Rec15-25 User Guide

Rec15-25 User Guide
1 / 136 PagesView full catalog

Rec15-25 User Guide

Product catalog summary
Overview: This document provides comprehensive guidelines for the Rec15/25 series automatic reclosers, covering transportation, storage, installation, commissioning, operation, troubleshooting, decommissioning, and disposal. It includes descriptions of functional parts, accessories, and functionality, directing users to the Product Guide on the Tavrida Electric website for detailed information.
Intended Audience: The document is intended for procurement personnel, fitters, commissioning engineers, operatives, and asset management teams, emphasizing thorough reading and equipment inspection before installation or operation.
Safety Instructions: Only qualified personnel should handle electrical equipment, adhering to local safety regulations to prevent hazards from contact with hazardous voltage.
Abbreviations: A list of abbreviations is provided, including terms like ABR (Automatic Backfeed Restoration), BAT (Battery), and SCADA (Supervisory Control And Data Acquisition).
Contents Overview: The document is structured into sections including:
  • Product Description: Application field, main components, and technical parameters.
  • Nameplates and Seals: Identification and sealing of components.
  • Product Handling: Guidelines on transportation, storage, inspection, unpacking, and handling.
  • Installation: Procedures for installing components like the Outdoor Switching Module (OSM) and Recloser Control Cubicle (RC).
  • Commissioning: Instructions for no-load and on-load tests.
  • Operation: Details on switching operations, logging, measurements, and control options.
Critical Safety Notes: Hazard statements and warnings emphasize isolating equipment from voltage sources and proper handling of power distribution equipment.
Specifications: Equipment features PVC-coated steel armored cables with heavy-duty connectors. The control module allows safe unplugging of the umbilical cable during operation.
Technical Parameters: Lists rated voltages, current capacities, withstand voltages, mechanical life, operating cycles, and environmental conditions.
Measurement and Compatibility: Tables provide accuracy ranges for sensors and measurement errors, ensuring compliance with international standards.
Handling and Transportation: Emphasizes careful handling during transportation, with guidelines for lifting and securing equipment.
Inspection and Unpacking: Includes an inspection checklist and unpacking instructions for pole-mounted and substation reclosers.
Handling Requirements: Outlines specific handling requirements to prevent equipment damage.
Mounting Kit Preparation: Instructions for preparing the pole mounting kit and repositioning components.
Installation Procedures: Detailed steps for frontal and lateral installation, substation mounting kit preparation, and required equipment.
Commissioning: Perform no-load tests, check power supply and settings, and conduct phase sequence check-up.
On-load Tests: Verify phase currents, power factors, and power measurements.
Operation: Includes switching, operation via MMI, logging, measurements, and date/time settings.
RC5_4 Control Options: Control and indication via PC using TELARM software, with various connection types.
Settings Modifications: Protection and communication settings can be modified and uploaded to the device.
Maintenance and Troubleshooting: The device is maintenance-free, with troubleshooting procedures for common issues.
Troubleshooting Procedures: Steps for identifying and correcting malfunctions.
Component Replacement Procedures: Detailed steps for replacing components like RCM, CPM, PSFM, and battery.
Disposal: Recommendations for environmentally responsible disposal and recycling.
Appendices: Includes technical drawings, wiring diagrams, and spare parts information.
Product Specifications: Lists specifications for control panels, batteries, and kits.
Document Changes: Lists changes across document versions, including new features and descriptions.
See more

Catalog excerpts

Rec15-25 User Guide-1

(ZEp TAVRIDA ELECTRIC Excellence in Engineering AUTOMATIC CIRCUIT RECLOSER

 Open the catalog to page 1
Rec15-25 User Guide-2

This document contains information on Rec15/25 series automatic recloser transportation, storage, installation, commissioning, operation, troubleshooting, decommissioning and disposal. This document also contains a basic description of the Rec15/25 series autoreclosers functional parts, accessories and functionality. For a detailed functionality and component description refer to the Product Guide. The Product Guide can be downloaded from the Tavrida Electric website or obtained from a Tavrida Electric representative. This document is intended for the following audiences:      Procurement...

 Open the catalog to page 2
Rec15-25 User Guide-3

ABR Automatic Backfeed Restoration BAT Battery BF Bolted Fault BTM Bluetooth Module CC Control Cable (Umbilical) CCV Close condition verifier CLP Cold Load Pickup CPM Control Panel Module CT Current Transformer CU Current unbalance D Delayed EF Earth Fault protection element EF1 Low set Earth Fault protection element for Delayed trips EF2 Low set Earth Fault protection element for Instantaneous trips EF3 High set Earth Fault protection element for Instantaneous trips EL Event Log ETH Ethernet Module I Instantaneous I/O Input/Output IOI Input/Output Interface IOM Input/Output Module LCD Liquid...

