Rec15-25 Product Guide

Rec15-25 Product Guide
1 / 133 PagesView full catalog

Rec15-25 Product Guide

Product catalog summary
Introduction
This document serves as a product guide for Tavrida Electric's automatic circuit reclosers, intended for use in overhead distribution lines and outdoor substation switchgear with a rated voltage up to 27kV. It is designed for application engineers and utilities technical personnel, providing information on technical parameters, functionality, and operating principles.
Abbreviations
A list of abbreviations used in the document is provided, including terms like ABR (Automatic Backfeed Restoration) and BTM (Bluetooth Module).
Product Application and Benefits
Reclosers are used for clearing transient faults, isolating sustained faults, and automatic backfeed restoration in overhead distribution lines and outdoor substations. Key benefits include maintenance-free operation, lightweight design, sophisticated measurement systems, environmental friendliness, and operation without a backup battery. The reclosers comply with international standards.
Product Coding
The document details the coding system for reclosers and their components, allowing for model and part identification.
Technical Parameters
Technical specifications include rated maximum voltage, short-circuit breaking current, mechanical life, and environmental conditions. Parameters for sensors and measurement accuracy are also detailed.
Design and Operation
The design includes components like the Outdoor Switching Module and Protective Tank. Operation details cover opening and closing procedures.
Functionality
Protection elements, measurement capabilities, communication interfaces, and remote engineering features are discussed.
Application Notes
Guidance is provided on mounting kits, primary line connections, telecommunication equipment, and auxiliary supply.
Appendices
Includes type tests, spare parts, dimensions, and a list of changes.
Battery Specifications
Details on HAZE HZB12-26 sealed lead acid batteries, including voltage, capacity, and operating temperature range.
Input/Output Module Parameters
Specifications for digital inputs and outputs, including voltages and currents.
Communication Modules
Parameters for Ethernet, Bluetooth, and Wi-Fi modules, including standards supported and operational ranges.
Recloser Control Features
Components like the Control Panel Module and Recloser Control Module provide advanced functionalities.
Specifications
Details on Ethernet module standards, dimensions, and operational conditions.
Operation Procedures
Describes opening and closing operations, including mechanical and electronic methods.
Protection and Control Elements
Overview of protection applications, fault locator, cold load pickup, and various protection elements like OCR Mode and Source Detector.
Flag Reset and Loss of Supply
Features for resetting flags and handling loss of supply, including autoreclosing settings.
Advanced Protection Features
Includes REZIP, Zone Sequence Coordination, Hot Line, Sensitive Earth Fault, and Neutral Admittance Protection.
Communication Interfaces
Details on interfaces for data management and remote control, including TELARM software and Telecommunication Interface.
Connection and Communication Interfaces
Various interfaces for establishing connections and managing data and firmware.
Specifications and Connectors
Details on connectors and protective measures for line connections.
Telecommunication Equipment
Features of the RC5_4 unit for communication with remote systems.
Auxiliary Supply
Specifications for auxiliary supply connections and safety features.
Type Tests
Lists tests conducted to ensure compliance with standards.
Spare Parts and Accessories
Information on available spare parts and accessories.
Dimensions
Dimensions for various components and mounting kits.
Document Version History
Details changes and updates made in different versions of the document.
See more

Catalog excerpts

Rec15-25 Product Guide-1

(ZEp TAVRIDA ELECTRIC Excellence in Engineering AUTOMATIC CIRCUIT RECLOSER

 Open the catalog to page 1
Rec15-25 Product Guide-4

This Product Guide describes automatic circuit reclosers manufactured by Tavrida Electric. Tavrida Electric autoreclosers are designed for overhead distribution lines and outdoor substation switchgear with rated voltage up to 27kV. Important! Due to continuous product improvement, specifications and design are subject to change without notice. The main components of the autorecloser are: Outdoor Switching Module (OSM) The air insulated OSM incorporates a Tavrida Electric vacuum circuit breaker with per phase magnetic actuators housed in a tank made of corrosion resistant aluminum alloy. Six main...

 Open the catalog to page 4
Rec15-25 Product Guide-5

1.1 Abbreviations ABR Automatic Backfeed Restoration AT Auxiliary Transformer BAT Battery BF Bolted Fault BTM Bluetooth Module CC Control Cable (Umbilical) CCV Close condition verifier CLP Cold Load Pickup CPM Control Panel Module CT Current Transformer CU Current unbalance D Delayed EF Earth Fault protection element EF1 Low set Earth Fault protection element for Delayed trips EF2 Low set Earth Fault protection element for Instantaneous trips EF3 High set Earth Fault protection element for Instantaneous trips EFID Earth Fault Interruption Detection EL Event Log ETH Ethernet Module HL Hot Line...

