Overview
The document outlines the specifications and operational guidelines for the COVOL Series oscillating piston flowmeters, which are designed for measuring the flow of various liquids, including those with high viscosity. These flowmeters are applicable in industries such as chemical, petrochemical, tank filling, and fuel consumption measurement.
Specifications
  • Handles liquids with viscosity up to 120,000 mPa·s.
  • Flow rate range: 25 l/h to 60 m³/h.
  • Accuracy: ±0.8% of measured value; Repeatability: ±0.3%.
  • Materials: Body options include AISI 316L, PVC, PP, PTFE; Piston options include PTFE+graphite, aluminium, bronze, PVDF.
  • Connections: EN 1092-1 flange, BSP/NPT threaded, and sanitary couplings.
  • Temperature range varies by material, e.g., AISI 316L: -40ºC to +150ºC.
  • Pressure ratings: AISI 316L up to PN16, others up to PN10.
Working Principle
The flowmeter operates with an oscillating piston within an annular measuring chamber. The liquid flow causes the piston to oscillate, dividing the chamber into inlet and outlet sections, ensuring a constant volume of liquid is moved per cycle. A magnet within the piston activates a reed switch, providing an output signal for electronic conversion.
Installation and Maintenance
  • Can be mounted horizontally or vertically, with bidirectional flow measurement.
  • Requires a filter with a mesh size between 0.5 and 1 mm before the unit.
  • Installation of an air/steam separator is recommended for accurate measurements.
  • To prevent cavitation, follow API Std 2534 guidelines for outlet pressure.
Electronic Converters and Options
  • Various models available for flow rate indication, volume totalization, and batching applications.
  • Options include 4-20 mA analog output, HART protocol, and Exd versions for hazardous environments.
Applications
Suitable for use in chemical and petrochemical industries, tank filling, steam condensate measurement, and fuel consumption monitoring.
ATEX Compliance
The flowmeter is suitable for installation in ATEX hazardous areas with Exi intrinsically safe or Exd ExProof protection options.
Exd Housing Models
  • Model ADF30: A blind housing with reduced dimensions.
  • Model ADF60V: Housing with a window, capable of including CIP … CIP II or CP ... CH420L converters.
  • Model ADF60: Similar to ADF60V but with a blind housing.
Technical Data
  • Ambient temperature range: -20ºC to +60ºC.
  • Electrical wiring is contained within the Exd housing.
  • ATEX packing glands available for standard or shielded cables upon request.
  • Associated electronics include:
    • CIP ... CIP II: Battery-powered totalizer.
    • CP … CH420: 2-wire system transmitter with flow rate indication, volume totalizer, and 4-20 mA output. HART protocol is optional.
  • ATEX certificate: Ex d IIC T6 Gb / Ex tb IIIC T85ºC Db.
Dimensions
The document provides a table of dimensions for different DN sizes and materials (AISI 316L and PP/PVC/PTFE). Exd housings are not available for flowmeter sizes DN10 (H) and DN100 on request.
Company Information
Tecfluid S.A. is located in Barcelona and has a presence in over 50 countries worldwide. The company is ISO 9001 certified and complies with the Pressure Equipment Directive 97/23/CE and ATEX European Directive 94/9/CE.
Trademarks
HART® is a registered trademark of the HART Communication Foundation. VITON® is a registered trademark of DuPont Dow Elastomers. TRI-CLAMP® is a registered trademark of Alfa Laval Inc.
See more

Catalog excerpts

Series COVOL-1

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids            Suitable for all kind of liquids Viscosity up to 120000 mPa·s Excellent performance with changing process conditions Easily cleaned and sterilized Available with materials and connections suitable for hygienic applications Bidirectional flow measurement and installation in all flow directions Special design for high pressure available Flow rate: 25 l/h ... 60 m3/h Accuracy: ±0.8% measured value Repeatability: ±0.3% Connections: - EN 1092-1 flange DN10 ... DN100 Other flange standards on request - Threaded connections BSP or NPT - Sanitary couplings according to ISO 2852, SMS 1145, DIN 11851, TRI-CLAMP® Materials: - Body: EN 1.4404 (AISI 316L), PVC, PP, PTFE - Piston: PTFE+graphite, aluminium, bronze, PVDF - Gaskets: NBR / PTFE / EPDM / Viton® / Silicone Potential free reed switch output Optional: - Flow indication, local or remote - Volume totalizer, local or remote - Electronic transmitter with 4-20 mA analog output. HART protocol available on request - V

 Open the catalog to page 1
Series COVOL-2

Working principle By means of oscillating piston and an annular measuring chamber.  Chemical and petrochemical industry  Tank filling and batching applications  Measurement of steam condensates in boilers 1– The first figure shows the COVOL flowmeter at the beginning of a cycle, when the measuring chamber (in blue) is completely full.  Burners, measurement of fuel consumption Technical data  Accuracy: ±0.8% measured value  Repeatability: ±0.3% 2– The flow of the liquid through the flowmeter makes a force on the oscillating piston, so that it starts turning. From this moment the measuring...

 Open the catalog to page 2
Series COVOL-3

Mounting Both in horizontal and vertical position, bidirectional flow measurement and suitable for all flow directions. Straight pipe run before and after the flowmeter is not required. In order to assure the good performance of a COVOL flowmeter, the installation of a filter prior to the unit is mandatory, with a mesh size between 0.5 and 1 mm, according to the pipe diameter (smaller sizes involve a smaller mesh size). In those processes where air or gases, liquid evaporation, etc. might be present, an air/steam separator must be installed before the flowmeter, in order to obtain a real volume...

