1. Catalogs
  2. Techno Optis Co., Ltd.
  3. Spectroradiometer SR-5100

Spectroradiometer SR-5100
1 /8Pages

Spectroradiometer SR-5100

Spectroradiometer SR-5100
1 /8Pages

Catalog excerpts

Spectroradiometer SR-5100-1

5 million pixels (2448x2048) with 5 million points spectral data. High luminance 17 billion cd/m2 with built-in ND filer. 2D Spectroradiometer 2D 2 D sp spectroradiometer pectrorad diometerr ccontributes ontrib butes to o maintaining ain gh high ig gh q quality uality yo off v arious p rod ducts as iitt can evaluate th he sp pe ectral ch haracteriistics off lig ght various products the spectral characteristics light ssources ourcess o bjectss w ith h 5 million p ixels. orr o objects with pixels.

 Open the catalog to page 1
Spectroradiometer SR-5100-2

[By Non-Destruction and Non-Contact, 2D spectroradiometer instrument that contributes to [maintaining high qualityofvariousproduct^^^anevaluat^hespectnilchai^cteristics of light sources or objects with 5 million pixels. •I Non-destructivelandlnon-contact, l lmiNionlpointsloflspectral levaluationlforlthelcharacteristicslofllightlsources, fcpectral ltransmittancelcharacteristicslof materials, fendfepectral lreflectancelcharacteristicslwithlhigflaccuratel lnmlpitcflmeasurement. •l Microscopelsystemlenablesnolevaluatelspectral ldatalforlsmaNlarealwithlumlpixelleveL l(microlspectroscopy) •llmaginglspectroradiometerlwithlthelsamelperformancelaslalspotltypelspectroradiometer....

 Open the catalog to page 2
Spectroradiometer SR-5100-3

Support standard application software to measure and evaluate efficiently with easy operation. (Japanese/English) Colorimetric Image Software You can control the SR-5100 series and retrieve measured data, save data, convert measured data into image via PC. The application software conducts various types of data processing and data analyzing efficiently. •Live view Real time image that is automatically adjusted by brightness show on PC. You can check measurement area of target and adjust the position via Live-view image. •Focusing assist This function is used to adjust focus at real time. The...

 Open the catalog to page 3
Spectroradiometer SR-5100-4

Lineup and usage Standard lens Wide lens Smart Phone • Large and middle size display panel • Evaluation of luminance / chromaticity mura and spectral of the light emitting part of LED lighting and OLED lighting • Evaluation of optical characteristic of digital signage and outdoor advertising panel. • Measurement of film and glass coating mura and interference fringes • Analysis and quantification evaluation of slight differences in the staining • Skin care assessment of skin blemishes and pigmentation • Analysis of absorption, reflection and transmission characteristics • Spectral evaluation...

 Open the catalog to page 4
Spectroradiometer SR-5100-5

❖ Multi points color rendering index ❖ SR-5100HM C-mount adapter application exampleEnable to evaluate high accurate spectrum distribution with contactless by microscope lens, zoom lens and system integration. SR-5100HM + Wide angle lens

 Open the catalog to page 5
Spectroradiometer SR-5100-6

Spectral transmission factor correction tool for microscope lens. •Light source: Halogen lamp •Lamp life : Approx. 700 hours •Operating conditions : Temperature 0 to 40^ Humidity 20 to 80%R.H. (No condensation) •Dimensions : Light unit : 115x130x281 mm Diffuser unit : 109x29x62 mm Light guide length : 1 m •Power supply : ZV-57(AC 100 to 120V) ZV-58(AC 200 to 220V Spectral transmission factor correction tool for zoom lens. •Operating conditions : Temperature 0 to 40^ Humidity 20 to 80%R.H. (No condensation) •Dimensions: Light unit: 97x245x110 mm Diffuser unit : 223x212x19mm Light guide length...

 Open the catalog to page 6
Spectroradiometer SR-5100-7

System diagram SR-5100 main body AC adapter (Standard accessory) Attachment wide lens AL-5001 USB 3.0 cable (Standard accessory) Computer(*) Tripod 5N Tripod head (Standard accessory of Tripod 5N) Carrying case (Standard accessory) Colorimetric Image software CI-100 (Standard accessory) Black MURA (Optional sohtware) (*)Goods on the market Dimension SR-5100HWS Standard lens Use only specified screws when using the tripod screw and screw holes for jig attachment. Do not tighten the screws any more than necessary. Doing so might cause internal breakage

 Open the catalog to page 7
Spectroradiometer SR-5100-8

*1:Standard lens + Attachment lens, *2:Standard illuminant A, *3:Standard illuminant A, *4:Hg, Hi precision mode, *5:FWHM, Hi precision mode, *6:At the center of sensor, *7 Within 2o, *8:Max value - Min value, *9:Center of the sensor, Standard illuminant A, within 80% of field of view, Measurement area: Standard lens Hardware requirement Measurement area: Wide lens Measurement area: Telephoto lens “Microsoft and Windows are registered trademark of Microsoft Corp. in the US and other countries. “Intel Core is a registered trademark or trademark of Intel Corporation in the US and other countries....

 Open the catalog to page 8

All Techno Optis Co., Ltd. catalogs and technical brochures

  1. UA-20C,UA-20Y

    6  Pages

  2. BM-9A

    4  Pages

  3. IM-600

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.