TL Series

TL Series

TL Series

Product catalog summary
Specifications:
The document outlines the specifications for a series of motors, identified by TL numbers (TL6, TL9, TL12, TL15, TL18, TL24, TL48). Key parameters include winding type, motor type, maximum voltage, ultimate force, peak force, continuous force, maximum speed, motor force constant, and motor constant. The specifications are provided for different conditions such as temperature and cooling methods.
Performance:
The motors are 3-phase synchronous with a maximum voltage of 400 Vac, rms (565 Vdc). Ultimate force ranges from 450 N to 3600 N, and peak force ranges from 400 N to 3200 N. Continuous force varies depending on whether the coils are water-cooled or not, with values ranging from 200 N to 1680 N. Maximum speed is dependent on the motor type and ranges from 2.4 m/s to 9.8 m/s.
Electrical Characteristics:
Ultimate current and peak current values are provided for magnets at 25°C, with ultimate current ranging from 6.5 Arms to 27.1 Arms and peak current from 5.0 Arms to 20.7 Arms. Continuous current for water-cooled coils at 100°C ranges from 2.26 Arms to 9.4 Arms. Other electrical parameters include back EMF, resistance per phase, induction per phase, and electrical time constant.
Thermal Characteristics:
Continuous power loss for coils at 100°C ranges from 150 W to 1200 W. Thermal resistance and thermal time constant are specified, with thermal resistance ranging from 0.48 K/W to 0.06 K/W and a thermal time constant of 77 seconds. Water cooling flow and pressure drop are also detailed.
Mechanical Characteristics:
Coil unit mass ranges from 1.5 kg to 9.8 kg, and coil unit length from 146 mm to 855 mm. Motor attraction force at 0 A ranges from 950 N to 6400 N. Magnet pitch is specified as 24 mm. Cable mass and types are also provided.
Additional Features:
All TL motors feature integrated cooling channels for easy setup of a liquid-cooled system. Magnet plate dimensions and mounting instructions are provided, with CAD files and manuals available for download from the website.
See more

Catalog excerpts

TL Series-1

TL series Parameter Remarks Sym Unit TL6 TL9 TL12 TL15 TL18 TL24 TL48 Water cooling All TL motors feature integrated cooling channels that allow for the easy setup of a liquid cooled system, at no additional cost. Magnet plate dimensions Le (mm) 192 288 Magnet plates can be butted together. Winding type NSNSNSNSNSNS Q Cable type (sensor) length 1 m d mm (AWG) 4.7 (26) 1 bCNOTION direct drive in motion These values are only applicable when the mounting surface is at 20°C and the motor is driven at continuous current. If these values differ in your application, please check our simulation tool. All specifications ±10% Actual values depend on bus voltage. Please check the F/v diagram in our simulation tool.

 Open the catalog to page 1
TL Series-2

COILUNITS COILUNITS COILUNITS Optional: Digital Hall Module Optional: Digital Hall Module Power cable O 4.7 Thermal sensor cable Slotted Hole O5x0.5 (3 deep) For Dowelpin DIN7 O5h8 (Optional use) R 4.6 O5 (3 deep) Hole For Dowelpin DIN7 O5h8 14.7 For Dowelpin (Optional use)DIN7 O5h8 Hole O5 (312deep) 14.7 (Optional use) For Dowelpin 12 DIN7 O5h8 (Optional use) MAGNET PLATES Hole O5 (3 deep) Mounting Height Mounting Height 40 40 ±0.1±0.1 Power cable Power cable O 4.7 Thermal sensor cable Power cable O 4.7 Thermal sensor cable O 4.7 Thermal sensor cable Magnet plates MAGNET PLATES Slotted Hole...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.