Cold plates

Cold plates
1 / 30 PagesView full catalog

Cold plates

Product catalog summary
Overview: The document details specifications and features of cold plate models for laboratory use, focusing on air-cooled and liquid-cooled systems. These systems provide precise temperature control, offering both cooling and heating capabilities.
Air Cooled AHP-CPV Series:
  • Features include cooling to -25°C, optional heating, and temperature control.
  • Designed for low maintenance with no compressors or filters, making them compact and durable.
  • Models like AHP-1200CPV and AHP-301CPV offer cooling capacities from 225 to 950 BTU/hr, with universal input voltage (100-240 VAC).
  • Control features include integral PID temperature control, RS-232 communication, and multi-segment ramp and soak programming.
Liquid Cooled LHP-Series:
  • Models such as LHP-1700CP and LHP-1200CP provide cooling capacities from 130 to 1630 BTU/hr.
  • Operate on 24 VDC or 120/240 VAC, suitable for industrial and OEM applications.
Standard Features:
  • Integral front panel temperature control, bench top design, and external RTD sensor capability.
  • RS-232 communication with EzLog programming and logging, auto-tuning for optimal control.
  • Heating capabilities up to 90°C and cooling down to -15°C, with cascade accessories available for lower temperatures.
Applications:
  • Used in laboratory and industrial environments for specimen testing, quality control, and temperature-sensitive studies.
  • Specific applications include behavior studies, temperature range studies, and specimen storage.
Additional Features:
  • Models like AHP-800MSP include magnetic stirring capabilities with variable speed settings.
  • Optional accessories and custom modifications are available to fit specific requirements.
Performance and Control:
  • Performance curves and specifications are provided for each model, detailing cooling capacities and operational parameters.
  • Control features include smart PID control tuning, remote sensibility, and RS-232 communications for data acquisition.
Specifications and Features:
  • AHP-1200CAS with CCP-31 3 Stage Cascade: Includes features from the AHP-1200CPV series, installation tap patterns, and a clear acrylic hinged cover.
  • Performance Specifications: Lists models such as CCP-22, CCP-21, and CCP-31, detailing maximum temperature differentials, dimensions, voltage, current, and operating temperature ranges.
  • Accessories: Includes air deflectors, covers, barriers, and insulation options.
  • Cold Plates: Models such as AHP-1200CP, AHP-301CP, and AHP-300CP are described with their cooling capacities, voltage, current, and weight.
  • Liquid Cooled Cold Plates: Models like LHP-1700CP and LHP-1200CP require a constant supply of cooling fluid and offer direct contact cooling significantly below liquid temperature.
Performance Curves and Environments: Includes performance curves for different ambient temperatures and environments, indicating cooling capacities and temperature differentials for various models.
Key Features: Key features include the absence of compressors or filters, the ability to mount in any orientation, and virtually maintenance-free operation.
Specifications: Outlines specifications for various heat/cool models, including LHP-150CPHC and LHP-800CP, with key parameters like temperature range, voltage requirement, and cooling capacity.
Heating Methods: Two heating methods are mentioned: reverse polarity to thermoelectrics and embedded resistive heaters in the cold plate.
Additional Features: Products include compression fittings, auxiliary mounting holes, and machined cold plate surfaces.
Performance Curves: Provided for different models with equations indicating the relationship between temperature and capacity at fluid temperatures of 20°C, 40°C, and 60°C.
Cooling Capacity: Cooling capacities are specified for models like LHP-800CP, LHP-300CP, and LHP-150CP at 0°C ΔT.
Notes: There is an option for temperature control, and users are advised to consult the factory for more details.
See more

Catalog excerpts

Cold plates-1

catalog 2011 working on.qxp 6/28/2011 2:12 PM Page 80 Cold Plates 140-1630 BTU/hr AIR COOLED AHP-CPV SERIES LABORATORY USE STANDARD • Integral front panel temperature control • Auto tuning for best control • Bench top design • Heating to 90 °C • Universal input 100-240 VAC • Cooling to -15 °C • External RTD sensor capable • Cascade accessory to -40 °C and lower • RS-232 Comms with EzLog programming and logging • Many standard and custom accessories • Multi step ramp & soak AIR COOLED • Internal RTD standard AHP-CP SERIES GENRAL PURPOSE FEATURES • VAC & VDC versions • Remote temperature control versions • Industrial & OEM use • Sturdy, durable construction • Cooling to -15/-20 °C • Modification and custom units to fit your requirements • Strong mounting on or through bench/wall • Optional heating LIQUID COOLED FEATURES LHP-SERIES • No load cooling to -25°C (25°C Fluid) • Compact • Optional heating • Lightweight • Temperature control, optional • Durable • Low maintenance • Reliable • No compressor, fluorocarbons or filters TEAM TECA CUSTOM ENGINEERING Call us at 888-TECA-USA. We’re here to help! 80 TECA 1-888-TECA-USA (832-2872) www.teca-usa.com

 Open the catalog to page 1
Cold plates-2

catalog 2011 working on.qxp 6/28/2011 2:15 PM Page 81 COLD PLATES Air Cooled Liquid Cooled AIR COOLED CPV AHP-1200CPV page 82 AHP-1200DCP page 84 830-950 BTU/hr rating, 15" x 11.3" x 6.5” size, 5.38” X 13” cold plate surface, 100-240 VAC Dual temperature zone cold/hot plates 18.5” X 15.1” X 6.5” size (2) 13.3” X 6.3” plate surface 100-240 VAC AHP-301CPV page 86 AHP-800MSP page 88 225-265 BTU/hr rating, 10" x 9.8" x 6” size, 4.5” x 6” cold plate surface, 100-240 VAC Variable stirring rate, 19" x 9.3" x 10” size, 1 Liter standard bottle, 100-240 VAC AIR COOLED CP AHP-1200CP page 96 AHP-300CP page...

