Light Curtain Catalog - 1

^m^mt SWITCH PRODUCTS SAFETY & SIGNAL MATS SENSING EDGES m^^^M SENSING BUMPERS SAFETY INTERFACE MODULES ^■HE LIGHT CURTAINS CUSTOM DESIGNS SAFETY INTERLOCKS

Open the catalog to page 1
Light Curtain Catalog - 2

CONTENTS pg. 2 B-Series Light Curtains Full-featured and sophisticated Self-contained, wires directly to machine or controller UL / CE Listed pg. 3 B-Series Perimeter Guards Available with 2, 3 or 4 beams Operating distance of up to 30 meters pg. 4 B-Series Master/Slave Guards Full-featured and sophisticated Self-contained, wires directly to machine or controller UL / CE Listed pg. 5 Hard-Guard Enclosed Light Curtain pg. 6 Suitable for indoor or outdoor applications Impervious to water, dust, dirt, and oil pg. 7 -9 pg. 9 - 10 Light Curtain Accessories Cable, brackets, floor stands and...

Open the catalog to page 2
Light Curtain Catalog - 3

B-SERIES LIGHT CURTAINS The B-Series Safety Light Curtains are full-featured, microprocessor-controlled units. Special capabilities include beam blanking and a flexible interface that is compatible with common safety relay units, controllers (SIM), and fail-safe PLC's. A wide range of sizes and resolutions are available. The B-Series emitter and receiver pair, by themselves, constitutes a complete light curtain system, which provides two redundant solid state PNP type outputs and is a type 4 safety device in accordance with EN 61496-1. These outputs can be interfaced directly into the...

Open the catalog to page 3
Light Curtain Catalog - 4

B-SERIES PERIMETER GUARDS Tapeswitch Type B2, B3, & B4 Perimeter Guards are designed for safety and security applications. They are used to protect hazardous areas such as automated work cells and to monitor access or traffic in secure locations. The difference between models is the beam spacing. These photoelectric devices provide the same high level category 4 safety integrity as the B-Series light curtains. To simplify installation, the emitter and receiver pair make up a self-contained system which is capable of safety functions without additional equipment. Features & Benefits ■...

Open the catalog to page 4
Light Curtain Catalog - 5

B-SERIES MASTER/SLAVE GUARDS The B-Series master/slave system is a cascading light curtain guarding system, which offers a solution for those applications that require detection on two planes from one point. It consists of a maximum of two slave units connected to either a basic or multi-beam master system, which are offered in defined detection ranges in 14 mm (24 beams per 200 mm curtain), 30 mm (12 beams per 200 mm curtain), or 70 mm (4 beams per 200 mm curtain) in sizes from 200 -1800 mm increments. Master/slave units can be configured to a 144 beam maximum. Other features include beam...

Open the catalog to page 5
Light Curtain Catalog - 6

HARD-GUARD LIGHT CURTAINS The Hard-Guard Light Curtain is designed for harsh industrial applications. It is available in either a tough transparent acrylic housing or a rugged aluminum enclosure. Protected against water (including wash down), dust, dirt, oil, and many solvents, it is ideal for heavy industrial applications, food processing, or outdoor safety and security systems. The Hard-Guard system includes a full featured light curtain and a matching controller. It easily interfaces with a wide range of machine or security controls. Consult factory application engineer for more...

Open the catalog to page 6
Light Curtain Catalog - 7

B-SERIES LIGHT CURTAIN ACCESSORIES Cable Assemblies Cable assemblies are used to connect the B-Series sensing units to a controller or machine. The emitter has a 5-wire cable and the receiver has an 8-wire cable. One end of each cable has a keyed quick-disconnect connector and the other end is unterminated. The cables are IP68 rated, and UL and CSA recognized. Order cables separately. Cable Assemblies P/N Cable Assemblies P/N Emitter Cable, 15 ft. 5 Conductor 0972 Receiver Cable, 15 ft. 8 Conductor 0974 Emitter Cable, 30 ft. 5 Conductor 0973 Receiver Cable, 30 ft. 8 Conductor 9775 Emitter...

Open the catalog to page 7
Light Curtain Catalog - 8

SAFETY INTERFACE MODULES (SIM) All Tapeswitch safety interface controllers (SIM) are compatible with the B-Series light curtains. The emitter and receiver pair, by themselves, constitutes a complete light curtain system, which provides two redundant solid state PNP outputs. Consult factory for correct series for your application. These outputs can be interfaced directly into a machine control circuit, provided that the circuitry is compatible with PNP type outputs supplied from the light curtain’s, (i.e. safety relays, emergency stop relay packages, fail-safe PLC’s, etc.) Care should be...

Open the catalog to page 8
Light Curtain Catalog - 9

SAFETY INTERFACE MODULES (SIM) BSRUA-2 Interface Controller (Part No. 0951) The BSRUA-2 Controller is a DIN rail mount unit capable of interfacing up to two light Curtain sensing units. It will accept an input power source of 110/240 VAC or 24 VDC and provides the necessary power to the light curtain sensing unit emitter and receiver. The two safety outputs follow the state of the light curtain and AUTOMATICALLY resume the “on” state once an obstruction is removed. There is no operator intervention required and no operator power up sequence necessary. The unit contains status and diagnostic...

Open the catalog to page 9
Light Curtain Catalog - 10

SAFETY INTERFACE MODULES (SIM) GDC1 24VDC Power Supply (Part No. 0953) The GDC1 is a compact switching mode power supply and is specifically intended for use with the B-Series light curtain and SRUB, and SRUS interface unit. It provides a regulated 24 VDC supply to the safety equipment (i.e. safety relay and light curtain) from a wide range of AC input voltages. It comes with adapter clips to allow it to be DIN rail mounted. The output voltage is adjustable to account for a variety of loading conditions. BC-Series Blanking Interface Controllers The BC-Series of interface controllers...

Open the catalog to page 10
Light Curtain Catalog - 11

2. Select Cable Assemblies - One each for emitter and receiver. Cable length can be adjusted in the field. a. Determine minimum cable length required for emitter unit. b. Determine minimum cable length required for receiver unit. c. Select the one emitter cable and one receiver cable from the table. Emitter Cable, 15 ft. 5 Conductor 0972 Emitter Cable, 30 ft. 5 Conductor 0973 Emitter Cable, 98 ft. 5 Conductor 0976 Receiver Cable, 15 ft. 8 Conductor 0974 Receiver Cable, 30 ft. 8 Conductor 9975 Receiver Cable, 98 ft. 8 Conductor 0977 3. Select Mounting Brackets - This is optional. Sensing...

Open the catalog to page 11