Serie 6000
8Pages

{{requestButtons}}

Catalog excerpts

Serie 6000 - 1

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases       Easy installation Local indication by means of direct reading Low pressure drop Scales directly in l/h, m3/h, kg/h, l/min, %, etc. Plastic protection against accidental breakage of the glass tube Flow rate: - Water: 2.5 l/h ... 50 m3/h - Air: 45 Nl/h ... 1500 Nm3/h Accuracy: 1.6% (qG=50%) Connections: - BSP or NPT threaded connections: ½” ... 3” - EN 1092-1 or ASME B16.5 flanges: DN15 ... DN80 / ½” … 3” Other flange standards on request - PVC solvent weld socket connections or EN 1.4404 (AISI 316L) connections for welding - Sanitary couplings according to ISO 2852, SMS 1145, DIN 11851, TRI-CLAMP® Materials: - Measuring tube: borosilicate glass - Frame: galvanized and coated steel, EN 1.4301 (AISI 304) - Protection shield: polycarbonate (UV resistant) - Wetted parts: galvanized and coated steel, EN 1.4404 (AISI 316L), PVC, PP, PTFE, PVDF - Float: EN 1.4404 (SS 316L), aluminium, PVC, PP, PTFE, PVDF Local indication Options: - 1 or 2 limit switches - Electronic transmitter with 4-20 mA analog output for safe or hazardous area (Ex ia IIC T6 protection, ATEX certi

Open the catalog to page 1
Serie 6000 - 2

 6000-PVC wetted parts in PVC. Other components in Working principle The 6000 series flowmeters work according to variable area principle, which is obtained by a float that moves inside a borosilicate glass tapered tube. The fluid flows up through the tapered tube forcing the float to a position with sufficient free area to enable the flow to pass, where there is an equilibrium of forces: - E = force of the fluid flow galvanized and coated steel wetted parts in PP. Other components in galvanized and coated steel  6000-PTFE wetted parts in PTFE. Other components in galvanized and coated steel ...

Open the catalog to page 2
Serie 6000 - 3

PTFE+NBR, NBR, VITON®, EPDM 4 Frame gasket NBR, VITON®, EPDM Borosilicate glass EN 1.4404 / Aluminium / PVDF-Pb / PVC-Pb / PP -Pb PTFE-Pb, PVDF-Pb PTFE PTFE+NBR, NBR, VITON®, EPDM Steel PTFE PTFE 13 Centering ring 14 Washer 15 Guide PTFE PTFE PTFE In all cases, galvanized and coated steel EN 1.4404 = AISI 316L ; EN 1.4401 = AISI 316 ; EN 1.4301 = AISI 304 ; EN 1.4310 = AISI 302 ' Only the most usual are shown. Float material might change depending on application requirements '* For low flows

Open the catalog to page 3
Serie 6000 - 4

Dimensions Model 6001 (BSP / NPT) (socket / welding) Weight R” / NPT DN A HR L Model 6002 (EN 1092-1) Weight DN D k g b l x n° L Model 6002 (ASME B16.5 150#) Weight NPS D k g b l x n° L kg M1 y2” 88.9 60.3 34.9 11.1 15.9x4 380 2.5

Open the catalog to page 4
Serie 6000 - 5

Flow ranges Model N° Flow scales EN 1.4404 float 7.95 g/cm3 Fl ow scales Aluminium float 2.85 g/cm3

Open the catalog to page 5
Serie 6000 - 6

Viscosity (mPa-s) for density 1 kg/l Density (kg/l) Examples of calculation N° 1. Changes in density (graph 2) Flow rate to be measured: 1000 l/h Liquid density: 1.4 kg/l Enter the graph at the 1000 l/h point and move horizontally to the left until the thick line that determines the proper flow tube (C33-10001). Follow the inclined line until crossing the 1.4 kg/l vertical line. From this point, move horizontally to the right until reaching the flow scale axis, where we can determine that the maximum flow rate we can measure with this tube is 800 l/h. N° 2. Changes in viscosity (graph...

Open the catalog to page 6
Serie 6000 - 7

Adjustable limit switch PT-AMR (Flow rate from 10-100 l/h water and equivalent air ranges. EN 1.4301 (AISI 304) frame is required for flow ranges 10-100, 16-160 and 25-250 l/h water and equivalent air ranges) Bi-stable SPST reed switch, actuated by a magnet inside the float and mounted in a PVC enclosure. • PT-AMR1 ... 2: 1 ... 2 adjustable limit switches • Contact rating: 0.5 A / 250 V / 12 VA • Hysteresis: ±5% of full scale value • Ambient temperature: -25°C ... +80°C • DIN 43650-A connector, PG9 cable gland • Suitable for ATEX hazardous area “Simple apparatus” Adjustable limit switch...

Open the catalog to page 7
Serie 6000 - 8

 TR2420Ex ATEX Ex ia IIC T6 certified version - Power supply: 8 … 30 VDC  TR2420H (HART protocol), TR2420P (Profibus protocol) (Flow rate from 40-400 l/h water and equivalent air ranges) The TMUR resistive sensor consists of a reed chain which is mounted inside a plastic enclosure IP65 rated. Installation on the flowmeter frame by means of two screws or SS straps. By means of a transmitter, the resistance signal is converted into current 4-20 mA. or TR2420F (Fieldbus protocol). Also available in combination with their Ex versions Technical data TMUR  2-wire system with 4-20 mA output ...

Open the catalog to page 8