Overview: The document provides technical specifications for the TP280 series High DC Inverter models TP281, TP282, and TP283 by TBB Power Co., Ltd. It covers electrical safety, environmental conditions, and performance parameters.
Specifications:
  • Operating Temperature: -10°C to 50°C
  • Storage Temperature: -40°C to 85°C
  • Nominal Voltage: 240VDC
  • Isolation: AC-DC and DC-ground isolation at 2000Vrms
  • Operating Voltage Range: 200VDC to 310VDC
  • Voltage Range: -25% to +20%
  • Frequency Range: ±10%
Output Characteristics:
  • Output Power: 1KVA, 2KVA, 3KVA
  • Waveform: Pure sine wave
  • Power Factor: 0.8
  • Nominal Output Voltage: 110/120VAC, 220/230/240VAC
  • Voltage Variation: Max ±2%
  • Output Frequency: 50/60Hz ±0.1%
  • THD: <3% for linear load, <5% for non-linear load
  • Crest Factor: 3:1
  • Efficiency: Max 90%
  • Overload Capacity: 150% for 1 minute, 125% for 10 minutes
  • Transfer Time: 5-8ms
  • Dynamic Response Time: <20ms
Safety and Standards:
  • Safety Standard: EN60950-1
  • Emission Standard: EN55022
  • Immunity Standard: EN55022
Communication and Display:
  • Communication Interfaces: RS485 or RS232
  • Display: LCD + LED
  • Dry Contacts: 4 x Dry contact
See more

Catalog excerpts

TP280 sereis-1

TBB POWER CO.,LTD. Tel: 86-592-5212299 Fax: 86-592-5796070 website: www.tbbpower.com Email: [email protected] TP280 sereis High DC Inverter Electrical Safety & Enviroment Model TP281, TP282, TP283 DC Input Norminal Voltage 240VDC Operating range 200VDC-310VDC AC Input Voltage range :-25% - +20% Frequency range : ±10% AC Output Output power 1KVA, 2KVA, 3KVA Wave form Pure sine wave Power factor 0.8 Norminal output 110/120VAC, 220/230/240VAC Voltage variation Max ± 2% Output frequency 50/60Hz ± 0.1% <3% liner load THD <5% non-liner load Crest factor .3:1 Efficiency Max 90% Overload 150% 1min 125% 10mins Transfer time 5-8ms Operating Temp. : -10C - 50C Storage Temp. : -40C - 85C Isolation AC - DC : 2000Vrms DC - ground : 2000Vrms AC - ground : 2000Vrms Dynamic response time All parameters Working status Failure alarm Communication RS485 or RS232 Dry contact 4 x Dry contact Standard Safety Emmission Immunity