Catalog excerpts
catalog 2011 working on.qxp 6/28/2011 2:22 PM Page 110 Liquid Chillers 730-2700 BTU/hr Teca Liquid Chillers are compact and reliable alternatives to conventional recirculating coolers. A complete integrated package is now offered in a standard configuration. FEATURES • Precise temperature control • External plumbing lines with quick connectors • 12’ of tubing and insulation included • Self priming pumps Options Available • Heating • RS-232 interface • RS-485 interface • Computer Communications software • Ramping and soaking APPLICATIONS Teca Liquid Chillers are ideal for bench-top or portable applications such as laboratory, laser, x-ray, outpatient and medical therapy as well as many others. TEAM TECA CUSTOM ENGINEERING Call us at 888-TECA-USA. We’re here to help! 110 TECA 1-888-TECA-USA (832-2872) www.teca-usa.com
Open the catalog to page 1catalog 2011 working on.qxp 6/28/2011 2:23 PM Page 111 LIQUID CHILLERS Air Cooled 730-2700 BTH/hr TLC-SERIES TLC-1400 page 112 TLC-700 page 118 1400-1450 BTU/hr Rating, 12" x 14" footprint 120 or 240 VAC operation 730-800 BTU/hr Rating, 12" x 7" footprint 120 VAC or 24 VDC operation TLC-1200 page 116 TLC-702 page 118 830-950 BTU/hr Rating, 15.4" x 7.6" footprint 24 VDC input 730-800 BTU/hr Rating, 12" x 7" footprint 240 VAC operation TLC-900 page 114 TLC³ page 124 1050-1350 BTU/hr Rating, 15.4" x 7.6" footprint 100-240 VAC or24 VDC operation 330-1250 BTU/hr Rating, various size and voltages...
Open the catalog to page 2catalog 2011 working on.qxp 12/7/2011 7:55 AM Page 112 TLC-1400 Liquid Chiller Air Cooled 120 VAC, 240 VAC Input FEATURES • Compact (only 12" X 14" bench top footprint) • Weighs approximately 59 lbs. (27 kg) • Integral PID "tunable" temperature control (two styles) • Ambient temperature up to +50°C • No compressor, fluorocarbons or filters • Virtually maintenance-free operation • Remote Sensibility™ • Un-cooled, 500mL reservoir • Front to back air-flow system • Stainless steel exterior housing • Low fluid level and low flow warning • Integral power supply • Self priming pump/reservoir • Low...
Open the catalog to page 3catalog 2011 working on.qxp 12/7/2011 7:55 AM Page 113 Liquid Chiller - Air Cooled TLC-1400 PERFORMANCE CURVE ENVIRONMENTS Bench top Laboratory Industrial COOLING CAPACITY 410 Watts @ 0 °C ⌬T (standard) DIMENSIONS Equation of line: y=⌬T(°C) x=Capacity (Watts) Ambient Temp 25°C 50°C Fluid Supply y=.08x-33.1 y=.08x-36.1 PUMP CURVE Ambient Air Path www.teca-eu.com 1-888-TECA-USA (832-2872) TECA 113
Open the catalog to page 4catalog 2011 working on.qxp 6/28/2011 2:24 PM Page 114 TLC-900 Liquid Chiller Air Cooled Bench Top 100-240 VAC and 24 VDC Input STANDARD FEATURES • • • • • • • • • • • • 90-265 VAC universal integrated power supply Heats and cools 1 Liter un-cooled reservoir Low pressure drop 3/8 I.D. fluid quick connects Variable fan speed for quieter operation User-friendly front-fill design Easy prime/pump reset feature Wide process fluid temperature range Multiport bottom to top air-flow for easier bench use Hardwired over-temperature protection No compressor, fluorocarbons or filters Virtually...
