Hydra Dual Channel
2Pages

{{requestButtons}}

Catalog excerpts

Hydra Dual Channel - 1

Immission Line 2.224.01 Dual Channel Sampler for TSP · Suitable for PM10, PM2.5, PM1sampling inlet on two indipendent channels · Operating flow rate range 0.8 ÷ 2.5 m3/h · Sampling on 47mm diam. filter membrane for further analysis · Temperature control of the air flow to minimize the volatile material losses · Cooling system for the sampled filters Unloader, to assure sampling stability · On line monitoring of all parameters related to the sampling process, with relative diagnostic warnings of possible anomalies · Sampling and measurement data storage on internal buffer · Local control with RS232 serial interface · Complete remote control via Modem/GSM Hydra is a dual channel reference sampler which allows the simultaneous sampling on two indipendent sampling lines of different granulometric fractions (i.e. PM10 and PM2.5). Further, Hydra allows the sampling on a single inlet. In this application the sample can be collected on 2 different filter membranes, suitable for different kind of analysis. Hydra is a valid support for metrological studies in the PMx sampling field. The instrument is available with different configuration: 1. Sampling with 2 identical sampling inlets on 2 indipendent membranes 2. Sampling with a single sampling inlet on 2 indipendent membranes 3. Sampling with a single sampling inlet on 2 sampling lines at different temperature 4. PM10 (or PM2.5) sampling with different standard sempling inlets on 2 indipendent membranes 5. Simultaneous PM10 and PM2.5 sampling with 2 specific sampling inlets on 2 indipendent membranes 6. PM10 and PM2.5 sampling with a single PM10 sampling inlet and a PM2.5 in series impactor. For further information regarding applications, please contact us Ed. 0 09/12 - Technical specifications may change without previous warning Main characteristics Product Data Immission Line 2.224.01 TECORA - Headquarter: 211-215 rue la Fontaine, 94134 Fontenay Sous Bois Cedex - FRANCE. Italian office: Via A. Volta 22, 20094 Corsico (Mi) - ITALY www.tecora.com HYDRA Dual Sampler

Open the catalog to page 1
Hydra Dual Channel - 2

Im m ission Line 2 .2 2 4 .0 2 Te c h ni c a l Sp ec i f i c a t i o ns Filters Loader/Unloader capacity Filters cartridges Filter membranes Operating flow rate n° 36 filter cartridges (or 72 on demand) ß equivalent spot area 11.95 cm2 (standard - supplied) Ø 47 mm (not supplied) Programmable in the range 0.8 ÷ 2.5 m³/h (indipendently on each of the 2 channels) Max pressure drop 40 kPa at 2.3 m³/h (on each channel) Flow rate measurement precision ± 1% of the measured value (on each channel) Flow rate measurement accuracy < 2% of the measured value (on each channel) Power supply 230 Vac (±...

Open the catalog to page 2

All TECORA catalogs and technical brochures

  1. EMITEST ISO

    4 Pages

  2. Sentinel PM

    1 Pages

  3. Echo PM

    1 Pages

  4. Charlie HV

    1 Pages

  5. Echo Hi Vol

    2 Pages

  6. Easy Gas

    1 Pages

  7. Isostack G4

    4 Pages

  8. Isofrost 2

    1 Pages

  9. Igloo

    1 Pages

  10. Delta MK2

    3 Pages

  11. Bravo Series

    1 Pages

  12. Flowcal Air

    3 Pages