1. Catalogs
  2. TECHSYS - HW a SW, a.s.
  3. Terminal for technology monitoring and controlling

Terminal for technology monitoring and controlling

Terminal for technology monitoring and controlling

Terminal for technology monitoring and controlling

Product catalog summary
Overview
The Storm-04 is a versatile terminal from the Storm family designed for SCADA systems across various sectors such as telecommunications, industry, and power. It integrates seamlessly with existing systems through multiple communication interfaces, supporting tasks like ambient condition monitoring, signal transmission, and remote control.
Basic Characteristics
  • Wide range of inputs and outputs.
  • Expandable via Storm extension modules.
  • Supports numerous 1-Wire bus sensors.
  • Custom functions can be added.
  • Compatible with standard communication protocols for easy integration.
  • Local and remote configuration, parameter setting, and diagnostics.
  • Automatic upgrades and updates.
  • Suitable for installations with grounded backup battery poles.
  • Smart Grid measuring capabilities.
  • Integration with IoT and Cloud solutions.
Communication
  • Supports 1-Wire data bus, RS-232, RS-485, and Ethernet interfaces.
  • Handles multiple communication protocols and directions simultaneously.
  • Data storage capability during communication outages.
  • Time synchronization via communication protocol.
Typical Use Cases
  • Data collection and processing for communication technology providers.
  • RTU with PLC functions for industrial and transport equipment monitoring and control.
  • Building security equipment monitoring.
  • Online data transmission from utility meters (power, gas, heat, water).
  • Power plant monitoring, control, and regulation.
  • Power industry monitoring, control, and automation.
  • Integration into technological components and facilities.
  • OEM product availability for manufacturers and system integrators.
  • Sensor connections for various environmental parameters.
Technical Specifications
  • Digital Inputs: 16x opto-element, passive input.
  • Digital Outputs: 4x relay with switching contact.
  • Data Bus: 2x bus for 1-Wire sensors.
  • Communication Interface: Ethernet, RS-232, RS-485.
  • Build: 9M width plastic case, 35 mm DIN rail mounting.
  • Protection: IP 20.
  • Power Supply: 24 V or 48 V DC with galvanic separation.
  • Service Temperature: -30 to 70 °C.
  • Maximum Ambient Humidity: 95% without condensation.
  • Weight: Max. 150 g.
  • Dimensions: 158 x 90 x 60 mm.
  • EMC Standards: IEC 61000-6-4, IEC 55024, IEC 55022, IEC 61000-6-2.
Communication Protocols
  • RS-232, RS-485: IEC 60870-5-101, Modbus (RTU).
  • Ethernet: IEC 60870-5-104, Modbus TCP, DNP 3.0 TCP.
  • 1-Wire: 1-Wire protocol.
Example Device with 1-Wire Communication
  • Manufacturer and Model: TECHSYS 1W Thermometer.
  • Temperature Measurement Range: -55 to 90 °C.
  • Resolution: Down to 0.0625 °C.
  • Number of Bits: 9 to 12.
  • Connector: WAGO 6-pin.
  • Temperature Sensor: DS18B20.
  • Dimensions: 70 x 70 mm.
  • Color: Grey or black.
See more

Catalog excerpts

Terminal for technology monitoring and controlling-1

Terminal for technology monitoring and controlling Storm-04 is a multi-functional terminal from the Storm family that meets all general standards for SCADA systems in telecommunications, industry, the power sector and other fields. The terminal is equipped with a number of communication interfaces through which it can be easily integrated into customers' existing systems. Typical use includes monitoring ambient conditions and consumption, signal transmission and remote control. Basic Characteristics • broad range of inputs and outputs • easy extension via Storm extension modules • easy installation of a many 1-Wire bus sensors • the ability to add special custom functions • communications interface for easy integration using a number of standard protocols • local and remote configuration, parameter setting and diagnostics • automatic upgrade and update • suitable for installation with a grounded plus or minus backup battery pole • Smart Grid measuring element • easy integration for loT and Cloud solutions • RS-232, RS-485 and Ethernet serial and network interfaces • broad range of standard communication protocols • the ability to communicate in multiple directions simultaneously • data storage when the communication link goes down • time sync via communication protocol • data collection and processing for technology of communication providers • universal RTU with PLC functions for monitoring and controlling equipment in industry and transport • monitoring building security equipment • terminals for on-line transmission of data from power meters and consumption meters for other utilities (gas, heat, water) • power plant monitoring, control and regulation • power industry monitoring, control and automation • delivery for integration into technological components and facilities • available as an OEM product for manufacturers, suppliers and system integrators • connection of sensors for measuring temperature, relative humidity, atmospheric pressure, light intensity, flooding, atmospheric CO content, distance, position and many other parameters Headquarter Prague, Brezinova 640/3a, 186 00 Praha 8, Czech Republic Branch Office Ceske Budejovice, U Vystaviste 1485, 370 05 Ceske Bud

 Open the catalog to page 1
Terminal for technology monitoring and controlling-2

Terminal for technology monitoring and controlling Technical Specifications Digital Output Parameters Communication Protocols (depending on interface) Digital Input Parameters Example of Device with 1-Wire Communication Example of three thermometers connected to a 1-Wire bus Headquarter Prague, Brezinova 640/3a, 186 00 Praha 8, Czech Republic Branch Office Ceske Budejovice, U Vystaviste 1485, 370 05 Ceske Budejovice, Czech Republic

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.