Overview
The document provides detailed specifications and operational guidelines for the Series 6000 glass tube flowmeters, designed for measuring the flow of liquids and gases. These flowmeters are characterized by easy installation, local indication through direct reading, and low pressure drop. They are available with scales in various units such as l/h, m3/h, kg/h, and more.

Specifications
- Flow Rate: Water: 2.5 l/h to 50 m3/h; Air: 45 Nl/h to 1500 Nm3/h
- Accuracy: 1.6% (qG=50%)
- Connections: BSP or NPT threaded (½” to 3”), EN 1092-1 or ANSI flanges (DN15 to DN80), sanitary couplings (ISO 2852, SMS 1145, DIN 11851, TRI-CLAMP®)
- Materials: Measuring tube made of borosilicate glass; frame of galvanized and coated steel; protection shield of metacrylate; wetted parts available in various materials including EN 1.4404 (AISI 316L), PVC, PP, PTFE, PVDF

Technical Data
- Fluid Temperature: -20ºC to +80ºC
- Ambient Temperature: -20ºC to +60ºC
- Working Pressure: 5 to 15 bar max, depending on flowmeter size
- Measuring Tube Length: 300 mm
- Operation: Vertical with upwards flow

Options
- Limit switches (1 or 2 adjustable)
- Electronic transmitter with 4-20 mA analog output, suitable for safe or hazardous areas (ATEX certified)

Applications
- Water treatment, heating-cooling circuits, laboratories, control of gas burners, chemical industry, and treatment ovens

Models
- Various models available with different connection types and materials, including 6001 (BSP threaded), 6002 (EN 1092-1 flange), 6009 (PVC solvent socket), 6011 (DIN 11851 sanitary coupling), and more.

Working Principle
The flowmeters operate on the variable area principle, where a float moves inside a tapered glass tube. The fluid flow forces the float to a position where the free area allows the flow to pass, balancing the forces of fluid flow, float weight, and free area.

Limit Switches and Transmitters
- Various types of limit switches and transmitters are available, including adjustable micro-switches, inductive switches, reed switches, and infrared optical switches. These are suitable for different flow ranges and environmental conditions.

Materials and Dimensions
- Detailed material specifications and dimensions are provided for different models and components, ensuring compatibility with various industrial standards and applications.

Additional Information
- The document includes graphs for changes in density and viscosity, flow rate equivalent curves, and detailed technical data for transmitters and limit switches. It also mentions compliance with various certifications and standards, including ISO 9001, Pressure Equipment Directive 97/23/CE, and ATEX European Directive 94/9/CE.
See more

Catalog excerpts

Series_6000_Glass_tube_flowmeters-1

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases       Easy installation Local indication by means of direct reading Low pressure drop Scales directly in l/h, m3/h, kg/h, l/min, %, etc. Plastic protection against accidental breakage of the glass tube Flow rate: - Water: 2.5 l/h ... 50 m3/h - Air: 45 Nl/h ... 1500 Nm3/h Accuracy: 1.6% (qG=50%) Connections: - BSP or NPT threaded connections: ½” ... 3” - EN 1092-1 or ANSI flanges: DN15 ... DN80 Other flange standards on request - Sanitary couplings according to ISO 2852, SMS 1145, DIN 11851, TRI-CLAMP® Materials: - Measuring tube: borosilicate glass - Frame: galvanized and coated steel, EN 1.4301 (AISI 304) - Protection shield: metacrylate - Wetted parts: galvanized and coated steel, EN 1.4404 (AISI 316L), PVC, PP, PTFE, PVDF - Float: EN 1.4404 (SS 316L), PVC, PP, PTFE, PVDF Local indication Options: - 1 or 2 limit switches - Electronic transmitter with 4-20 mA analog output for safe or hazardous area (Ex ia IIC T6 protection, ATEX certified). HART, FIE

 Open the catalog to page 1
Series_6000_Glass_tube_flowmeters-2

 6000-PVC wetted parts in PVC. Other components in Working principle The 6000 series flowmeters work according to variable area principle, which is obtained by a float that moves inside a borosilicate glass tapered tube. The fluid flows up through the tapered tube forcing the float to a position with sufficient free area to enable the flow to pass, where there is an equilibrium of forces: - E = force of the fluid flow galvanized and coated steel wetted parts in PP. Other components in galvanized and coated steel  6000-PTFE wetted parts in PTFE. Other components in galvanized and coated steel...

