Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids For use in large diameter pipes as an economical solution for flow measurement Flow rate measurement is independent temperature, viscosity and pressure Pulsed coil excitation to obtain a minimum zero drift No moving parts involve low maintenance, low pressure drop and allow the pass of solids Low power consumption Good chemical resistance Flow rate: 2300 l/h ... 110000 m3/h Accuracy: ±3.5% reading value Minimum electric conductivity: 20 μS/cm Connections: means of: - TF Tecfluid standard flange - 2 ¼” BSP-F - DN40 PN16 EN 1092-1 flange Materials: - Sensor: EN 1.4404 (AISI 316L), PVDF - Sensor head: PVDF - Insert pipe adaptor: EN 1.4404 (AISI 316L), PE, PVC Others on request - Electrodes: EN 1.4404 (AISI 316L), Hastelloy C, Tantalum, Titanium, Zirconium Local indication, volume totalizer, 4-20 mA and pulse outputs Alarms, empty converter model Full diagnosis for MX4 converter HART and Modbus Communication protocols available on request Modular design in two versions: - Compact converter, mounted
Open the catalog to page 1 Local indication, volume totalizer, 4-20 mA and pulse Working principle The measurement principle is based on Faraday’s induction law. A voltage V is induced between a pair of electrodes when a conductive liquid flows in a pipe of diameter D at an average velocity v, through a magnetic field B (which is perpendicular to the flow direction). This voltage, proportional to the average velocity of the liquid, is acquired by the electronic converter in order to be processed and converted to a flow rate measurement. V=B·v·D V = Voltage across the electrodes v = Liquid velocity Alarms, empty...
Open the catalog to page 2Electromagnetic flowmeters Series FLOMAT Models In case of metallic or plastic pipe where Tecfluid insert pipe adaptor can be supplied (see p. 2), installation can be made by welding or gluing the adaptor as follows: In those cases where Tecfluid insert pipe adaptor cannot be used (FRP or similar pipes), installation should be made by means of a CLAMP-ON saddle (not supplied): CLAMP-ON saddle for non-metallic pipes CLAMP-ON saddle for plastic pipes Insert pipe adaptor Sensor body EN 1.4404 (AISI 316L), Hastelloy C, Titanium, Tantalum, Zirconium * Also available in EN 1.4404 (AISI 316L) on...
Open the catalog to page 3Sensor with compact converter * minimum dimension to remove the flowmeter from the pipe Insert pipe adaptor There are two different types of insert pipe adaptors. For pipe size DN40 ... DN65, insert pipe adaptor is supplied already welded to short length of pipe that must be just coupled to the pipe by welding or gluing (in the case of PVC). For pipe size of DN80 or bigger, insert pipe adaptor is directly welded (or glued) on the pipe. Insert pipe adaptor DN s: pipe thickness (depends on pipe material and pressure rating) C: penetration depth Sensor with remote converter (IP68 10 m H2O)
Open the catalog to page 4Electromagnetic flowmeters Series FLOMAT Flow ranges Sensor selection The diagram shows the correspondance between the liquid velocity and the flow rate for different sensor sizes. The sensor size should be chosen selecting a liquid velocity of about 3-4 m/s. The minimum liquid velocity should not be below 0.5 m/s. When the liquid has solids in suspension, it is better to work between 3 and 5 m/s in order to avoid sedimentation in the pipe and sensor. 1000 Accuracy curve (error vs velocity) ± e (%) 30 v ≥ 0.4 m/s v < 0.4 m/s e = ± 3.5% reading value e = ± [1.4 / v (m/s)] % reading value...
Open the catalog to page 5Electronic converters Different models of electronic control units are available to comply with the options of flow indication, maximum / minimum flow rate control, analog and pulse outputs. All of them are compatible with the different FLOMAT-FX sensor models. Time These converters can be supplied for compact mounting directly on top of the sensor or for remote mounting. Cable is supplied. HART protocol is available for both MX4 and XT5 converters. Modbus RTU protocol is available for MX4 converter. Pulsed coil excitation XT5 converter Remote mounted converter (model XT5M) Technical data...
Open the catalog to page 6Electromagnetic flowmeters Series FLOMAT Remote mounted converter (model MX4M) MX4 converter Technical data IP67 coated aluminium enclosure Programming via front push buttons 128 x 64 graphic display Linearity: ±0.2% f.s. Repeatability: ±0.1% f.s. Ambient temperature range: -20ºC ... +60ºC Power supply: 90 … 265 VAC 50 / 60 Hz 12 … 48 VDC Power consumption: ≤ 5 VA Flow rate and liquid velocity indication: * DIN 571 screws or similar are required (depending on the installation) - No. of digits: 5 (0 to 2 decimal configuration) - Digit size: 11 mm Volume...
Open the catalog to page 7 Maintenance of FLOMAT sensors without interruption of the FLOMAT-TAP The FLOMAT-TAP accessory is a useful complement for the FLOMAT sensors in some type of installations. The key features of the product are: The M-TAP accessory must be installed to the main pipe as an insert pipe adaptor and it is a part of the complete system FLOMAT-TAP. FLOMAT sensors can be inserted or removed under pressure (pipe full of liquid). Designed for obtaining flow measurement in different points of a distribution network with only one FLOMAT sensor. 660 M-TAP insert pipe adaptor 338.5 - s 332.0 - s...
Open the catalog to page 8All TECFLUID catalogs and technical brochures
-
Series M21
6 Pages
-
SERIE FLOMID
8 Pages
-
SERIE FLOMAT
8 Pages
-
SERIE DP
8 Pages
-
Serie CU
6 Pages
-
Series COVOL
12 Pages
-
Series AD/VH
8 Pages
-
Serie 6000
8 Pages
-
Series 2000
8 Pages
-
Series 60M1
4 Pages
-
Series_LP_Level_displacer
6 Pages
-
Series_LC_Level_Switch
5 Pages
-
Series_LT_Level_gauges
8 Pages
-
Series_TM_Turbine_flowmeter
10 Pages