The document is a user guide for Tavrida Electric's withdrawable vacuum circuit breakers (VCBs), suitable for voltages up to 17.5 kV. These are designed for indoor use in air-insulated switchgear panels, handling both normal and faulty network operations. Key components include the Indoor Switching Module (ISM) and the microprocessor-based Control Module (CM) for operation, protection, and data logging.
Technical Specifications
The VCBs comply with standards such as EC 62271-100 and GB 1984-2003. Specifications include rated voltage, current, withstand voltages, mechanical life, operating sequences, and power consumption.
Handling and Installation
Proper handling involves using original packaging and avoiding impacts. Installation requires checking connections to prevent overheating and ensuring proper earthing. Secondary connections use specific plugs, and auxiliary circuits must be installed correctly.
Warranty and Precautions
The warranty is contingent on adherence to operating and storage guidelines, with unauthorized modifications voiding it. Precautions include ensuring suitable installation sites and compliance with safety regulations.
Commissioning and Maintenance
Commissioning involves checks for installation and functionality, including visual inspections and relay contact tests. Maintenance is minimal under normal conditions, with inspections recommended every five years or more frequently in adverse conditions.
Standards and Environmental Considerations
The document highlights the use of environmentally friendly materials, negating the need for special waste disposal. It also includes appendices with drawings and secondary schemes for different plug types.
Contact and Legal Information
Contact details for Tavrida Electric offices worldwide are provided, along with a legal notice regarding the document's use and liability.
See more

Catalog excerpts

Withdrawable VCB15-25 User Guide-1

(ZEp TAVRIDA ELECTRIC Excellence in Engineering VACUUM CIRCUIT BREAKER USER GUIDE

 Open the catalog to page 1
Withdrawable VCB15-25 User Guide-6

This User Guide describes the withdrawable vacuum circuit breakers manufactured by Tavrida Electric. Tavrida Electric circuit breakers are designed for rated voltages up to 17.5 kV. Withdrawable vacuum circuit breakers are designed for indoor installation in air-insulated switchgear panels and are intended to perform switching operations in network rated and faulty modes. The breakers consist of the following main components: • Indoor Switching Module (ISM) - The air-insulated ISM incorporates Tavrida Electric vacuum interrupters incorporated in solid dielectric insulator controlled by per phase...

 Open the catalog to page 6
Withdrawable VCB15-25 User Guide-7

The break time is the time period from the moment the trip command is applied to the CM to the time when the arcs in all phases are extinguished. 1.3 Main Technical Parameters Main technical data and circuit breaker technical parameters are presented in the tables below. Table 1 - Main Technical Parameters 1) Rating for metal-enclosed switchgear with limited ventilation. Temperature rise type test at 2500 A in Cradle was successfully passed in KEMA. 2) For PCD 275 mm 3) The information in parentheses is in accordance with the national Chinese standard GB1984-2003 at an installation altitude of...

 Open the catalog to page 7
Withdrawable VCB15-25 User Guide-8

For 2000 A For 3150 A At Cos j > 0.66. At Cos j > 0.33. Up to an installation altitude of 1000 m above sea level. Above 1000 m, the external insulation measurement of the VCB must be increased by the atmospheric correction factor Ka in accordance with IEC 62271-1 compared to the insulation measurement at sea level. The maximum allowed altitude is 2000 m above sea level. 1.4 Disclaimers Tavrida Electric will not accept any claims for damages caused by improper transport, storage as well as unpacking. Transport damage must be reported in writing to the supplier as soon as it is discovered. The...

 Open the catalog to page 8
Withdrawable VCB15-25 User Guide-10

The vacuum circuit breaker itself does not have labels or seals; however, its main components (ISM, CM and manual generators) have them. VCB, ISM Labels and Seals Each VCB has an electrical data label with a serial number: The electrical data label contains information about the VCB type, its technical parameters and serial number. The placement of the electrical data label is shown below. Figure 2 Electrical data label placement The serial number plate contains information about the ISM type and serial number. The label contains brief information about the VCB technical parameters. There are...

