Group: tbh
Catalog excerpts
FILTER / EXTRACTION / ENVIRONMENTAL // TECHNOLOGY HUMANS / ENVIRONMENT / MACHINERY
Open the catalog to page 1Filter and extraction systems for oil and emulsion mist the OEN series at a glance Illustration similar The use of coolant/lubricants (C/L) is inevitably, not only in metalworking. They are used for cooling in processes with strong heat build-up. Fast rotations, as in machining, cause tiny droplets of the C/L to swirl into the ambient air. Particles can either be inhaled by employees during their work or settle on surfaces, such as on machine components or floors. The resulting oil film thus represents a considerable health and accident risk. For this reason, the Employer's Liability...
Open the catalog to page 2OEN 155 - OEN 250 Suitable for larger quantities of cooling-oil mist and cooling-emulsion mist. . etal processing using cooling oil and cooling emulsions with M little or no particle content . Drilling . Lathing . Milling . Eroding . Industrial baths . Work processes with high aerosol content in the process air . OEN 155 for single-station extraction . OEN 250 for multi-station extraction Illustration similar OEN 150 - OEN 710 Suitable for medium quantities of cooling-oil mist and cooling-emulsion mist with particle content. . etal processing using cooling oil and cooling emulsions with M...
Open the catalog to page 3Applications OEN 155 - 250 This series was developed for the extraction of oil and emulsion mist. Especially when operated in the metalworking industry or with industrial baths, the system can extract from the air and then filter the hazardous oil mist and oil-emulsion mist with low particle content developing in the process. Special filter cartridges guarantee reliably long service life and very effective separation of even large quantities of liquids. Usage of two OEN 250s The P & R Günthner GmbH company in Bad Wildbad, Baden-Wuerttemberg, uses two OEN 250s for the extraction of oil mist...
Open the catalog to page 4Applications OEN 150 - 710 This series was developed for the extraction of emulsion mist. It is particularly suitable in metalworking for applications with low content of oil-emulsion mist, yet at the same time with medium particle content in the contaminated air. The aluminium mesh and the saturation filters ensure effective liquid separation along with optimised particle separation. Usage of an OEN 710 The Spilker GmbH company in Leopoldshoehe, North Rhine-Westphalia, uses an OEN 710 for the extraction of C/L mist from machine tools. Spilker GmbH - OEN 710 Metalworking - CNC milling...
Open the catalog to page 5Application-dependent filter equipment Various filter configurations possible depending on application. OEN 155 / 250 Special filter cartridges are used for pure oil mist and oil-emulsion mist with very low particle content. They guarantee long service life and very effective separation of even large quantities of liquids. OEN 150 - OEN 710 The systems are suitable for processes with low content of oil-emulsion mist, yet at the same time with medium particle content. The aluminium mesh and the saturation filters ensure effective liquid separation along with optimised particle separation....
Open the catalog to page 6Easy filter changing OEN 155 Filter change Filter change Filter exchange takes place simply by removing the particle filter and filter cartridge from above. Collection container With the OEN 155, the liquid can be disposed of via the collection container. Filter change Filter change To change the cartridge, remove it from above. Remove the filter via the front doors to the front. Drain valve With the OEN 250, the liquid can easily be disposed of via the mounted drain valve. HUMANS / ENVIRONMENT/ MACHINERY
Open the catalog to page 7Easy filter changing OEN 150 Filter exchange takes place simply by removing the filters from above. Collection container With the OEN155, the liquid can be disposed of via the collection container. Filter change Filter change The filter is changed via the front doors to the front. Open the front doors and remove the filter towards Drain valve the front. With the OEN 710, the liquid can easily be disposed of via the mounted drain valve. HUMANS / ENVIRONMENT/ MACHINERY
Open the catalog to page 8Inspiring checking Always full control over the system . A - Start / Stop button . B - Manual power control . 1 - Saturated filter notification . 2 - System status indication . 3 - ower-setting indication/ P Hour meter . 4 - emperature and turbine-status T indication . 5 - Filter status indication Sub-D 25 interface External control of the system Powerful control unit . Start / Stop button . "Filter full" pre-warning stage (75%) . Group-error output (speed, temperature, "filter full" 100%) . External power control . arameterization access for P activating special functions . Message cache ....
Open the catalog to page 9Delivery scope: . Fully mounted (incl. individual filter equipment) . lease order position and dimensions of the P connection socket separately. . Power cord Illustration similar TECHNICAL DATA Air flow rate with free air delivery Effective air volume flow Motor output Continuous running Sound level Drive type Serial interface Dimensions (HxWxD) Collection container FILTER CONFIGURATION Oil/emulsion mist filter cartridge F9 Particle filter H13 Active carbon filter HUMANS / ENVIRONMENT/ MACHINERY
Open the catalog to page 10WITH ACTIVATEC-CARBON FILTER MODULE Activated-carbon filter module Machine base* * or mobile use, the height of the system increases by approx. f 100 mm SPARE FILTER SPARE FILTER Filter cartridge Filter cartridge Particle filter Particle filter Active carbon filter/ filter Active carbon filter/ filter INTAKE SOCKET Left NW 50 HUMANS / ENVIRONMENT/ MACHINERY
Open the catalog to page 11Delivery scope: . Fully mounted (incl. individual filter equipment) . Base stands (suitable for forklift trucks) . Crane eyelets (optional) . Power cord Illustration similar TECHNICAL DATA Air flow rate with free air delivery Effective air volume flow Motor output Class of protection Drive type Continuous running Sound level Serial interface Dimensions (HxWxD) - basic model Dimensions (HxWxD) - with 1 expansion module Dimensions (HxWxD) - with 2 expansion modules Minimum ceiling height for filter removal - basic model Minimum ceiling height for filter removal - with 1 expansion module...
Open the catalog to page 12All TBH GmbH catalogs and technical brochures
-
TBH medican and aesthetics
24 Pages
-
BF SERIES
24 Pages
-
DT 100/150
12 Pages
-
FP 150 ATEX
16 Pages
-
FP 150
18 Pages
-
FP 200 ATEX SERIES
20 Pages
-
FPV 100
10 Pages
-
FPV 202
16 Pages
-
GL 265
16 Pages
-
FP 200 SERIES
22 Pages
-
GL DESK
12 Pages
-
GL SERIES
22 Pages
-
LN 200 SERIES
26 Pages
-
LN 600 SERIES
20 Pages
-
TFS SERIES
18 Pages
-
CR SERIES
16 Pages