Open the catalog to page 5catalog 2011 working on.qxp 7/25/2011 9:13 AM Page 115 Liquid Chiller - Air Cooled TLC-900 PERFORMANCE CURVE Curves below represent performance of TLC-900 with pump option 1. Performance curves for systems with other pumps will be different. ENVIRONMENTS Bench top Laboratory Industrial COOLING CAPACITY 310 Watts @ 0 °C ⌬T (standard) 360 Watts @ 0 °C ⌬T (high capacity) DIMENSIONS Equation of line: y=⌬T(°C) x=Capacity (Watts) Ambient Temp 25°C 50°C Standard y=.102x-30.3 y=.102x-31.2 High Capacity y=.105x-36.2 y=.105x-38.7 PUMP CURVE Ambient Air Path www.teca-eu.com 1-888-TECA-USA (832-2872)...
Open the catalog to page 6catalog 2011 working on.qxp 6/28/2011 2:24 PM Page 116 TLC-1200 Air Cooled Liquid Chiller Air Cooled General Purpose 24 VDC input FEATURES • Two separate fluid cooling circuits • Weighs only 20 lbs. (9.1 kg) • Mount through bench top or enlcosure wall • No compressor, fluorocarbons or filters • Virtually maintenance-free operation • Stainless steel exterior housing • Mounts in any orientation • 3/8” OD Stainless steel tubing INCLUDES • Internal H-Bridge for reverse polarity operation on HC versions • Rubber feet • Power input leads SPECIFICATIONS MODEL PART NUMBER TLC-1200 6-3095-0-000...
Open the catalog to page 7catalog 2011 working on.qxp 7/10/2012 9:49 AM Page 117 Liquid Chiller - Air Cooled TLC-1200 PERFORMANCE CURVE ENVIRONMENTS Bench top OEM Industrial COOLING CAPACITY Standard: 162 Watts @ 0 °C ⌬T (25 °C Ambient) High Cap: 190 Watts @ 0 °C ⌬T (25 °C Ambient) DIMENSIONS Equation of line: y=⌬T(°C) x=Capacity (Watts) Capacity Standard High Fluid Supply y=.138x-22.4 y=.138x-26.2 FLOW CHARACTERISTICS Ambient Air Path www.teca-eu.com 1-888-TECA-USA (832-2872) TECA 117
Open the catalog to page 8catalog 2011 working on.qxp 12/7/2011 10:24 AM Page 118 TLC-700 Air Cooled Liquid Chiller Air Cooled 120 VAC, 240 VAC and 24 VDC Input FEATURES • Compact (only 15.5" X 7.6" bench top footprint) • Easy prime pump design • Integral PID "tunable" temperature control (two styles) • No compressor, fluorocarbons or filters • Un-cooled, 500mL reservoir • Front to back air-flow system • Stainless steel exterior housing • Ergonomic sloping front design • Low fluid level and low flow warning • Integral power supply • Self priming pump/reservoir • Low pressure drop fluid quick connects • Cool and...
Open the catalog to page 9catalog 2011 working on.qxp 12/7/2011 10:25 AM Page 119 Liquid Chiller - Air Cooled TLC-700 PERFORMANCE CURVE ENVIRONMENTS Bench top Laboratory Industrial COOLING CAPACITY 215 Watts @ 0 °C ⌬T DIMENSIONS Equation of line: y=⌬T(°C) x=Capacity (Watts) Ambient Temp 25°C 50°C Fluid Supply y=.14x-30.2 y=.14x-33.2 PUMP CURVE Ambient Air Path www.teca-eu.com 1-888-TECA-USA (832-2872) TECA 119
Open the catalog to page 10All TECA (ThermoElectric Cooling America) catalogs and technical brochures
-
Thermoelectric produtcs
152 Pages
-
AHP-301CP Cold plate
2 Pages
-
AHP-1200CP Cold Plate
2 Pages
-
CPV Cascades
1 Pages
-
AHP-800MSP
2 Pages
-
Cold plates
30 Pages
-
Air conditioners 90-1800 BTU/hr
142 Pages