 Open the catalog to page 3
Series COVOL-4

Available for DN100 with special design. Please consult factory COVOL-H DN10 / ¼” low flow, horizontal

 Open the catalog to page 4
Series COVOL-5

Threaded connection BSP/NPT Oscillating piston flowmeters Series COVOL Sanitary couplings * Other sizes on request All dimensions In mm * OD: pipe 0ext according to ISO 2037 Other standards on request (DIN 32676,TRI-CLAMP®,...)

 Open the catalog to page 5
Series COVOL-6

Flow scales Max . i ntermittent pulses / litre l/h water l/h water approx. The COVOL flowmeters are calibrated with water (density 1 kg/l and viscosity 1 mPa-s). After this calibration the pulse / litre factor is obtained. With this factor, the associated electronic converter can make the calculation of the flow rate and/or the volume values. As shown in the accuracy curve, the area where the maximum accuracy is obtained is by the mid of the flowmeter flow range. The measurement errors can be corrected in the different associated electronic converters by means of the adjustment of the...

 Open the catalog to page 6
Series COVOL-7

Oscillating piston flowmeters Series COVOL ΔP increase (mmH 2O) due to the effect of density and viscosity Graph 2 3 2.7 ν (cSt) = Electronic converters Model CP ... CH420  4-20 mA transmitter  System: - Compact (CP ... CH420L) - Remote in DIN rail (CP ... CH420R) - Remote in panel (CP … CH420P)  Electronics mounted in a housing with aluminium base and polycarbonate (UV resistant) cover (CP … CH420L)  Power supply: - 2-wire, loop powered - Nominal voltage: 8 ... 36 VDC - Power consumption: ≤20 mA  Totalizer: - Nº of digits: 7 - Size of digit: 8 mm - Reset: by means of keyboard  Flow...

 Open the catalog to page 7
Series COVOL-8

Model CIP … CIP II  Volume totalizer: - Model CIP: resettable totalizer - Model CIP II: non-resettable totalizer and resettable partial totalizer  Compact or remote system  Electronics mounted in a housing with aluminium base and polycarbonate (UV resistant) cover  Battery powered (CR-2450): - Nominal voltage: 3 V - Load: 560 mAh - Power consumption: 8 μA  Totalizer: - Nº of digits: 7 - Size of digit: 8 mm - Reset: by means of key or magnet (non-resettable for CIP II)  Partial totalizer (only available for CIP II): - Nº of digits: 5 - Size of digit: 5 mm - Reset: by means of key or...

 Open the catalog to page 8
Series COVOL-9

Oscillating piston flowmeters Series COVOL Model MC01  Electronic converter for flow rate indication, volume totalizer,  Electronic converter for volume preselection and totalization partial volume totalizer and preselector with relay output for batching  Fully programmable by the user  Panel mounted  Power supply: 24, 110, 220, 240 VAC 50 / 60 Hz 12, 24 VDC  2-line LCD display with 16 characters (5 mm height)  7 digits totalizer, partial totalizer and volume preselector  Relay output for batching  Flow rate indicator in l/h y m3/h  Dimensions 96 x 96 mm DIN 43700  Ingress...

 Open the catalog to page 9
Series COVOL-10

ATEX version The COVOL flowmeter is suitable for its installation in ATEX hazardous area, that is, in those zones where a potentially explosive atmosphere can be generated. There are two types of protection available: Exi intrinsically safe or Exd ExProof. Exia protection The reed sensor is considered as “simple apparatus” according to EN 60079-11 standard clause 5.7, since it does not contain its own source of ignition. Reed sensor technical data: - Vmax.: 30 V ; Imax.: 20 mA - Maximum switched power: 0.6 VA - Max. ambient temperature: 40°C According to these data, the flowmeter can be installed...

 Open the catalog to page 10
Series COVOL-11

DN AISI 316L PP/PVC/PTFE AISI 316L PP/PVC/PTFE 15 205 220 250 265 Exd housings are not available for flowmeter sizes DN10 (H) and DN10 DN100 on request

 Open the catalog to page 11
Series COVOL-12

R-CT-COVOL Rev. 1 english version PRESENCE IN MORE THAN 50 COUNTRIES ALL OVER THE WORLD Tecfluid S.A. Narcís Monturiol 33 08960 Sant Just Desvern Barcelona Tel: +34 93 372 45 11 Fax: +34 93 473 44 49 [email protected] www.tecfluid.com Quality Management System ISO 9001 certified by Pressure Equipment Directive 97/23/CE certified by ATEX European Directive 94/9/CE certified by HART® is a registered trademark of HART Communication Foundation The technical data described in this specification sheet is subject to modification without notification if the technical innovations in the manufacturing...

 Open the catalog to page 12

All TECFLUID catalogs and technical brochures

  1. Series M21

    6  Pages

  2. SERIE FLOMID

    8  Pages

  3. SERIE FLOMAT

    8  Pages

  4. SERIE DP

    8  Pages

  5. Serie CU

    6  Pages

  6. Series AD/VH

    8  Pages

  7. Serie 6000

    8  Pages

  8. Series 2000

    8  Pages

  9. Series 60M1

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.