 Open the catalog to page 5
Rec15-25 Product Guide-6

PCI Personal Computer Interface PSFM Power Supply Filter Module RC Recloser Control Cubicle RCM Recloser Control Module RTC Real Time Clock RTU Remote Telecommunication Unit SA Surge Arrester SCADA Supervisory Control And Data Acquisition SD Source Detector SECR Sectionalizer Reclosing SEF Sensitive Earth Fault SEFID Sensitive Earth Fault Interruption Detection SEFR Sensitive Earth Fault with reclosing SI Synchronization indicator TCI Telecommunication Interface TDI TELARM Dispatcher Interface TEL Tavrida Electric UF Under Frequency UV Under Voltage VRC Voltage Reclosing Control VT Voltage Transformer...

 Open the catalog to page 6
Rec15-25 Product Guide-8

2.1 Product Application Field Reclosers can be applied in overhead distribution lines. The main applications are:  Clearing transient faults by performing autoreclosing;  Isolating sustained faults in the overhead line network;  Isolating sustained faults in a network where conventional protection coordination is not possible;  Automatic backfeed restoration. The recloser can also be used at outdoor substations feeding overhead distribution lines. It may be used as:  Substation outgoing feeder with autoreclosing functionality;  Substation busbar coupler breaker with backfeed restoration...

 Open the catalog to page 8
Rec15-25 Product Guide-10

Table 1 - Recloser coding description

 Open the catalog to page 10
Rec15-25 Product Guide-12

Each OSM has the following nameplates: • Serial number plate • Parameters nameplate

 Open the catalog to page 12
Rec15-25 Product Guide-13

Nameplate and serial number plate placement The serial number plate contains information about the OSM type and serial number. The nameplate describes OSM technical parameters. RC coding RC5_4M(P1…P12) Recloser control RC type Table 3 – RC coding description Parameter Parameter description Applicable options Code extended Power outlet –15 degrees rated battery Wired Ethernet (RJ45 interface) Local wireless access Optical Ethernet Recloser control cubicle RC5_4 Input-output module –40 degrees rated battery Battery type –25 degrees rated battery Battery ready Firmware version According to customization...

 Open the catalog to page 13
Rec15-25 Product Guide-14

Each Control cable has a colored tube with serial number.

 Open the catalog to page 14
Rec15-25 Product Guide-15

Figure 5 Control cable tie with serial number

 Open the catalog to page 15
Rec15-25 Product Guide-18

Table 5 - Recloser technical parameters

 Open the catalog to page 18
Rec15-25 Product Guide-19

Figure 6 Life cycle of OSM Table 6 - Sensors parameters 3 The Rogowski coil can measure current in a wide range but for the purpose of over-voltage, protection suppressors are fitted in the secondary circuits. These suppressors chop the signal from the Rogowski coil if primary current exceeds 8 kA. 4 If RC5_4 sensor coefficient settings are configured in accordance with guidelines in Table 6 of this guide. Error is measured at normal climatic conditions. 5 Note that overcurrent protection pickup setting value shall not exceed SEF pickup setting value times 300.

 Open the catalog to page 19
Rec15-25 Product Guide-20

Table 8 - Electromagnetic compatibility 6 Note that additional DC circuit breakers are required. For details refer to section „7.3 Auxiliary supply“ of this guide. 7 Only the battery types described in this guide can be used in the RC.

 Open the catalog to page 20
Rec15-25 Product Guide-21

Table 12 - Input/Output module (IOM) parameters

 Open the catalog to page 21
Rec15-25 Product Guide-22

Table 15 - Bluetooth module (BTM) parameters

 Open the catalog to page 22
Rec15-25 Product Guide-24

5.1 Design 5.1.1 Outdoor Switching Module The OSM is equipped with six high voltage bushings with embedded current and voltage sensors. The bushings are covered by silicone rubber insulation which mount on the top of the tank and provide 500 mm (OSM15) or 860 mm (OSM25) creepage distance. The bushings are marked with the terminal designation X1, X2 or X3 for the default source side and X4, X5 or X6 for the default load side. The source and load side can be reversed in the RC settings if required. Terminal Six HV silicone bushings Current and voltage sensors built into the bushings Vacuum circuit...

 Open the catalog to page 24
Rec15-25 Product Guide-25

and X6 terminals have secondaries connected in series for residual current measurement. Capacitive sensors for voltage measurement are inbuilt in all six bushings. For details on sensor parameters refer to section „4. Technical parameters“ of this guide. 5.1.4 Main Contact Position Indicator The position indicator is located under a protective cover at the bottom of the tank and is clearly visible from the ground. The indicator color is red I when the OSM is closed and green O when it is open. Figure 9 Main contact position indicator 5.1.5 Vacuum Circuit Breaker The essence of OSM is Tavrida...

 Open the catalog to page 25
Rec15-25 Product Guide-26

Upper terminal Vacuum interrupter Lower terminal Movable contact with bellows Flexible junction shunt Drive insulator Opening and contact pressure spring Magnetic actuator (complete module) Armature Synchronizing shaft Actuator coil Interlocking pins Auxiliary contacts Frame Support insulator Figure 10 View into the Vacuum Circuit Breaker 5.1.6 Control Cable Umbilical_4 control cable connects the OSM actuators, metering and auxiliary wiring to the RC5_4. Control cable wires are each protected by a PVC coated steel armored sleeve. The cable is equipped with a heavy duty 42 pin male connector on...

 Open the catalog to page 26