 Open the catalog to page 2
Cold plates-3

catalog 2011 working on.qxp 6/28/2011 2:15 PM Page 82 AHP-1200CPV Versatile Cold/Hot Plate Air Cooled Bench Top 100-240 VAC Input FEATURES • Precision machined cold plate surface • Easy clean stainless steel top surface • Cools and heats (TYP. -20 °C to 90 °C) • 100-240 VAC universal input • Low-profile design with ergonomic sloped front • Variable fan speed for quieter operation • Weighs only 25 lbs. (11.4 kg) • Compact bench top unit, 11.2” X 15.1” footprint • Virtually maintenance-free operation • Painted Enameled stainless steel exterior housing • Accessories for glassware (beaker/test tube)...

 Open the catalog to page 3
Cold plates-4

catalog 2011 working on.qxp 6/28/2011 2:15 PM Page 83 Versatile Cold Plate - Air Cooled AHP-1200CPV PERFORMANCE CURVE ENVIRONMENTS Bench top Laboratory Industrial COOLING CAPACITY 200 - 230 Watts @ 0 °C ⌬T Equation of line: y=⌬T(°C) x=Capacity (Watts) Ambient Temp 25°C 50°C Standard y=.195x-39.1 y=.195x-41.8 High capacity y=.185x-44.9 y=.185x-48.8 Ambient Air Path DIMENSIONS www.teca-eu.com 1-888-TECA-USA (832-2872) TECA 83

 Open the catalog to page 4
Cold plates-5

catalog 2011 working on.qxp 6/28/2011 2:15 PM Page 84 AHP-1200DCP Dual Temperature Zone Plate Air Cooled Bench Top 100-240 VAC Input FEATURES • Cools and heats two plates independently • 100-240 VAC universal input • Low-profile design with ergonomic sloped front • Variable speed fans for quiet operation • Compact bench top unit, 18.5” X 15.1” footprint • No compressor, fluorocarbons or filters. • Virtually maintenance-free operation • Painted Enameled stainless steel exterior housing • Rubber feet • Two precision machined cold plate surfaces, each 13.3” X 6.3” • Large 13.5" x 12.6" overall plate...

 Open the catalog to page 5
Cold plates-6

catalog 2011 working on.qxp 6/28/2011 2:15 PM Page 85 Dual Cold Plate - Air Cooled AHP-1200DCP PERFORMANCE CURVE ENVIRONMENTS Bench top Laboratory Industrial COOLING CAPACITY (individual plate) 200 - 240 Watts @ 0 °C ⌬T COOLING CAPACITY (combined) 400 - 480 Watts @ 0 °C ⌬T Performance varies with cold plate temperature differential. Performance curve is for one cold plate at an ambient of 25 °C. Performance of one cold plate will vary with the temperature of the other cold plate. Ambient Air Path DIMENSIONS www.teca-eu.com 1-888-TECA-USA (832-2872) TECA 85

 Open the catalog to page 6
Cold plates-7

catalog 2011 working on.qxp 5/30/2012 11:18 AM Page 86 AHP-301CPV Versatile Cold/Hot Plate Air Cooled Bench Top 100-240 VAC Input FEATURES • Precision machined cold plate surface • Easy clean stainless steel top surface • Cools and heats (TYP. -20 °C to 90 °C) • 100-240 VAC universal input • Low-profile design with ergonomic sloped front • Weighs only 13 lbs. (5.9 kg) • Compact bench top unit, 9.8” X 10.1” footprint • No compressor, fluorocarbons or filters. • Virtually maintenance-free operation CONTROL FEATURES • Integral TC-4300 PID "tunable" temperature control • One shot smart PID control...

 Open the catalog to page 7
Cold plates-8

catalog 2011 working on.qxp 5/30/2012 11:18 AM Page 87 Versatile Cold Plate - Air Cooled AHP-301CPV PERFORMANCE CURVE ENVIRONMENTS Bench top Laboratory Industrial COOLING CAPACITY 82 Watts @ 0 °C ⌬T Equation of line: y=⌬T(°C) x=Capacity (Watts) Ambient Temp 25°C 50°C Cold Plate y=.51x-42.1 Ambient Air Path y=.51x-45.4 DIMENSIONS www.teca-eu.com 1-888-TECA-USA (832-2872) TECA 87

 Open the catalog to page 8
Cold plates-9

Catalog 12.1 CP.qxp 4/19/2012 2:37 PM Page 16 AHP-800MSP Magnetic Stirring Cold/Hot Plate Air Cooled Bench Top 100-240 VAC Input FEATURES • Heating and cooling • Unique high-performance side mounting cold plate for added cooling and uniform temperatures • Magnetic drive for stir bars from underneath the bottle • Magnetic stir offers 5 speed settings • Standard and custom sleeves • Made for use with Corning Pyrex® brand 1000 beakers or equivalent size beakers or bottles • 100-240 VAC universal, Integral power supply • North American Standard power input cord set • Variable speed fan for reduced...

 Open the catalog to page 9
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.