Specifications Overview
The document provides detailed specifications for a series of motors (UL3, UL6, UL9, UL12, UL15) with a focus on performance, electrical, thermal, and mechanical characteristics. All specifications are subject to a ±10% tolerance.

Performance Specifications
- Winding Type: N and S configurations are available.
- Motor Type: 3-phase synchronous with a maximum voltage of 230 Vac, rms (325 Vdc).
- Peak Force: Ranges from 240 N to 1200 N at 25°C.
- Continuous Force: At 110°C, ranges from 70 N to 350 N; at 105°C, ranges from 67 N to 336 N.
- Maximum Speed: 5.0 m/s to 12 m/s depending on the model.
- Motor Force Constant: 68 N/Arms for N winding and 27.5 N/Arms for S winding.

Electrical Specifications
- Peak Current: Varies from 3.5 Arms to 17.8 Arms at 25°C.
- Continuous Current: At 110°C, ranges from 1.0 Arms to 5.2 Arms; at 105°C, ranges from 1.0 Arms to 4.9 Arms.
- Back EMF: 55.5 Vdc/m/s for N winding and 22.5 Vdc/m/s for S winding.
- Resistance and Induction: Resistance per phase ranges from 15.9 Ω to 3.3 Ω; induction per phase ranges from 13 mH to 2.7 mH.

Thermal Specifications
- Continuous Power Loss: At 110°C, ranges from 67 W to 335 W; at 105°C, ranges from 62 W to 308 W.
- Thermal Resistance: Ranges from 1.3 K/W to 0.26 K/W.
- Temperature Sensor: PTC 1kΩ / NTC.

Mechanical Specifications
- Coil Unit Mass: Ranges from 0.27 kg to 1.13 kg.
- Coil Unit Length: Ranges from 106 mm to 442 mm.
- Magnet Pitch: 42 mm.
- Cable Mass: 0.09 kg/m to 0.105 kg/m.

Additional Information
- Magnet yokes can be butted together for extended applications.
- Mounting instructions and requirements for flatness or parallelism are available in the installation manual.
- CAD files and 3D models can be downloaded from the company's website.

Approvals and Certifications
- The maximum coil temperature for CSA certification is 105°C, while without certification, it is 110°C.
See more

Catalog excerpts

UL SERIES-1

Winding type NSNSNSNSNS Magnet yoke dimensions Magnet yokes can be butted together. direct drive in motion Motor type, max voltage ph-ph 1 These values are only applicable when the mounting surface is at 20°C and the motor is driven at continuous current. If these values differ in your application, please check our simulation tool. 2 Actual values depend on bus voltage. Please check the F/v diagram in our simulation tool. 3 The maximum coil temperature for CSA certification is 105°C. The maximum coil temperature without CSA certification is 1I0°C.

 Open the catalog to page 1
UL SERIES-2

Magnet yokes 94 Optional: Digital Hall Module Optional: Digital Hall Module 7 O3 (2x) DETAIL Hole A Dowelpin For DIN7 O133h8 M 4 (8 deep) (2x) Earth connection 4.5 (2x) Hole O3 (2x) For Dowelpin DIN7 O3h8 DIN 912) O 5.5 (for M5 (Optional use) O 9.2 (6 deep) Magnet yoke 105 M 4 (8 deep) (2x) Earth connection COIL UNITS Magnet yoke Coil unit Power cable O 4.5 O 4.7 Thermal sensor cable 19 9 O 4.7 Thermal sensor cable MAGNET YOKES Mounting instructions and flatness or parallelism requirements can be found in the ironless installation manual. CAD files and 3D models can be downloaded from our website....

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.