 Open the catalog to page 3
Rec15-25 User Guide-4

RTU Remote Telecommunication Unit SCADA Supervisory Control And Data Acquisition SD Source Detector SEF Sensitive Earth Fault SEFR Sensitive Earth Fault with reclosing SI Synchronization indicator TEL Tavrida Electric TCI Telecommunication Interface TDI Telarm Dispatcher Interface UF Under Frequency UV Under Voltage VRC Voltage Reclosing Control VT Voltage Transformer VU Voltage Unbalance ZSC Zone Sequence Coordination

 Open the catalog to page 4
Rec15-25 User Guide-10

1.1 Product Application Field Reclosers can be applied in overhead distribution lines. The main applications are: • Clearing transient faults by performing autoreclosing; • Isolating sustained faults in the overhead line network; • Isolating sustained faults in a network where conventional protection coordination is not possible; • Automatic backfeed restoration. The recloser can also be used at outdoor substations feeding overhead distribution lines for: • Substation outgoing feeder with autoreclosing functionality; • Substation busbar coupler with backfeed restoration capability; • Substation...

 Open the catalog to page 10
Rec15-25 User Guide-11

Mechanical Trip and Lockout Mechanism A mechanical trip hook is located at the bottom of the tank (Figure 3). When the hook is pulled down, the OSM is mechanically tripped, locked in the OPEN position and electrically isolated from the driver. An “OSM Coil Isolated” warning event is generated by the RC5_4 to provide indication of the locked state. The OSM remains locked and cannot be operated until the trip hook is pushed back into the operating position. Figure 3 Mechanical trip hook Mechanical Position Indicator The position indicator is located under a protective cover at the bottom of the...

 Open the catalog to page 11
Rec15-25 User Guide-12

1. Three-point locking system 4. 2 x IP65 glands for Power supply cable (0 9... 17 mm) 5. Anti-vandal cover of Control Cable 7. Control panel module 9. Thermal overcurrent circuit breakers 10. Dust proof drainage filter 14. Battery circuit breaker 15. Door position switch 1. Door position switch 2. Remote telecommunication unit (RTU) mounting plate 3. Place for Inpul/Output module (10M) 4 Recloser Control Module (RCM) 5. Battery 6. Power supply filter module Figure 6 RC5_4 with internal door open

 Open the catalog to page 12
Rec15-25 User Guide-13

Figure 7 Control cable connection The RC5_4 cubicle is equipped with stainless steel earthing provision with M12x30mm bolt: All internal components and parts are earthed to the main RC cubicle with 2.5 mm2 copper earthing jumpers. The housing has provisions for protection against dust and water ingress. Figure 8 RC housing provisions The RC5_4 is equipped with a Door Position Switch which is used for disabling the CPM at closed RC, as well as a SCADA indication of the RC door position. The door position switch is mounted on the internal door and actuated by the lever mounted opposite to the switch...

 Open the catalog to page 13
Rec15-25 User Guide-14

Control Panel Module (CPM) The CPM provides local control and indication functions of the Rec15/25 (Figure 10). Control buttons and indication LEDs are located at the front side of the CPM (Figure 11). The CPM has an integrated USB interface for PC connection. Figure 10 Control panel module (CPM)

 Open the catalog to page 14
Rec15-25 User Guide-15

14. Earth Fault ON/OFF IS. Sensitive Earth Fault ON/OFF 17. Hot Line ON/OFF IS. Backfeed Restoration ON/OFF 19. Active (Protection) Group 1. TEL Logo 2. Title string 3. Label of Indication data. Control data or Settings 10. Parameter values of Indication data. Control data or Settings

 Open the catalog to page 15
Rec15-25 User Guide-16

Recloser Control Module (RCM) The RCM is the recloser control module. The RCM provides protection, communication, measurement and control functions. RCM connections with other RC modules Power supply filter module (PSFM) The PSFM is used for an RC5_4 auxiliary power supply connection (Figure 14). This module provides impulse noise protection for all internal modules of the RC5_4. Figure 14 Power supply filter module The rechargeable battery provides the RC5_4 with auxiliary power when the main auxiliary power is not present. The power supply system is designed to provide battery optimum charging...

 Open the catalog to page 16
Rec15-25 User Guide-17

The RC can be supplied with an IOM (Figure 15) module on request It provides control and indication functions with the aid of digital inputs/outputs. Figure 15 Input/Output module The IOM contains twelve digital inputs and twelve digital outputs. The location of these connectors (marked “15”…”18”) with these inputs and outputs are shown in Figure 16. Figure 16 Location of IOM connectors Digital inputs are potentially isolated by means of opto-couplers (Figure 17). Figure 17 Digital inputs Bistable relays with changeover contacts are used for the digital outputs as illustrated in Figure

 Open the catalog to page 17
Rec15-25 User Guide-18

Figure 18 Digital outputs Technical parameters of Input/Output Module are in Table 8. 1.2.2.6 Ethernet interface module can be supplied as an accessory. Wired Ethernet module Ethernet module provides full remote (SCADA) and local communication and engineering functionality via RJ45 port. Figure 19 Ethernet module installed on RCM Technical parameters for Ethernet interface in Table 9. Wired ethernet module starts working automatically after Network settings setup for corresponding interface is completed. LED indication description:  Green LED – Indicating the network connection speed. Glowing...

 Open the catalog to page 18

All TAVRIDA ELECTRIC NORTH AMERICA catalogs and technical brochures

  1. VCB15_HD1_16F

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.