Overview: The XPLORER-NS by TE Instruments is a combustion analyzer designed for the precise measurement of Total Nitrogen and Total Sulfur in various sample types, including solids, liquids, gases, and LPGs. It offers both standardized and customizable solutions for modern laboratories, with capabilities ranging from low ppb to high ppm levels.
Key Features:
  • Compact design with the smallest footprint in the market.
  • Quick start-up time of less than 15 minutes.
  • Simultaneous analysis of Nitrogen and Sulfur.
  • Complies with international standards such as ASTM, ISO, EN, and IP.
  • Automated calibration and sample handling with optional autosamplers like ARCHIE and GLS.
  • Low maintenance with high stability and reliability due to temperature-controlled detectors.
Performance and Configuration: The XPLORER-NS supports both manual and automated sample introduction, with options for liquid, solid, gas, and LPG samples. It features a user-friendly interface through the TE Instruments Software (TEIS), which allows for efficient data management and analysis.
Compliance and Standards: The analyzer meets various international standards for Total Sulfur and Total Nitrogen, including ASTM D5453, ASTM D4629, and others. It is suitable for applications in chemical, petrochemical, and governmental laboratories.
Methodology: The XPLORER-NS uses high-temperature combustion followed by chemiluminescence and UV-fluorescence detection to measure Nitrogen and Sulfur. This method ensures accurate detection at low ppb levels.
Industrial Applications: The analyzer is applicable in industries dealing with chemicals, refinery products, and gases, providing solutions for surveyor laboratories, chemical laboratories, and research facilities.
Technical Specifications:
  • Dimensions: 36 x 27.2 x 69 cm
  • Weight: 32 kg
  • Power: 1150 W
  • Furnace temperature: up to 1150 °C
  • Sample size: Solids (5-1000 mg), Liquids (100 µL), Gas (10 mL), LPG (100 µL)
Conclusion: The XPLORER-NS is a versatile and efficient analyzer that meets the stringent requirements of modern analytical laboratories, offering high performance and compliance with international standards.
See more

Catalog excerpts

XPLORER TN/TS-1

Configuration: XPLORER with ARCHIE and GLS* // X PLORER- NS Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory. TE Instruments has developed the X PLORER-NS, standardized and customized solutions to a Total Nitrogen and Total Sulfur combustion match both current and future analytical analyzer, offering fast, accurate and precise needs, ranging from low ppb’s to high ppm’s. analysis of solids, liquids, gases and LPG’s. This brand new model is designed to offer www.TE Instruments.com

 Open the catalog to page 1
XPLORER TN/TS-2

Speed & Performance with minimal footprint Key features include: Configuration: XPLORER with ARCHIE* Compact design, smallest footprint in today’s market Short start-up time (less than 15 minutes) Fast and precise measurement of solids, liquids, gases and LPG’s Easy to use and intuitive user interface, operation software Simultaneous analysis of Nitrogen and Sulfur Fast and easy switching between modules, resulting in high productivity Complies with international standards like: ASTM, ISO, EN and IP Easy upgrades with autosamplers for solids, liquids, gases and LPG’s Fully automated creation...

 Open the catalog to page 2
XPLORER TN/TS-3

syringe driver. It offers full control over the desired volume and speed of injection. For the introduction of solid samples, there is an integrated software controlled boat drive. Both features XPLORER-NS. If the analyzer operates in full automation, the robotic XYZ auto sampler, the ARCHIE, handles all liquid samples from 105 up to 210 positions. It extracts the samples from 2 mL vials and is able to dilute samples and generate calibration standards automatically. Optional available which are adjustable in temperature for higher and low boiling sample matrices. For the introduction of gas and...

 Open the catalog to page 3
XPLORER TN/TS-4

TE Instruments Analytical Software (TEIS): Ensuring intuitive and smooth control of your analysis. The user interface of the TE Instruments Software (TEIS) hardly needs any explanation. Its simplicity ensures smooth operation of the X PLORER series, with intuitive controls and operation features. TEIS assists the user to achieve routine analyses in an efficient, fast and reliable way. Instrument operation remains simple. This resourceful software makes it possible to modify sample lists, evaluate data and calibration lines, completely independent. Results can be presented in customized print...

 Open the catalog to page 4
XPLORER TN/TS-5

How does it work? Samples are introduced, using the appropriate introduction module, into a furnace, where the oxidation combustion, nitric oxide (NO) and Sulfur dioxide (SO 2) are formed and led into the Liquids module* serial connected reaction chambers, in the meantime water and particles have been removed. COMBUSTION Sulfur detection: R-SN + O 2 Nitrogen detection: Sulfur is measured by pulsed UV-fluorescence. Sulfur dioxide (SO 2 ) is formed during the oxidation and is transferred to the reaction chamber. Here it is excited by a pulsed UV Electronically generated ozone is added which source...

 Open the catalog to page 5
XPLORER TN/TS-6

Option: GLS Autosampler The next generation Gas & LPG sampling system. TE Instruments has developed the GLS, suitable for handling all sorts of gases and LPG’s for the analysis of Total Chlorine, Nitrogen and Sulfur. The GLS combines excellent with the X PLORER combustion analyzer, but also does an excellent job as a stand-alone gas and LPG auto sampler with any other combustion auto sampler GLS* Option: A RCHIE Autosampler TE Instruments is proud to introduce our robotic liquids auto sampler, ARCHIE. Unlike previous generation liquids samplers, the ARCHIE uses a 100 µL syringe to inject the...

 Open the catalog to page 6

All TE Instruments catalogs and technical brochures

  1. XPLORER TN

    6  Pages

  2. XPREP - 3

    2  Pages

  3. ARCHIE

    2  Pages

  4. NEWTON

    6  Pages

  5. TUSCAN

    2  Pages

  6. GLS & GBS

    4  Pages

  7. XPLORER

    6  Pages

  8. XPLORER-TX/TS

    6  Pages

  9. XPLORER-NS

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.