 Open the catalog to page 2
Series_6000_Glass_tube_flowmeters-3

Glass tube flowmeters Series 6000 Materials Flowmeters with guided float Frame gasket Measuring tube Springs / Stops Connector gasket Borosilicate glass AISI 316L / Aluminium / PVDF-Pb / PVC-Pb / Flange seat Centering ring In all cases, galvanized and coated steel - Other gasket materials on request: VITON®, EPDM * Only the most usual are shown. Float material might change depending on application requirements. ** For low flows.

 Open the catalog to page 3
Series_6000_Glass_tube_flowmeters-4

Models 6001 (BSP / NPT) - 6009 (socket / welding)

 Open the catalog to page 4
Series_6000_Glass_tube_flowmeters-5

Glass tube flowmeters Series 6000 Flow ranges Flow scales Flow scales Aluminium float 2.85 g/cm³ Glass float 2.60 g/cm³

 Open the catalog to page 5
Series_6000_Glass_tube_flowmeters-6

Flow rate equivalent curves water-liquids (with different density and viscosity) Flow rate Flow rate Change in viscosity (graph 1) Change in density (graph 2) Viscosity (mPa·s) for density 1 kg/l Nº 1. Changes in density (graph 2) If the point lies between two curves, it is optional to select: Required flow rate 1000 I/h, density 1.4 kg/I. Enter the graph at the 1000 I/h point. Move horizontally across to applicable flow tube line (C313-1000), travel the inclined line to the point of the density of the fluid (1.4 kg/I). Travel horizontally to the vertical axis and read the equivalent flow scale...

 Open the catalog to page 6
Series_6000_Glass_tube_flowmeters-7

Glass tube flowmeters Series 6000 Limit switches Adjustable limit switch PT-AMR Adjustable limit switch 60-AMM (Flow rate from 10-100 l/h water and equivalent air ranges. AISI 304 frame is required for flow ranges 10-100, 16-160 and 25-250 l/h water and equivalent air ranges) (Flow rate from 40-400 l/h water and equivalent air ranges) Bi-stable SPST reed switch, actuated by a magnet inside the float and mounted in a PVC enclosure.  60-AMM1 … 2: 1 … 2 adjustable limit switches  PT-AMR1 ... 2: 1 ... 2 adjustable limit switches  Contact rating: 0.5 A / 250 V / 12 VA  Hysteresis: ±5% of full...

 Open the catalog to page 7
Series_6000_Glass_tube_flowmeters-8

Adjustable limit switch 60-AMO (Flow rate up to 25-250 l/h water and equivalent air ranges) Infrared optical switch, actuated by the float when crossing the beam, mounted in a plastic enclosure and supplied together with control relay in an aluminium housing. Suitable for all float materials except glass.  60-AMO1 ... 2: 1 ... 2 adjustable limit switches  Contact rating: 1A 220 VAC / 50Hz  Hysteresis: ±5% of full scale value  Ambient temperature: -10ºC ... +80ºC  Power supply: 220 VAC / 50Hz or 24 VDC - 8 ... 35 VDC, safe area version (Flow rate from 40-400 l/h water equivalent air...

 Open the catalog to page 8

All TECFLUID catalogs and technical brochures

  1. Series M21

    6  Pages

  2. SERIE FLOMID

    8  Pages

  3. SERIE FLOMAT

    8  Pages

  4. SERIE DP

    8  Pages

  5. Serie CU

    6  Pages

  6. Series COVOL

    12  Pages

  7. Series AD/VH

    8  Pages

  8. Serie 6000

    8  Pages

  9. Series 2000

    8  Pages

  10. Series 60M1

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.