Introduction
The document presents the L3-standard, a LED-based system developed by TechnoTeam for measuring luminance, luminous intensity, and luminous flux. It is designed for high stability and precision in photometric measurements.

Specifications
The L3-standard includes a microcontroller for data transmission via USB, allowing internal monitoring of status, operating hours, and calibration data. It is equipped with a power supply unit and a USB connection cable. The system is compatible with Windows XP and higher, and includes an ActiveX® interface for integration into custom applications.

Calibration and Certification
Each L3-standard is factory-calibrated for luminance and chromaticity coordinates. Calibration certificates for luminous flux and intensity can be provided upon request. Calibration can be traced to national metrology institutes like PTB Germany or METAS Switzerland.

System Features
The L3-standard offers high stability in luminance (<1%/100h) and color (<1nm/100h), independent of room temperature (15°C to 30°C). It provides homogeneous luminance over the outlet opening and is available in standard colors (red, green, blue, yellow, orange, white), with custom colors available on request.

Optional Accessories
Optional accessories include covers for neutral density filters, crowns for luminous intensity distribution, and calibration certificates from accredited laboratories.

Applications
The L3-standard is used for system adjustment, calibration, stability tests, luminous flux calibration, and LID comparison. It is suitable for monitoring multiple LED light sources and ensuring the accuracy of photometric measurements.

Technical Details
The system uses a Peltier device for temperature control and a spectrally matched photodiode for intensity control. It operates at about 2/3 of the LED's rated current, ensuring long-term stability and performance.

Conclusion
The L3-standard provides a reliable and precise solution for LED-based photometric measurements, with extensive calibration options and compatibility with various applications.
See more

Catalog excerpts

Catalogue of L³-standard products-1

Software functions 3 Inside the L -standard, there is a microcontroller which is able to transmit data to the PC via the USB connection. Thus, internal monitoring is possible (e.g. status of the 3 L -standard). Furthermore, also data can be read out such as operating hours, „running since“, the serial number and last calibration value. 3 With the L -standard a small application and a ActiveX® -interface is delivered. With the application the user is able to read the status values transmitted via USB interface. The ActiveX® -interface allows the user to integrate 3 the status values of the L -standard into their own applications. Top attachments for different tasks: end cover with filter adapter (left), Crown with three peaks (asymmetric) and plain end cover (right) Scope of delivery 3 The L -standard is delivered together with a power supply unit. The LED standards should be used only with the power supply unit provided. The connector which is to be plugged to 3 the L -standard provides, in addition, a USB connector. The L3-standard can be connected to a computer via a USB extension cable. standard 3 L -standard of the desired type with plain end cover Factory calibration certificate for luminance and colour coordinates x,y (informative: relative spectral power distribution) 3 Presented by: 3 L -standard mounting support for mounting on optical benches Power supply unit USB-connection cable Software for displaying the internal data (Windows® Version XP and higher, 32Bit) ActiveX® Interface for including in own programs In coorporation with the Department of Science and Technology www.hawk-hhg.de Prof. Dr.-Ing. K. Bobey, MSc. Dipl.-Ing. R. Burdick Optional accessories Upon request the following items can be offered, too: Werner-von-Siemens-Str. 5 98693 Ilmenau GERMANY Cover for neutral density filters Neutral density filters for the adaption of the luminance Tel. +49 3677 4624 0 Fax +49 3677 4624 10 Crown for forming the luminous intensity distribution [email protected] Factory calibration certificate for luminous flux Φ, luminous intensity I and luminous intensity distribution I(ϑ,ϕ) Calibration certificates issued by accredited calibration laboratories (e.g. PTB Germany, METAS Switzerland) 3 L -standard with associated power supply unit and cable, optional accessories in the image www.TechnoTeam.de L 3 LED-based standards for luminance, luminous intensity (distribution) and luminous flux standard

 Open the catalog to page 1
Catalogue of L³-standard products-2

With the l^-standard the TechnoTeam Company offers stable coloured standards for Luminance, Luminous flux and Luminous intensity based on LEDs. The stability of the photometric quantities is achieved through a temperature control containing a Peltier device, and an intensity control containing a spectrally matched photo- diode. In the closed housing, which has an exchangeable end cover, a pre-aged and selected HighPower-LED is used for each L?-standard operated at about 2/3 of its rated current. ■ high stability of the luminance (< 1%/100h) ■ high stability of the dominant wavelength/ ■ stable...