 Open the catalog to page 10
Withdrawable VCB15-25 User Guide-11

Figure 3 ISM warranty seal Figure 4 ISM warranty seal labels arrangement CM Labels and Seals Each CM has the following labels:       Serial number label Label with applicable ISM designation Warranty seal labels Warning label Firmware version label Information label with terminals connections and main parameters Serial number label Label with applicable ISM de

 Open the catalog to page 11
Withdrawable VCB15-25 User Guide-12

Serial number label Label with applicable ISM designation Warning label Warranty seal Firmware version label Information label with terminals connections and main parameters

 Open the catalog to page 12
Withdrawable VCB15-25 User Guide-13

Figure 11 Designation label

 Open the catalog to page 13
Withdrawable VCB15-25 User Guide-15

3.1 Transportation The VCBs are transported in the original package only. Any kind of transport and combinations thereof are applicable. Transportation shall be provided in waterproof compartments. If air transportation is used all products shall be transported inside heated, pressurized compartments. Packages with goods shall be handled in accordance with the handling symbols. Loading procedures for VCB package shall be carried out only using forklifts, hoists or cranes. During transportation the VCB must not be subjected to sharp impacts or dropped. 3.2 Storage If immediate installation is...

 Open the catalog to page 15
Withdrawable VCB15-25 User Guide-16

Figure 15 VCB components on the pallet

 Open the catalog to page 16
Withdrawable VCB15-25 User Guide-17

Unscrew withdrawable VCB fastening provisions as shown below. Figure 16 Unfastening the withdrawable VCB Figure 17 Withdrawable ISM lifting provisions To lift and handle the circuit-breaker, proceed as shown in Figure 17 b). The special lifting tool is not supplied. The lifting brackets of the VCB should be removed before using the withdrawable VCB. All items should be checked visually for:  Mechanical damage, scratches, discoloration, corrosion.  Damage to the warranty seals (Figure 4, Figure 10). Any transport damage must be reported immediately to the carrier in writing. Damages shall be...

 Open the catalog to page 17
Withdrawable VCB15-25 User Guide-18

VCB Packaging and Scope of Supply The VCB is placed in a metal box on the pallet (Figure 19) with following labels:  Handling symbols label for transport and storage of the delivery unit (Figure 18).  Labels for manufacturers and product information (Figure 20). The VCB scope of supply is presented in the VCB packing list. 1. Fragile, handle with care Keep dry This side up Stacking level limitation Figure 18 Handling symbols Figure 19 Label for manufacturers‘ and product information The VCB delivery set contains: 1. Withdrawable VCB 2. CM 3. CBkit_Plug_1 The ISM shall have undamaged warranty...

 Open the catalog to page 18
Withdrawable VCB15-25 User Guide-19

CM Packaging and Scope of Supply As part of the VCB, the CM is delivered inside of the VCB package. The CM is packed in cardboard a box. Manufactur er Product name Device type Serial number Product code Handling symbols Figure 22 CM package labeling The CM shall have undamaged warranty seals (its placement on the CM is shown in Figure 10). The CM designation and serial number shall comply with data in the VCB packing list and the CM routine test certificate. Each CM includes the following components: CBkit_Plug_1 Scope of Supply As part of the VCB, the CBkit_Plug_1 is placed inside the VCB package....

 Open the catalog to page 19
Withdrawable VCB15-25 User Guide-20

1. Manufacturer Device type Product name Product code Figure 25 CBkit_Plug_1 package labeling 1. Cover for wiring Socket pins Plastic insert Screwdriver Lever

 Open the catalog to page 20
Withdrawable VCB15-25 User Guide-21

1. Socket pins Plastic insert Coding pins Plug hood Screwdriver Lever VCB Accessories Unpacking and Checkup CBunit_ManGen_1 and CBunit_ManGen_2 Packaging and Scope of Supply The CBunit_ManGen is used to charge CM_16 in cases when main auxiliary power supply is unavailable. It is packed in a cardboard box. 1. Manufacturer Type of device Product name Product code Handling symbols Serial number Figure 29 CBunit_ManGen_1 package labeling

 Open the catalog to page 21

All TAVRIDA ELECTRIC NORTH AMERICA catalogs and technical brochures

  1. VCB15_HD1_16F

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.