1. Catalogs
  2. TCR Tecora
  3. ECHO EMERGENCY HV

ECHO EMERGENCY HV
1 /2Pages

ECHO EMERGENCY HV

ECHO EMERGENCY HV
1 /2Pages

Catalog excerpts

ECHO EMERGENCY HV-1

POLLUTION CHECK https://www.tcr-tecora.com/en/outdoor-air-quality/echo-emergency-hv-high-volume-sampler/ https://www.tcr-tecora.com/en/outdoor-air-quality/echo-emergency-hv-high-volume-sampler/ https://www.tcr-tecora.com/en/outdoor-air-quality/echo-emergency-hv-high-volume-sampler/ https://www.tcr-tecora.com/en/outdoor-air-quality/echo-emergency-hv-high-volume-sampler/ https://www.tcr-tecora.com/en/outdoor-air-quality/echo-emergency-hv-high-volume-sampler/ ONLINE PAGE High Volume Sampler + Real Time PM ECHO EMERGENCY ECHO EMERGENCYHV is the new TCR Tecora® high volume sampler for partiHigh volume sampler with battery and culate and micropollutants sampling Vac supply in a single device; and monitoring in extreme conditions. TCR Tecora® research division highliSINGLE LINE or independent DUAL ghted the need to design a sampling LINE versions; system that can offer a viable solution in Working parameters control by Docking emergency or remote situations such as Station; fires, high mountain, isolated areas, Battery charge’s automatic control and contaminated environments to allow PTS/PM10/PM2,5/PM1 sampling on a continuous monitoring; filter with a backup sorbent trap (PUF) PM10-PM2,5-PM1up to 2000 µg/m3; for gaseous organic micropollutants OPC (0.35 a 40 µm) - 24 size classes - (PCDD/F, PCBs and PAH’s) with the max count 10000 p/s; possibility to monitor PM 10 - PM 2.5 PM1 real time trend concentrations, 24 Real time data; sizes classes particle distribuition, CO2 Integrated GPS; and relative humidity. � Sample conditioning depending on wind direction and velocity; ECHO EMERGENCYHV is also available in Dual configuration for sampling on two independent lines, also as conditional sampling, based for example on Fast charging of the battery and a safety wind speed and / or wind direction. � � RS-485 remote programming; � Remote control of the device; Ultasonic Wind Sensor System detail ECHO EMERGENCY and Docking Station. Winner Product of Air Quality Contest 2020 parameters control by Docking Station; � Flow rate up to1000 l/min. Sampling HV Sampling Head: � PTS � PM10 � PM2,5 � PM1 � PCDD/F & PCBs ECHO EMERGENCY Standard version TCR Tecora® ECHO HV Single 230 Vac Real Time OPC: �PM10 �PM2,5 �PM1 �24 channel’s OPC (with humidity and temperature sensors)

 Open the catalog to page 1
ECHO EMERGENCY HV-2

POLLUTION CHECK Docking station Operator panel’s touch screen allows to view and set ECHO EMERGENCYHV ’s control modes. Battery Charge One of the biggest limitation of portable samplers is the management of battery charge and its maintenance for ready use. ECHO EMERGENCYHV can be used at 230 - 110 Vac in case of power supply near the sampling point or otherwise battery-powered. Reports are stored in internal memory and can be exported using USB memory or RS-485 serial memory. The Docking Station is small and allows for up to 4 units to be controlled. Power 230 - 110 Vac, 24 Vdc. TCR Tecora® designed...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.