10 and PM2.5). Further, Hydra allows the sampling on a single inlet. In this application the sample can be collected on 2 different filter membranes, suitable for different kind of analysis. Hydra is a valid support for metrological studies in the PMx sampling field. The instrument is available with different configuration: 1. Sampling with 2 identical sampling inlets on 2 indipendent membranes 2. Sampling with a single sampling inlet on 2 indipendent membranes 3. Sampling with a single sampling inlet on 2 sampling lines at different temperature 4. PM10 (or PM2.5) sampling with different standard sempling inlets on 2 indipendent membranes 5. Simultaneous PM10 and PM2.5 sampling with 2 specific sampling inlets on 2 indipendent membranes 6. PM10 and PM2.5 sampling with a single PM10 sampling inlet and a PM2.5 in series impactor. For further information regarding applications, please contact us Ed. 0 09/12 - Technical specifications may change without previous warning Main characteristics Product Data Immission Line 2.224.01 TECORA - Headquarter: 211-215 rue la Fontaine, 94134 Fontenay Sous Bois Cedex - FRANCE. Italian office: Via A. Volta 22, 20094 Corsico (Mi) - ITALY www.tecora.com HYDRA Dual Sampler

 Open the catalog to page 1
Hydra Dual Channel-2

Im m ission Line 2 .2 2 4 .0 2 Te c h ni c a l Sp ec i f i c a t i o ns Filters Loader/Unloader capacity Filters cartridges Filter membranes Operating flow rate n° 36 filter cartridges (or 72 on demand) ß equivalent spot area 11.95 cm2 (standard - supplied) Ø 47 mm (not supplied) Programmable in the range 0.8 ÷ 2.5 m³/h (indipendently on each of the 2 channels) Max pressure drop 40 kPa at 2.3 m³/h (on each channel) Flow rate measurement precision ± 1% of the measured value (on each channel) Flow rate measurement accuracy < 2% of the measured value (on each channel) Power supply 230 Vac (± 10%)...

 Open the catalog to page 2

All TECORA catalogs and technical brochures

  1. EMITEST ISO

    4  Pages

  2. Sentinel PM

    1  Page

  3. Echo PM

    1  Page

  4. Charlie HV

    1  Page

  5. Echo Hi Vol

    2  Pages

  6. Easy Gas

    1  Page

  7. Isostack G4

    4  Pages

  8. Isofrost 2

    1  Page

  9. Igloo

    1  Page

  10. Delta MK2

    3  Pages

  11. Bravo Series

    1  Page

  12. Flowcal Air

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.