1. Catalogs
  2. Techno Optis Co., Ltd.
  3. UV Radiometer UVR-300

UV Radiometer UVR-300

UV Radiometer UVR-300

UV Radiometer UVR-300

Product catalog summary
Overview: The UVR-300 is a high-performance digital UV radiometer designed for measuring ultraviolet light across various applications. It features high sensitivity, a wide range, and user-friendly operation. The device is suitable for measuring bactericidal lamps, photochemical reactions, photoresist light quantities, and solarization testing.
Specifications: The UVR-300 measures UV light intensity from 0.1 to 280,000μW/cm2. It includes three interchangeable high-sensitivity detectors (UD-250, UD-360A, UD-400) for different wavelength ranges (220-490 nm). The device offers a 4-digit LCD display with auto/manual range selection and an accuracy of ±5% of reading.
Package Contents: The standard package includes the UVR-300 main body, a cap, a leather case, a CD-ROM with USB driver and instruction manual, and an analog output plug. Note that a USB cable is not included.
Applications: The UVR-300 is used in semiconductor manufacturing, printing, solar battery evaluation, product deterioration testing, electrophotography, and biological studies such as erythema and pigmentation treatment.
Light Sources: Compatible light sources include fluorescent sun-lamps, high-pressure mercury-vapor lamps, xenon lamps, and bactericidal lamps, among others.
Measurement Modes: The device supports various measurement modes, including integral irradiance, deviation measurement, and percentage measurement. It also features a correction factor mode for different UV lamps.
Safety and Usage: Users are advised to read the manual carefully to ensure proper and safe use. The device should be connected to the specified power supply voltage, and only specified batteries should be used to avoid fire or electric shock.
Additional Features: The UVR-300 offers USB connectivity for data retrieval and supports continuous measurement with optional software (MT-100) for data storage in CSV format. The device operates within a temperature range of -10 to +40ºC and up to 85% relative humidity.
Dimensions and Weight: The UVR-300 measures approximately 195 mm x 70 mm x 33 mm and weighs about 260 g, including the detector and batteries.
Contact Information: For more details, visit the TechnoOptis website or contact them via phone or email.
See more

Catalog excerpts

UV Radiometer UVR-300-1

formerly Topcon Technohouse Corporation

 Open the catalog to page 1
UV Radiometer UVR-300-2

High performance digital UV Meter. The UVR-300 is a handy-type UV radiometer with excellent efficiency and expansive ability. Three different types of high-sensitivity detectors, each for differing wavelength ranges, are available to deal with specific usages. Measuring bactericidal lamps,measurement of quantity of light of photochemical reaction,measurement of quantity of light of photoresist, and testing solarization are just a few areas where the UVR-300 stands out. Examples of use | Extra digit for detecting sensitivity 0.1 - 280,000|jW/cm2 •Correction factor (C.C.F.mode) Input correction...

 Open the catalog to page 2
UV Radiometer UVR-300-3

Detectors 3 Types of Detectors UD-250 (220 - 300nm) Three type of detectors are interchangeable and Main unit of UVR-300 is shared by three detectors. Spectral Characteristic •Spectral sensitivity characteristics UD-250 Relative sensitivity values •Spectral distribution of calibration light sources UD-250 Relative values Relative values Relative values Black lamp (FL20S•BLB) Calibrated at irradiance of 320nm to 400nm in wavelength 360 380 400 420 440 460 480 Wavelength(nm) Atandard light source A (Luminous Intensity referance lamp) Calibrated at irradiance of 360nm to 480nm in wavelength * If...

 Open the catalog to page 3
UV Radiometer UVR-300-4

Display range Detector unit types such as UD-250, UD-360A, UD-400 are available according to measurable wavelengths range, but the display unit can be used with any of them. AC adapter is used in long time continuous measurement. | Extension cable Handy for using the photoreceptor and the display unit separately. Standard optional software MT-100 can obtain measured data from UVR-300. The MT-100 operates continuous measurement up to 99,999 times. Measured data can be stored with CSV format, which can be opened by spread sheet software. *MT-100 is not included the product, it is possible to download...

 Open the catalog to page 4

All Techno Optis Co., Ltd. catalogs and technical brochures

  1. Automotive

    8  Pages

  2. AR/VR

    8  Pages

  3. SR-5100

    8  Pages

  4. UA-20

    6  Pages

  5. UA-10A

    4  Pages

  6. BM-9A

    4  Pages

  7. IM-600

    4  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.